Search NASASearch

Engineering topics

Johnson, Kenneth R.

Publications and source records attributed to Johnson, Kenneth R..

Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

Fluorescence

RESOLVE - Starting Point for Partnerships in Lunar and Mars Resource Characterization

The mystery and controversy surrounding the possibility of finding water/ice at the lunar poles of the Moon based on the interpretation of neutron spectrometer data from Lunar Prospector and radar data from Clementine raises questions that both Science and the Human Exploration proponents want answered. From the Science perspective, the determination of lunar volatiles and in particular the increased hydrogen concentration detected at the lunar poles was identified as an important objectives for lunar exploration and understanding the history of the Moon, Sun, and the solar system. From the Human Exploration perspective, the potential for large concentrations of accessible water opens up possibilities for utilizing in-situ resources, known as In-Situ Resource Utilization (ISRU), to implement a sustained and affordable human exploration program of the Moon and beyond through production of propellants, fuel cell reagents, and life support consumables for lunar surface operations and mobility, and Earth-Moon transportation. Both the Science and Human Exploration proponents agree that a mission to the lunar poles to obtain ground truth data is the only means to conclusively answer the questions of whether water/ice exists, how much, what form, and where did it come from. In 2005, NASA initiated the Regolith and Environment Science & Oxygen and Lunar Volatiles Extraction (RESOLVE) project, and is currently developing hardware under the NASA Exploration Technology Development Program (ETDP). The purpose of the project was to begin developing technologies and operations that would answer the fundamental science questions, such as What resources are available on the Moon, where are they, what form, and where did they come from? as well as critical engineering questions, such as How will we mine these resources, what chemical extraction processes are the most practical and efficient, and what are the engineering challenges to be faced in this environment? .

Sanders, Gerald B.

The 2001 Mars In-Situ-Propellant-Production Precursor (MIP) Flight Demonstration

The successful performance of the five individual demonstrations of MARS IN-SITU-PROPELLANT-PRODUCTION PRECURSOR (MIP) will provide both knowledge of and confidence in the reliability of this technology. At the completion of this flight demonstration, the MIP Team will be able to: a) recommend preferred hardware configurations for the intake and adsorption of carbon dioxide from the Martian atmosphere; b) understand the performance characteristics of zirconia cells to generate propellant-grade oxygen; c) understand long-term performance characteristics of advanced solar cells/arrays operated in the actual Mars environment; d) evaluate the functionality of methods to mitigate the deposition of airborne dust onto solar arrays; and e) recommend preferred hardware designs for innovative thermal management including the radiation of heat to the outside environment.

Kaplan, David I.

Mars Pathfinder Spacecraft, Lander, and Rover Testing in Simulated Deep Space and Mars Surface Environments

The Mars Pathfinder (MPF) Spacecraft was built and tested at the Jet Propulsion Laboratory during 1995/96. MPF is scheduled to launch in December 1996 and to land on Mars on July 4, 1997. The testing program for MPF required subjecting the mission hardware to both deep space and Mars surface conditions. A series of tests were devised and conducted from 1/95 to 7/96 to study the thermal response of the MPF spacecraft to the environmental conditions in which it will be exposed during the cruise phase (on the way to Mars) and the lander phase (landed on Mars) of the mission. Also, several tests were conducted to study the thermal characteristics of the Mars rover, Sojourner, under Mars surface environmental conditions. For these tests, several special test fixtures and methods were devised to simulate the required environmental conditions. Creating simulated Mars surface conditions was a challenging undertaking since Mars' surface is subjected to diurnal cycling between -20 C and -85 C, with windspeeds to 20 m/sec, occurring in an 8 torr CO2 atmosphere. This paper describes the MPF test program which was conducted at JPL to verify the MPF thermal design.

Johnson, Kenneth R.

Graphic Three-Axes Presentation of Residual Gas Analyzer Data

Residual gas analyzers (RGA) are commonly used to measure the composition of residual gases in thermal-vacuum test chambers. Measurements from RGA's are often used to identify and quantify outgassing contaminants from a test article during thermal-vacuum testing. RGA data is typically displayed as snapshots in time, showing instantaneous concentrations of ions from ionized residual gas molecules at different atomic masses. This ion concentration information can be interpreted to be representative of the composition of the residual gas in the chamber at the instant of analysis. Typically, test personnel are most interested in tracking the time history of changes in the composition of chamber residual gas to determine the relative cleanliness and the clean-up rate of the test article under vacuum. However, displays of instantaneous RGA data cannot provide test personnel with the preferred time history information. In order to gain an understanding of gas composition trends, a series of plots of individual data snapshots must be analyzed. This analysis is cumbersome and still does not provide a very satisfactory view of residual gas composition trends. A method was devised by the authors to present RCA data in a three-axis format, plotting Atomic Mass Unit (AMU), the Ionization Signal Response (ISR) as amps/torr as a function of AMU, and Time, to provide a clear graphic visualization of trends of changes in ISR with respect to time and AMU (representative of residual gas composition). This graphic visualization method provides a valuable analytical tool to interpret test article outgassing rates during thermal vacuum tests. Raw RGA data was extracted from a series of delimited ASCII files and then converted to a data array in a spreadsheet. Consequently, using the 3-D plotting functionality provided by the spreadsheet program, 3-D plots were produced. After devising the data format conversion process, the authors began developing a program to provide real-time 3-D plotting of RGA data. The intent of this program is to automate the RGA data acquisition process and to generate up-to-the-minute time history 3-D displays of stored RGA data (development of this program was not complete at the time of this writing). This paper provides a brief description of the data format conversion process and presents results from a recent test to illustrate the usefulness of this 3-D RGA data plotting technique.

