Search NASA⌕ Search

Engineering topics

Johnson, E

Publications and source records attributed to Johnson, E.

SU-F-T-424: Mitigation of Increased Surface Dose When Treating Through A Carbon Fiber Couch Top

Purpose: To study the effect of the Varian carbon fiber couch top on surface dose for patients being treated using single PA beams in the supine position and to identify simple methods for surface dose reduction. Methods: Measurements of surface dose were obtained in Solid Water phantoms using both a parallel plate ionization chamber (PTW Advanced Markus) and EBT2 Radiochromic films for both 6 and 10MV photons. All measurements were referenced to a depth considered a typical for PA Spine fields. Techniques used to reduce the surface dose included introducing an air standoff using Styrofoam sheets to suspend the phantom surface above the couch top and by adding a thin high Z scattering foil on the table surface. Surface doses were evaluated for typical field sizes, standoff heights, and various scattering materials. Comparisons were made to the surface dose obtainable when treating through a Varian Mylar covered tennis racket style couch top. Results: Dependence on typical spine field sizes was relatively minor. Dependence on air gap was much more significant. Surface doses decreased exponentially with increases in air standoff distance. Surface doses were reduced by approximately 50% for an air gap of 10cm and 40% for a 15cm air gap. Surface doses were reduced by an additional 15% by the addition of a 1mm Tin scattering foil. Conclusion: Using simple techniques, it is possible to reduce the surface dose when treating single PA fields through the Varian carbon fiber couch top. Surface doses can be reduced to levels observed when treating though transparent Mylar tops by adding about 15 cm of air gap. Further reductions are possible by adding thin scattering foils, such as Tin or Lead, on the couch surface. This is a low cost approach to reduce surface dose when using the Varian carbon fiber couch top.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-78: A Study of Dose Falloff Gradient in RapidArc Planning of Lung SBRT

Purpose: Rapid dose falloff beyond PTV is an important criterion for normal tissue sparing in SBRT. RTOG protocols use D2cm and R50% for plan quality evaluation. This study is aimed at analyzing the dose falloff gradient beyond the PTV extending into normal tissue structures and to ascertain the impact of PTV geometry and location on the dose falloff gradient in RapidArc planning of lung SBRT Methods: In this retrospective study, we analyzed 39 clinical RapidArc lung SBRT treatment plans that met RTOG-0915 criteria. Planning was done on Eclipse 8.9 for delivery on either Novalis NTx or TrueBeam STx equipped with HD MLCs. PTV volumes ranged between 5.3 and 113 cc (2.2 to 6 cm sphere equivalent diameter respectively) and their geographic locations were distributed in both lungs. 6X, 6X-FFF, 10X, and 10X-FFF energies were used for planning. All of these SBRT plans were planned using either 2 or 3 full or hemi arcs, with moderate couch kicks. Dose falloff gradients were obtained by generating 7 concentric 5 mm rings beyond PTV surface. Mean dose in each ring is used to evaluate percentage dose falloff gradient as a function of distance from the PTV surface. Results: The mean percentage dose falloff beyond PTV surface in all plans followed an exponential decay and the data was modeled with double exponential decay fit. Photon energy selection in the plan had a minimal impact on the mean percentage dose fall off beyond PTV surface. Conclusion: Dose falloff beyond PTV surface as a function of distance can be ascertained by the use of the double exponential decay fit coefficients in RapidArc planning of lung SBRT. This will help also in plan quality evaluation in addition to D2cm and R50% defined by RTOG.

60 APPLIED LIFE SCIENCES↗

Measurement of {sup 17}F+p reactions at RESOLUT

The {sup 14}O({alpha},p){sup 17}F reaction is important for understanding the {alpha}p process that occurs in X-ray bursts, but the rate of this reaction remains uncertain due to the uncertain properties of states in {sup 18}Ne. We measured the {sup 17}F(p,p){sup 17}F and {sup 17}F(p,{alpha}){sup 14}O reactions to study the properties of states in {sup 18}Ne that are important for the {sup 14}O({alpha},p){sup 17}F reaction using {sup 17}F radioactive beams from the RESOLUT facility at Florida State University. Double-sided silicon strip detectors were used to detect light particles, and recoiling heavy ions were detected in coincidence using a gas ionization chamber at forward angles. The performance of the system was first tested using the {sup 17}O(p,{alpha}){sup 14}N reaction. This was the first measurement using the ASIC electronics and recoil detector being developed for the Array for Nuclear Astrophysics Studies with Exotic Nuclei (ANASEN). We report on the performance and preliminary results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PROGRESS WITH NSLS-II INJECTION STRAIGHT SECTION DESIGN

