Search NASASearch

Engineering topics

Johnson, David G.

Publications and source records attributed to Johnson, David G..

22 records · Page 2

Stratospheric spectroscopy with the far-infrared spectrometer (FIRS-2) - Overview and recent results

The Smithsonian Astrophysical Observatory's program of balloon-borne stratospheric spectroscopic measurements is described, including instrumentation, recent scientific results, and future plans. The design and operation of the FIRS-2 far-infrared spectrometer is discussed. The current status of our efforts to recover mixing-ratio profiles with about 1 percent precision is presented. Representative recent results are shown giving mixing-ratio profiles from 20 to 50 km, selected from the suite HOCl, HCl, HF, NO2, N2O, HNO3, OH, HO2, H2O2, H2O (and isotopes), O2 (and isotopes), O3 (and isotopes), and CO2 (and isotopes). The utility of O2 and CO2 spectral lines for information on view angle or temperature and pressure is discussed. Future plans are mentioned, including the use of FIRS-2 on a balloon platform for UARS correlative measurements, the use of FIRS-2 on the NASA DC-8 platform for polar measurements, and the potential benefits of a FIRS instrument on a Shuttle platform.

Traub, Wesley A.

Stratospheric hydroperoxyl measurements

The hydroperoxyl radical plays a key role in stratospheric chemistry through the HO(x) catalytic cycle of ozone destruction. Earlier measurements of stratospheric HO2 have given mixed results. Some measured mixing ratios greatly exceed theoretical predictions. Measurements of HO2 have now been made with a balloon-borne FIR spectrometer. The measured daytime profile is in excellent agreement with theory up to 40 kilometers. Above this level the measurements exceed theory by 30 percent, perhaps because of underprediction of ozone at these altitudes. The nighttime HO2 profile is strongly depressed with respect to the daytime profile, in general agreement with theory.

Traub, Wesley A.

A 1 percent measurement of the temperature of the cosmic microwave radiation at lambda = 1.2 centimeters

Results are reported of a direct measurement of the cosmic microwave radiation temperature using a special Dicke radiometer (wavelength = 1.2 cm) designed to minimize the usual systematic errors. The experiment was performed at balloon altitudes to avoid atmospheric emission. The first flight gives a cosmic microwave radiation temperature of 2.783 + or - 0.025 K, where the error is due to several errors (mostly systematic) added by quadrature. This is the most accurate direct measurement (by a factor of 3) yet reported.

Johnson, David G.

Increased response to insulin of glucose metabolism in the 6-day unloaded rat soleus muscle

Hind leg muscles of female rats were unloaded by tail cast suspension for 6 days. In the fresh-frozen unloaded soleus, the significantly greater concentration of glycogen correlated with a lower activity ratio of glycogen phosphorylase (p less than 0.02). The activity ratio of glycogen synthase also was lower (p less than 0.001), possibly due to the higher concentration of glycogen. In isolated unloaded soleus, insulin (0.1 milliunit/ml) increased the oxidation of D(U-C-14) glucose, release of lactate and pyruvate, incorporation of D-(U-C-14) glucose into glycogen, and the concentration of glucose 6-phosphate more (p less than 0.05) than in the weight-bearing soleus. At physiological doses of insulin, the percent of maximal uptake of 2-deoxy-D-(1,2-H-3) glucose/muscle also was greater in the unloaded soleus. Unloading of the soleus increased, by 50 percent the concentration of insuling receptors, due to no decrease in total receptor number during muscle atrophy. This increase may account for the greater response of glucose metabolism to insulin in this muscle. The extensor digitorum longus, which generally shows little response to unloading, displayed no differential response of glucose metabolism to insulin.

Henriksen, Erik J.