Search NASA⌕ Search

Engineering topics

Johnson, Tim

Publications and source records attributed to Johnson, Tim.

At least 19 records

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

PFLOTRAN 5

PFLOTRAN leverages massively parallel, high performance computing to simulate large-scale non-isothermal multiphase flow, multicomponent reactive transport and electrical resistivity tomography (ERT) problems in the subsurface environment. Researchers have employed PFLOTRAN to simulate these Earth system processes on leadership class supercomputers for over two decades. The code is designed to predict the future estate of environmental systems and better inform stakeholders in the regulatory decision making process (e.g., fate of contaminants, long-term stewardship for nuclear waste, impact of climate change, etc.). A diverse team of scientists oversees PFLOTRAN development and maintenance under an open-source licensing agreement and manages contributions from an international community of researchers.

Hammond, Glenn↗

EGS Collab Experiment 2: Shear Stimulation ERT Monitoring Data

This repository contains the electrical resistivity tomography (ERT) monitoring data that was collected before, during, and after shear stimulation attempts were conducted at EGS Collab. These tests were carried out on the SURF 4100 level during Experiment 2 in March, 2022. Flow and stimulation data corresponding to this dataset are available in a different GDR dataset, which is linked below. Also included here are the E4D input files that were used to process the ERT data. E4D is an open source ERT monitoring and inversion code which is linked for use below.

15 GEOTHERMAL ENERGY↗

EGS Collab Experiment 2: Distributed Fiber Optic Temperature Data (DTS)

Distributed fiber optic sensing was an important part of the monitoring system for EGS Collab Experiment #2. A single loop of custom fiber package was grouted into the four monitoring boreholes that bracketed the experiment volume. This fiber package contained two multi-mode fibers and four single-mode fibers. These fibers were connected to an array of fiber optic interrogator units, each targeting a different measurement. The distributed temperature system (DTS) consisted of a Silixa XT-DTS unit, connected to both ends of one of the two multi-mode fibers. This system measured absolute temperature along the entire length of fiber for the duration of the experiment at a sampling rate of approximately 10 minutes. This dataset includes both raw data in XML format from the XT-DTS, as well as a processed dataset with the sections of data pertaining only to the boreholes are extracted. We have also included a report that provides all of the relevant details necessary for users to process and interpret the data for themselves. Please read this accompanying report. If, after reading it, there are still outstanding questions, please do not hesitate to contact us. Happy processing.

15 GEOTHERMAL ENERGY↗

Composition and Structure of the EGS Collab Test Bed 1 Based Upon Electrical Resistivity Tomography, Core Compositions, and Wireline Logging

The nature of core from the EGS Collab project was characterized with high resolution XRF analyses on selected core intervals and wireline geophysical logs. Electrical resistivity profiles from the wireline geophysical surveys are consistent with the electrical resistivity tomographic three-dimensional images, and the XRF profiles show elevated levels of sulfur in the vicinity of the interpreted conductivity anomalies. The compositional and wireline logging data are consistent with interpretations from the electrical resistivity tomography data. Based upon these observations the best candidate for the source of the high electrical conductivities is the presence of significant amounts of sulfides within the unit.

Roggenthen, William↗

Riverbed Temperature and 4D ERT Monitoring Reveals Heterogenous Horizontal and Vertical Groundwater-Surface Water Exchange Flows Under Dynamic Stage Conditions

Groundwater surface water exchange plays a critical role in physical, biological, and geochemical function of coastal and riverine systems. Observing exchange flow behavior in heterogeneous systems is a primary challenge, particularly when flows are governed by dynamic river stage or tidal variations. In this paper we demonstrate a novel application of time-lapse 3D electrical resistivity tomography and temperature monitoring where an array of thermistors installed beneath a riverbed double as resistivity electrodes. We use the array to monitor stage driven exchange flows over a 6-day period in a dynamic, stage-driven high order stream. We present a method for addressing the otherwise confounding effects of the moving river-surface boundary on the raw resistivity data, thereby enabling successful tomographic imaging. Temperature time-series at each thermistor location and time-lapse 3D images of changes in bulk electrical conductivity together provide a detailed description of exchange dynamics over a 10-meter by 45-meter section of the riverbed, to a depth of approximately 5 m. Results reveal highly variable flux behavior throughout the monitoring domain including both horizontal and vertical exchange flows.