The NSLS-II injection straight section (SR) consists of pulsed and DC bumps, septa system, beam trajectory correction and diagnostics systems. In this paper we discuss overall injection straight layout, preliminary element designs, specifications for the pulsed and DC magnets and their power supplies, vacuum devices and chambers and diagnostics devices. Prior to selecting the current 'conventional' design of the injection straight section we analyzed an option of injection via pulsed multipole pioneered at PF-AR. We found that this promising approach was not suited to the NSLS-II storage ring optics, since it would require a impractically compact arrangement of the injection straight section components and a complex modification of the transport line optics due to the strong focusing of the injected beam passing off the pulsed multipole axis. In addition, the requirement for a small injection transient of the stored beam orbit severely constrains the vertical alignment tolerance of the pulsed multipole. The design of the NSLS-II injection straight section is now completed with exception of transition chamber details, which will be adjusted to accommodate the actual layouts of the pulsed magnets.

43 PARTICLE ACCELERATORS↗

High current SRF cavity design for SPL and eRHIC

A high current five-cell Nb superconducting cavity, called BNL3 cavity, was optimized and designed for the SPL and eRHIC. For the fundamental mode, the optimization process aimed at maximizing the R/Q of the fundamental mode and the geometry factor G under an acceptable RF field ratio level of B{sub peak}/E{sub acc} and E{sub peak}/E{sub acc}. For higher order modes, the optimization is to lower (R/Q)Q{sub ext} for dipole and quadrupole modes to suppress the beam-break-up (BBU). To extract the HOM power out of the cavity, the BNL3 cavity employs a larger beam pipe, allowing the propagation of HOMs, but not the fundamental mode. Six HOM couplers (three at each end) are used to extract large HOM power. To avoid the cross-talk between cavities, tapers are employed between the cavities. This paper presents the design of the BNL3 cavity, end groups and BBU simulation results.

43 PARTICLE ACCELERATORS↗

New HOM coupler design for high current SRF cavity

Damping higher order modes (HOMs) significantly to avoid beam instability is a challenge for the high current Energy Recovery Linac-based eRHIC at BNL. To avoid the overheating effect and high tuning sensitivity, current, a new band-stop HOM coupler is being designed at BNL. The new HOM coupler has a bandwidth of tens of MHz to reject the fundamental mode, which will avoid overheating due to fundamental frequency shifting because of cooling down. In addition, the S21 parameter of the band-pass filter is nearly flat from first higher order mode to 5 times the fundamental frequency. The simulation results showed that the new couplers effectively damp HOMs for the eRHIC cavity with enlarged beam tube diameter and 2 120{sup o} HOM couplers at each side of cavity. This paper presents the design of HOM coupler, HOM damping capacity for eRHIC cavity and prototype test results.

43 PARTICLE ACCELERATORS↗

Beam break-up estimates for the ERL at BNL

A prototype Ampere-class superconducting energy recovery linac (ERL) is under advanced construction at BNL. The ERL facility is comprised of a five-cell SC Linac plus a half-cell SC photo-injector RF electron gun, both operating at 703.75 MHz. The facility is designed for either a high-current mode of operation up to 0.5 A at 703.75 MHz or a high-bunch-charge mode of 5 nC at 10 MHz bunch frequency. The R&D facility serves a test bed for an envisioned electron-hadron collider, eRHIC. The high-current, high-charge operating parameters make effective higher-order-mode (HOM) damping mandatory, and requires the determination of HOM tolerances for a cavity upgrade. The niobium cavity has been tested at superconducting temperatures and has provided measured quality factors (Q) for a large number of modes. These numbers were used for the estimate of the beam breakup instability (BBU). The facility will be assembled with a highly flexible lattice covering a vast operational parameter space for verification of the estimates and to serve as a test bed for the concepts directed at future projects.

43 PARTICLE ACCELERATORS↗

Calibration of the ERL cavity FPC and PU couplers

The performance parameters of a superconducting cavity, notably accelerating field and quality factor, are first obtained in a cryogenic vertical test Dewar, and again after the final assembly in its cryostat. The tests involve Network Analyzer (NA) measurements in which the cavity is excited through an input coupler and the properties are obtained from the reflected signal at the input and the transmitted signal from the output coupler. The interpretation of the scattering coefficients in terms of field strength requires the knowledge of the Fundamental Power Coupler (FPC) and Pick-Up (PU) coupler strength, as expressed by their 'external' and Q{sub FPC} Q{sub PU}. The coupler strength is independent of the field level or cavity losses and thus can be determined at low levels with the scattering coefficients S{sub 11} and S{sub 21}, assuming standard 50 {Omega} terminations in the network analyzer. Also needed is the intrinsic cavity parameter, R{sub a} /Q{sub 0} {triple_bond} {l_brace}R/Q{r_brace}, a quantity independent of field or losses which must be obtained from simulation programs, such as the Microwave Studio.

