Sensitivity Analysis of Fluid–Fluid Interfacial Area, Phase Saturation and Phase Connectivity on Relative Permeability Estimation Using Machine Learning Algorithms

Recent studies have shown that relative permeability can be modeled as a state function which is independent of flow direction and dependent upon phase saturation (S), phase connectivity (X), and fluid–fluid interfacial area (A). This study evaluates the impact of each of the three state parameters (S, X, and A) in the estimation of relative permeability. The relative importance of the three state parameters in four separate quadrants of S-X-A space was evaluated using a machine learning algorithm (out-of-bag predictor importance method). The results show that relative permeability is sensitive to all the three parameters, S, X, and A, with varying magnitudes in each of the four quadrants at a constant value of wettability. We observe that the wetting-phase relative permeability is most sensitive to saturation, while the non-wetting phase is most sensitive to phase connectivity. Although the least important, fluid–fluid interfacial area is still important to make the relative permeability a more exact state function.

47 OTHER INSTRUMENTATION↗

Fluid – Fluid Interfacial Area and Its Impact on Relative Permeability - A Pore Network Modeling Study

Abstract Relative permeability (kr) is commonly modeled as an empirical function of phase saturation. Although current empirical models can provide a good match of one or two measured relative permeabilities using saturation alone, they are unable to predict relative permeabilities well when there is hysteresis or when physical properties such as wettability change. Further, current models often result in relative permeability discontinuities that can cause convergence and accuracy problems in simulation. To overcome these problems, recent research has modeled relative permeability as a state function of both saturation (S) and phase connectivity (X). Pore network modeling (PNM) data, however, shows small differences in relative permeability for the same S-X value when approached from a different flow direction. This paper examines the impact of one additional Minkowski parameter (Mecke and Arns, 2005), the fluid-fluid interfacial area, on relative permeability to identify if that satisfactorily explains this discrepancy. We calculate the total fluid-fluid interfacial areas (IA) during two-phase (oil/water) flow in porous media using pore network modeling. The area is calculated from PNM simulations using the areas associated with corners and throats in pore elements of different shapes. The pore network is modeled after a Bentheimer sandstone, using square, triangular, and circular pore shapes. Simulations were conducted for numerous primary drainage and imbibition cycles at a constant contact angle of 0° for the wetting phase. Simultaneous measurements of capillary pressure, relative permeability, saturation, and phase connectivity are made for each displacement. Fluid-fluid interfacial area is calculated from the PNM capillary pressure, the fluid location in the pore elements, and the pore element dimensional data. The results show that differences in the relative permeability at the same (S,X) point is explained well by differences in the fluid-fluid interfacial area (IA). That is, for a larger change in IA at these intersection points, the permeability difference is greater. That difference in relative permeability approaches zero as the difference in IA approaches zero. This confirms that relative permeability can be modeled better as a unique function of S, X, and IA. The results also show that an increase in IA restricts flow decreasing the nonwetting (oil) phase permeability. This decrease is caused by an increase in the throat area fraction compared to the corner area as the total area IA increases. The wetting phase relative permeability, however, shows the inverse trend, in that its relative permeability is greater when IA becomes larger owing to a greater fraction of the total area associated with the corners. The area IA, however, impacts the nonwetting phase relative permeability more than the wetting phase relative permeability. Corner flow improves the wetting phase relative permeability because the wetting phase is continuous there. Finally, a sensitivity analysis shows that relative permeability a is more sensitive to change in S than they are for IA for the case studied implying that if only two parameters are used to model relative permeability it is better to choose S and X.

Engineering↗

Modeling Contact Angle vs. Temperature for the Quartz-Water-Decane System

Innovative approaches are needed to improve the efficiency of oil recovery technologies to meet the growing demands of fossil-fuel based energy consumption. Enhanced oil recovery (EOR) methods such as low-salinity waterflooding and chemically tuned waterflooding aim to optimize the reservoir’s wetting properties, detaching oil globules from rock surfaces and allowing easier oil flow through pore throats. This wetting behavior is commonly quantified by contact angle measurements of the rock-oil-brine interface, which have been thoroughly investigated and theorized for many systems at ambient temperatures and pressures. However, few studies exist for extending contact angle theories away from ambient conditions. In this paper, we model the contact angles of a quartz-water-decane system at elevated temperatures using the surface tension component (STC) approach. Temperature-dependent van der Waals [Lifshitz-van der Waals (LW)] interactions and hydrogen-bonding (acid-base) interactions were calculated and are incorporated into the model for the quartz-water-decane interface. Additionally, the Hough and White procedure was used to create temperature-dependent dielectric functions of quartz, water, and normal decane for calculations of Hamaker coefficients. Hamaker coefficients calculated this way are highly linear with temperature and agree well with Israelachvili’s approximation. The acid-base interactions likely contribute the most to system wettability changes. Resulting contact angles of the quartz-water-decane system shift from water-wet (16°) to slightly water-wet (57.4°) as temperature increases. The model was also successfully verified for the quartz-air-water system. Our results can be used in future studies to determine optimal injected water compositions for specific rock-oil-brine and other systems with consideration of reservoir temperature.

02 PETROLEUM↗