Search NASA⌕ Search

Engineering topics

Johnson, Nancy

Publications and source records attributed to Johnson, Nancy.

Computer vision models enable mixed linear modeling to predict arbuscular mycorrhizal fungal colonization using fungal morphology

Abstract The presence of Arbuscular Mycorrhizal Fungi (AMF) in vascular land plant roots is one of the most ancient of symbioses supporting nitrogen and phosphorus exchange for photosynthetically derived carbon. Here we provide a multi-scale modeling approach to predict AMF colonization of a worldwide crop from a Recombinant Inbred Line (RIL) population derived from Sorghum bicolor and S. propinquum . The high-throughput phenotyping methods of fungal structures here rely on a Mask Region-based Convolutional Neural Network (Mask R-CNN) in computer vision for pixel-wise fungal structure segmentations and mixed linear models to explore the relations of AMF colonization, root niche, and fungal structure allocation. Models proposed capture over 95% of the variation in AMF colonization as a function of root niche and relative abundance of fungal structures in each plant. Arbuscule allocation is a significant predictor of AMF colonization among sibling plants. Arbuscules and extraradical hyphae implicated in nutrient exchange predict highest AMF colonization in the top root section. Our work demonstrates that deep learning can be used by the community for the high-throughput phenotyping of AMF in plant roots. Mixed linear modeling provides a framework for testing hypotheses about AMF colonization phenotypes as a function of root niche and fungal structure allocations.

59 BASIC BIOLOGICAL SCIENCES↗

Initiating Event Rates at U.S. Nuclear Power Plants: 2022 Update

Analyzing initiating event rates is important because it indicates trends and patterns of plant performance and provides inputs to several U.S. Nuclear Regulatory Commission (NRC) risk-informed regulatory activities. This report presents an analysis of initiating event frequencies at U.S. commercial nuclear power plants from calendar year 1988 through 2022, as reported in licensee event reports. Engineers with nuclear power plant experience reviewed each event report since the last update to this report to categorize and characterize reactor trips. To be included in this study, an event had to meet all of the following criteria: (1) the event included an unplanned reactor trip (not a scheduled reactor trip on the daily operations schedule), (2) the sequence of events started when the reactor was critical and at or above the point of adding heat, (3) the event occurred at a U.S. commercial nuclear power plant (excluding Fort St. Vrain and LaCrosse), and (4) the event was reported by a licensee event report. Sixteen initiating event groupings are trended and displayed. For some of the categories, relevant events are plotted separately for boiling-water reactors (BWR) and pressurized-water reactors (PWR). P-values are given for the possible presence of a trend over the most recent 10 years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Loss-of-Offsite-Power Events: 2021 Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2021, while the most recent 15-year data (i.e., from 2007–2021) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather-related. These categories (and the All-LOOPs group which contains all LOOPs without regarding of the four categories) could be further grouped by whether a LOOP event occurred during critical operation, during shutdown operation, or during all operations. The following decreasing trends in the LOOP occurrence rates were identified for the most recent 10-year period (2012–2021): All-LOOPs during critical operation, switchyard-centered LOOPs during critical operation, and grid-related LOOPs during critical operation. Adverse trends in LOOP durations continue for switchyard-centered LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during shutdown operation for the 1997–2021 period. Statistical tests show the LOOP counts for the period of 2007–2021 are not uniformly distributed across the 12 months, and variation among the months exists for grid-related LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during critical operation. The engineering analysis of LOOP data showed for the period of 2007–2021, the equipment failure events were dominated by failures of relay and other; human errors have been less frequent and occurred primarily in maintenance and switching; and weather were dominated by tornadoes then by lightning and hurricane. Weather was the cause for 45% of LOOPs for the last fifteen years (2007– 2021) but only for 20% of LOOPs for the previous 20 years (1987–2006) .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initiating Event Rates at U.S. Nuclear Power Plants, 2021 Update