43 PARTICLE ACCELERATORS↗

The High-Affinity E. Coli Methionine ABC Transporter: Structure And Allosteric Regulation

The crystal structure of the high-affinity Escherichia coli MetNI methionine uptake transporter, a member of the adenosine triphosphate (ATP)-binding cassette (ABC) family, has been solved to 3.7 angstrom resolution. The overall architecture of MetNI reveals two copies of the adenosine triphosphatase (ATPase) MetN in complex with two copies of the transmembrane domain MetI, with the transporter adopting an inward-facing conformation exhibiting widely separated nucleotide binding domains. Each MetI subunit is organized around a core of five transmembrane helices that correspond to a subset of the helices observed in the larger membrane-spanning subunits of the molybdate (ModBC) and maltose (MalFGK) ABC transporters. In addition to the conserved nucleotide binding domain of the ABC family, MetN contains a carboxyl-terminal extension with a ferredoxin-like fold previously assigned to a conserved family of regulatory ligand-binding domains. These domains separate the nucleotide binding domains and would interfere with their association required for ATP binding and hydrolysis. Methionine binds to the dimerized carboxyl-terminal domain and is shown to inhibit ATPase activity. These observations are consistent with an allosteric regulatory mechanism operating at the level of transport activity, where increased intracellular levels of the transported ligand stabilize an inward-facing, ATPase-inactive state of MetNI to inhibit further ligand translocation into the cell.

36 MATERIALS SCIENCE↗

Microbial Communities in Subpermafrost Saline Fracture Water at the Lupin Au Mine, Nunavut, Canada

We report the first investigation of a deep subpermafrost microbial ecosystem, a terrestrial analog for the Martian subsurface. Our multidisciplinary team analyzed fracture water collected at 890 and 1,130 m depths beneath a 540-m-thick permafrost layer at the Lupin Au mine (Nunavut, Canada). 14C, 3H, and noble gas isotope analyses suggest that the Na Ca Cl, suboxic, fracture water represents a mixture of geologically ancient brine, ~25-kyr-old, meteoric water and a minor modern talik-water component. Microbial planktonic concentrations were ~103 cells mL 1. Analysis of the 16S rRNA gene from extracted DNA and enrichment cultures revealed 42 unique operational taxonomic units in 11 genera with Desulfosporosinus, Halothiobacillus, and Pseudomonas representing the most prominent phylotypes and failed to detect Archaea. The abundance of terminally branched and midchain-branched saturated fatty acids (5 to 15 mol%) was consistent with the abundance of Grampositive bacteria in the clone libraries. Geochemical data, the ubiquinone (UQ) abundance (3 to 11 mol%), and the presence of both aerobic and anaerobic bacteria indicated that the environment was suboxic, not anoxic. Stable sulfur isotope analyses of the fracture water detected the presence of microbial sulfate reduction, and analyses of the vein-filling pyrite indicated that it was in isotopic equilibrium with the dissolved sulfide. Free energy calculations revealed that sulfate reduction and sulfide oxidation via denitrification and not methanogenesis were the most thermodynamically viable consistent with the principal metabolisms inferred from the 16S rRNA community composition and with CH4 isotopic compositions. The sulfate-reducing bacteria most likely colonized the subsurface during the Pleistocene or earlier, whereas aerobic bacteria may have entered the fracture water networks either during deglaciation prior to permafrost formation 9,000 years ago or from the nearby talik through the hydrologic gradient created during mine dewatering. Although the absence of methanogens from this subsurface ecosystem is somewhat surprising, it may be attributable to an energy bottleneck that restricts their migration from surface permafrost deposits where they are frequently reported. These results have implications for the biological origin of CH4 on Mars.

54 ENVIRONMENTAL SCIENCES↗

A Miniature Solid-State Spectrometer for Space Applications: Field Tests

A solid state infrared spectrometer has been developed under the Planetary Instrument Definition and Development Program PIDDP to implement a small rugged spectrometer principally for landed applications. The instrument uses the high index of refraction and waveguide properties of a silicon slab to achieve good spectral resolution and high throughput in a small instrument footprint (less than 25 cm). Light enters the silicon slab and is reflected off a grating (Ebert configuration), utilizing the silicon index of refraction to achieve high dispersion. An array of microthermopiles is used to measure the amplitude of the dispersed light. Input optics are typically utilized to focus light on the input aperture and a chopper is used to compensate system drift.

Smythe, W. D.↗