54 ENVIRONMENTAL SCIENCES↗

Post-remediation geophysical assessment: Investigating long-term electrical geophysical signatures resulting from bioremediation at a chlorinated solvent contaminated site

There is a growing need to assess long-term impacts of active remediation strategies on treated aquifers. A variety of biogeochemical alterations can result from interactions of the amendment with the aquifer, conceivably leading to a geophysical footprint of the long-term alteration of an aquifer. This concept of post-remediation geophysical assessment was investigated in a shallow, chlorinated solvent-contaminated aquifer six to eight years after amendment delivery. Surface resistivity imaging and cross-borehole resistivity and induced polarization (IP) imaging were performed on a transect that spanned treated and untreated zones of the aquifer. Established relationships between IP parameters and surface electrical conductivity were used to predict vertical profiles of electrolytic conductivity and surface conductivity from the inverted cross-borehole images. Aqueous geochemistry data, along with natural gamma and magnetic susceptibility logs, were used to constrain the interpretation. The electrical conductivity structure determined from surface and borehole imaging was foremost controlled by the electrolytic conductivity of the interconnected pore space, being linearly related to fluid specific conductance. The electrolytic conductivity (and thus the conductivity images alone) did not discriminate between treated and untreated zones of the aquifer. In contrast, inverted phase angles and surface conductivities did discriminate between treated and untreated zones of the aquifer, with the treated zone being up to an order of magnitude more polarizable in places. Supporting aqueous chemistry and borehole logging datasets indicate that this geophysical footprint of the long-term impact of the remediation on the aquifer is most likely associated with the formation of polarizable, dispersed iron sulfide minerals. The study opens the door to the possibility of employing time-lapse electrical geophysical measurements to assist with long-term environmental stewardship of legacy sites undergoing active remediation.

bioremediation↗

EGS-Collab Experiment 1: Time-lapse ERT Data and E4D Inversion Files for 10-24-2018 through 11-07-2018 Flow Test

This data submission includes the raw time-lapse ERT (electrical resistivity tomography) monitoring data, flow system data, operator logs, E4D (https://e4d.pnnl.gov) inversion files, and meta-data necessary to reproduce the 4D ERT inversion for the Oct. 24 through Nov. 7 2018 post-stimulation flow test in test bed 1. The tests were done at the Sanford Underground Research Facility at Homestake Mine in South Dakota.

15 GEOTHERMAL ENERGY↗

Panel Session 100: An Integrated Systems-Based Monitoring Approach

This panel focused on recent advancements in monitoring and remaining challenges associated with the implementing cost-effective monitoring approaches for complex DOE sites. Monitoring presents one of the largest, long-term costs for environmental remediation and site stewardship within the DOE because contamination at complex sites will likely be present for tens to hundreds of years into the future. Integration of monitoring with predictive modeling is an approach that can reduce long-term monitoring costs as well as support the effective monitoring design and data interpretation for managing a site toward closure and long-term stewardship. Panelists with presentations: Autonomous Electrical Geophysical Monitoring of Contaminated Sites (Tim Johnson); Systems Based Long-Term Monitoring for DOE Legacy Management (David Shafer); Long-Term Systems Based Monitoring (Anderson Ward)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating Electrical Resistivity Tomography with Vadose Zone Characterization - 20246

The environmental management mission at the U.S. Department of Energy Hanford Site includes addressing subsurface contaminants that are present in the vadose zone because of historical waste discharges. Characterization is needed to support evaluation of whether contaminants at specific disposal sites will migrate to and contaminate the groundwater in the future. Drilling of boreholes and analysis of retrieved sediment samples is a standard approach to evaluating contaminant distribution in the vadose zone for the types of inorganic and radionuclide contaminants at the Hanford Site. However, borehole sampling has limitations for understanding the volumetric distribution of contaminants. The Hanford Site is now applying electrical resistivity tomography to characterize the path and volumetric extent of contaminant migration in the vadose zone. This information aids selection of appropriate locations for obtaining borehole samples and provides three-dimensional contaminant distribution information for incorporation into conceptual site models and to help configure fate and transport models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Uranium Source Treatment Performance Assessment Elements - 20247

Field-scale in situ injection of an aqueous polyphosphate amendment was conducted to decrease uranium leaching from a vadose zone source to groundwater near the Columbia River at the U.S. Department of Energy's Hanford Site. After an initial phase of application in November 2015, this treatment was applied as an enhanced attenuation approach in September 2018, targeting uranium in a subsurface zone where water table periodically rises in response to the seasonal high river stage. Uranium within this zone is aqueous, adsorbed, and in low- and high-solubility precipitates and is mobilized into the groundwater at high river stage, resulting in a persistent groundwater plume. The polyphosphate amendment creates phosphate coatings on uranium (potentially including low solubility uranium-phosphate precipitates) that decrease the uranium leached into groundwater when the zone is periodically rewetted to improve the ability of natural attenuation to meet groundwater concentration objectives. For treatment, the amendment was injected into a network of wells within the periodically rewetted source area. Multiple lines of evidence are being applied to evaluate the performance of the phosphate treatment. Three elements of this performance assessment include 1) identifying the distribution of injected phosphate amendment to the targeted treatment zone using cross-borehole electrical resistivity tomography and comparisons of phosphate precipitates between pre- and post-treatment samples, 2) demonstrating the functional reduction in uranium mobility and leachability using laboratory tests with pre- and post- treatment sediments from the source zone, and 3) evaluating the presence of low-solubility uranium phosphate minerals and/or coatings associated with reduced uranium mobility. (authors)

07 ISOTOPE AND RADIATION SOURCES↗