Aerothermal modeling program, phase 1

Aerothermal submodels used in analytical combustor models are analyzed. The models described include turbulence and scalar transport, gaseous full combustion, spray evaporation/combustion, soot formation and oxidation, and radiation. The computational scheme is discussed in relation to boundary conditions and convergence criteria. Also presented is the data base for benchmark quality test cases and an analysis of simple flows.

Srinivasan, R.

Aerothermal modeling program, phase 1

The combustor performance submodels for complex flows are evaluated. The benchmark test cases for complex nonswirling flows are identified and analyzed. The introduction of swirl into the flow creates much faster mixing, caused by radial pressure gradients and increase in turbulence generation. These phenomena are more difficult to predict than the effects due to geometrical streamline curvatures, like the curved duct, and sudden expansion. Flow fields with swirl, both confined and unconfined are studied. The role of the dilution zone to achieve the turbine inlet radial profile plays an important part, therefore temperature field measurements were made in several idealized dilution zone configurations.

Srinivasan, R.

Radiative and free convective heat transfer from a containerless sphere

A mathematical model is derived for heat loss due to radiation and free convection for a small copper sphere (approximately 0.3 to 0.4 cm diameter) cooled by a helium-argon gas mixture. A FORTRAN program written to simplify calculations and extend the range of applicability to experimentation is presented. Pressures used were less than 400 torr, and resulting temperatures ranged from 500 to 4600 K. Comparison of results for initial cooling by the gas mixture with experimental data showed a 5 percent error for temperature values and a 2.7 percent error for the temperature difference caused by the cooling. Results indicate that the accuracy could be increased significantly by using better estimates for thermal conductivities.

Johnson, K.