Johnson, Kenneth R.

Graphic Three-Axes Presentation of Residual Gas Analyser Data

Residual gas analyzers (RGA) are commonly used to measure the composition of residual gases in thermal-vacuum test chambers. Measurements from RGAs are often used to identify and quantify outgassing contaminants from a test article during thermal-vacuum testing. RGA data is typically displayed as snapshots in time, showing instantaneous concentrations of ions from ionized residual gas molecules at different atomic masses. A method was devised by the authors to present RGA data in a three-axis format, plotting atomic mass unit (AMU), ion concentration as a function of AMU, and time, to provide a clear graphic visualization ot trends in gas concentration changes and to initiate a valuable analytical tool to interpret test article outgassing rates during thermal-vacuum testing.

data analysis

Improved Bakeout Chambers Within Vacuum Chambers

Improved bakeout chamber incorporates hardware features that, in conjunction with improved bakeout procedure, reduce spurious contamination and increase accuracy of contamination measurements. When operated according to revised bakeout procedure, they yield measurements of contamination on vacuum-bake test articles more accurate than available previously, and potential for post-bake recontamination of vacuum-baked articles reduced. These chambers improved versions of one described in "Bakeout Chamber Within Vacuum Chamber" (NPO-18959). By enclosing test article in enclave and keeping walls of enclave hotter than test article during bakeout, one prevents condensation of contaminants on inner walls of enclave.

Johnson, Kenneth R.

Alternate method for achieving temperature control in the -160 to +90 Celcius range

A single-pass method for accurate and precise temperature control in the -160 to +90 C range is discussed. The method exhibited minimal set-point overshoot during temperature transitions. Control to +/-2 C with transitions between set-points of 7 C per minute were achieved. The method uses commercially available temperature controllers and a gaseous nitrogen/liquid nitrogen mixer to dampen the amplitude of cold temperature spikes caused by liquid nitrogen pulsing.

Johnson, Kenneth R.

Apparatus Regulates Temperature Between -170 And 100 Degrees C

Temperature-control apparatus mixes pulses of liquid nitrogen into smoothly flowing nitrogen gas to produce flow of nitrogen gas at controlled low temperature. Mixing chamber provides turbulence, thermal mass, and thermal conductance to promote thermal and mechanical mixing of liquid and gaseous flows and thereby suppresses large transient deviations from set-point temperature.

Johnson, Kenneth R.

An alternate method for achieving temperature control in the -130 C to 75 C range

Thermal vacuum testing often requires temperature control of chamber shrouds and heat exchangers within the -130 C to 75 C range. There are two conventional methods which are normally employed to achieve control through this intermediate temperature range: (1) single-pass flow where control is achieved by alternately pulsing hot gaseous nitrogen (GN2) and cold LN2 into the feed line to yield the setpoint temperature; and (2) closed-loop circulation where control is achieved by either electrically heating or LN2 cooling the circulating GN2 to yield the setpoint temperature. A third method, using a mass flow ratio controller along with modulating control valves on GN2 and LN2 lines, provides excellent control but equipment for this method is expensive and cost-prohibitive for all but long-term continuous processes. The single-pass method provides marginal control and can result in unexpected overcooling of the test article from even a short pulse of LN2. The closed-loop circulation method provides excellent control but requires an expensive blower capable of operating at elevated pressures and cryogenic temperatures. Where precise control is needed (plus or minus 2 C), single-pass flow systems typically have not provided the precision required, primarily because of overcooling temperature excursions. Where several individual circuits are to be controlled at different temperatures, the use of expensive cryogenic blowers for each circuit is also cost-prohibitive, especially for short duration of one-of-a-kind tests. At JPL, a variant of the single-pass method was developed that was shown to provide precise temperature control in the -130 C to 75 C range while exhibiting minimal setpoint overshoot during temperature transitions. This alternate method uses a commercially available temperature controller along with a GN2/LN2 mixer to dampen the amplitude of cold temperature spikes caused by LN2 pulsing. The design of the GN2/LN2 mixer, the overall control system configuration, the operational procedure, and the prototype system test results are described.

Johnson, Kenneth R.

A new approach for performing contamination control bakeouts in JPL thermal vacuum test chambers

Contamination control requirements for the Wide Field/Planetary Camera II (WF/PC II) are necessarily stringent to protect against post-launch contamination of the sensitive optical surfaces, particularly the cold charge coupled device (CCD) imaging surfaces. Typically, thermal vacuum test chambers have employed a liquid nitrogen (LN2) cold trap to collect outgassed contaminants. This approach has the disadvantage of risking recontamination of the test article from shroud offgassing during post-test warmup of the chamber or from any shroud warming of even a few degrees during the bakeout process. By using an enclave, essentially a chamber within a chamber, configured concentrically and internally within an LN2 shroud, a method was developed, based on a design concept by Taylor, for preventing recontamination of test articles during bakeouts and subsequent post-test warmup of the vacuum chamber. Enclaves for testing WF/PC II components were designed and fabricated, then installed in three of JPL's Environmental Test Lab chambers. The design concepts, operating procedures, and test results of this development are discussed.

Johnson, Kenneth R.