Analyzing initiating event rates is important because it indicates trends and patterns of plant performance and provides inputs to several U.S. Nuclear Regulatory Commission (NRC) risk-informed regulatory activities. This report presents an analysis of initiating event frequencies at U.S. commercial nuclear power plants from calendar year 1988 through 2021, as reported in licensee event reports. Engineers with nuclear power plant experience reviewed each event report since the last update to this report to categorize and characterize reactor trips. To be included in this study, an event had to meet all of the following criteria: (1) the event included an unplanned reactor trip (not a scheduled reactor trip on the daily operations schedule), (2) the sequence of events started when the reactor was critical and at or above the point of adding heat, (3) the event occurred at a U.S. commercial nuclear power plant (excluding Fort St. Vrain and LaCrosse), and (4) the event was reported by a licensee event report. Sixteen initiating event groupings are trended and displayed. For some of the categories, relevant events are plotted separately for boiling-water reactors (BWR) and pressurized-water reactors (PWR). P-values are given for the possible presence of a trend over the most recent 10 years. The following trends were identified for the most recent 10 years (2012–2021): • A highly statistically significant decreasing trend was identified for Loss of Offsite Power (p-value = 0.002) • A statistically significant decreasing trend was identified for BWR general transients (p-value = 0.025) • A statistically significant decreasing trend was identified for PWR general transients for the second year in a row (p-value = 0.038).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Loss-of-Offsite-Power Events: Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2020, while the most recent 15-year data (i.e., from 2006–2020) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather related. Highly significant decreasing trends in the LOOP occurrence rates were identified for All-LOOPs during critical operation (p-value = 0.001) and switchyard-centered LOOPs during critical operation (p-value = 0.002) for the most recent 10-year period (2011–2020). Adverse trends in LOOP durations continue for switchyard-centered LOOPs (p-value = 0.005), All-LOOPs (p-value = 0.019), as well as All-LOOPs during shutdown operation (p-value = 0.003). Statistical tests show the LOOP counts are not uniformly distributed across the 12 months, and variation among the months exists for plant-centered LOOPs (p-value = 0.028), grid-related LOOPs (p-value = 0.021), All-LOOPs (p-value = 0.003), and All-LOOPs during critical operation (p-value = 0.008). The engineering analysis of LOOP data showed for the period of 2006–2020, the equipment failure events were dominated by failures of circuits and relay; human errors have been less frequent and occurred primarily in maintenance; and weather events were dominated by tornadoes and lightning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NDMAS System and Process Description

This report provides an overview of the system and its components, defines roles and responsibilities, describes the internal processes that the NDMAS team uses to carry out the mission, and describes hardware and software used by the team.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NDMAS System and Process Description

The U. S. Department of Energy (DOE) has made a significant investment in research to develop the next generation of reactor technologies as well as to improve the performance and lengthen the life cycle of existing nuclear reactors. Data collected to demonstrate new concepts may also be used in the future to support licensing of these technologies. Provenance of these data must be preserved. The Nuclear Data Management and Analysis System (NDMAS) was established to manage and preserve data collected by fuels and materials research conducted by the high-temperature, gas-cooled reactor program. The scope of NDMAS is expanding to include other nuclear research programs that have the shared need to preserve the provenance of research data. Nuclear research funded by DOE is conducted by Idaho National Laboratory (INL), universities, other national laboratories, foreign research partners, and private companies. This research will generate a large amount of data from a variety of sources over a period of many years. Managing the data generated by the research and development projects presents a significant challenge for retaining data integrity and availability.

Analysis of Loss-of-Offsite-Power Events 1987-2018

Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1987 through 2018. LOOP events during critical operation that do not result in a reactor trip are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. No significant trends in critical operation LOOP frequencies over the most recent 10-year period are identified. Adverse trends in LOOP durations are identified for switchyard-centered and grid-related LOOPs, as well as overall LOOPs during critical operation and overall LOOPs during shutdown operation. Both grid-related and weather-related LOOP events are found to show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1987–1996 time period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Loss-of-Offsite-Power Events: 1987-2016

Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1987 through 2016. LOOP events during critical operation that do not result in a reactor trip are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. Emergency diesel generator reliability is also considered (failure to start, failure to load and run, and failure to run more than 1 hour). An adverse trend in overall LOOP frequency is identified. An adverse trend in LOOP durations is identified. Plant-centered and weather-related LOOP events do not show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1986–1996 time period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initiating Event Rates at U.S. Nuclear Power Plants: 1988–2016

Analyzing initiating event rates is important because it indicates performance among plants and also provides inputs to several U.S. Nuclear Regulatory Commission (NRC) risk-informed regulatory activities. This report presents an analysis of initiating event frequencies at U.S. commercial nuclear power plants from calendar year 1988 through 2016 as reported in licensee event reports. Engineers with nuclear power plant experience reviewed each event report since the last update to this report for the presence of valid scrams or reactor trips at power. To be included in the study, an event had to meet all of the following criteria: (1) the event includes an unplanned reactor trip (not a scheduled reactor trip on the daily operations schedule), (2) the sequence of events started when reactor is critical and at or above the point of adding heat, (3) the event occurred at a U.S. commercial nuclear power plant (excluding Fort St. Vrain and LaCrosse), and (4) the event was reported by a licensee event report. Sixteen initiating event groupings are trended and displayed. For some of the categories as relevant initiators are plotted separately for boiling water reactors and pressurized water reactors. P values are given for the possible presence of a trend over the most recent 10 years. Statistically significant decreasing trends were identified for BWR loss of heat sink and general transients.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of functional impact classification on the current U.S. nuclear fleet

Currently, nuclear power generates only a small fraction of the world's electricity, though it does have the potential to meet the needs of the world as long as its production can compete with the alternative energy base load producers. In U.S the commercial nuclear fleet comprises of Light Water Reactors (LWRs), consisting of Pressurized Water Reactors (PWRs) and Boiling Water Reactors (BWRs). Many plants experience multiple events each year, which lead to reactor trips or scrams. This subsequently leads to plants being off the grid, which is not an economically favorable situation in the current energy markets. This study helps identify functional impact (FI) event categories for both PWR's and BWR's. Understanding that not all events and their causes can be anticipated, current industry best practices implement lessons learned to provide challenges and issues identification. In turn these are studied to achieve improved operational practices, and design modifications. This leads to overall enhanced resiliency. FI groups are the categories of initiating events (IE). IEs are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. When a risk cannot be eliminated, IEs are identified and studied to reduce the risk and contribute to the identification of mitigations, safer designs and operational practices. Breaking IE events into groups' results in the classification of FI groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. Inability to remove decay heat from the reactor has the potential to lead to core damage. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. The relationship between FI sequence, and/or frequency per a plant event is outside the scope of this paper. For example, the loss of offsite power (LOOP) can occur from eternal events (i.e. weather, human, wildlife etc.). This results in an event that requires a transfer of power to an emergency source, such as a generator, which produces a reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be LOOP and closure of at least one MSIV in each main steam line. The results presented herein are focused on the analysis and evaluation of FI event categories. Only FI categories that can be found in IE studies, Initialing Events Spreadsheet and are recorded in a historical review of Licensee Event Reports (LERs) from 1988 through 2013. The results of this analysis can support plant decisions, design, procedures, and identify weakness.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

QUANTIFICATION OF FUNCTIONAL IMPACT CLASSIFICATION ON THE CURRENT US NUCLEAR FLEET

Many plants experience multiple failure events each year, and while none of these events result in core damage further consideration for nuclear power plant (NPP) type and its role in an event needs to be considered. Specifically herein initiating events (IE) are considered these are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. Breaking IE failure events into groups results in the classification of functional impact (FI) groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. An example of a FIs is the loss of offsite power (LOOP) from a bird interaction with the power lines. This results in a failure to transfer power to an emergency source, such as a generator, producing a turbine and reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be loss of offsite power and closure of at least one MSIV in each main steam line. The results presented are focused on the analysis and evaluation of FI event categories that can be found in IE studies [1], [2] and the Initialing Events Spreadsheet [3] and is a historical review of Licensee.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