Search NASA⌕ Search

Engineering topics

Johnston, Christina

Publications and source records attributed to Johnston, Christina.

Revealing in-plane movement of platinum in polymer electrolyte fuel cells after heavy-duty vehicle lifetime

Fuel cell heavy-duty vehicles (HDVs) require increased durability of oxygen-reduction-reaction electrocatalysts, making knowledge of realistic degradation mechanisms critical. Here identical-location micro-X-ray fluorescence spectroscopy was performed on membrane electrode assemblies. The results exposed heavy in-plane movement of electrocatalyst after HDV lifetime, suggesting that electrochemical Ostwald ripening may not be a local effect. Development of local loading hotspots and preferential movement of electrocatalyst away from cathode catalyst layer cracks was observed. The heterogeneous degradation exhibited by a modified cathode gas diffusion layer membrane electrode assembly after HDV lifetime was successfully quantified by the identical-location approach. Further synchrotron micro-X-ray diffraction and micro-X-ray fluorescence experiments were performed to obtain the currently unknown correlation between electrocatalyst nanoparticle size increase and loading change. A direct correlation was discovered which developed only after HDV lifetime. Finally, the work provides a route to engineer immediate system-level mitigation strategies and to develop structured cathode catalyst layers with durable electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic structure manipulation via composition tuning for the development of highly conductive and acid-stable oxides

Exploring materials that simultaneously possess high conductivity and electrochemical stability is critical for various energy-conversion applications. In this study, our combined computations and experiments suggest the Mg–Ti–O chemical space for novel ternary oxide compounds offering high electrical conductivity and corrosion stability in acidic conditions to be potentially used as catalyst supporter of polymer electrolyte membrane fuel cells. High electrical conductivity (6.09 × 10 -1 S cm -1 ) is achieved at room temperature by tuning the chemical composition of Mg 1-x Ti 2+x O 5 while still maintaining good corrosion stability (1.2 × 10 -4 mA cm -2 after six days) in acidic conditions. Furthermore, we discover that a reducing gas environment during the synthesis increases the Ti solubility in Mg 1-x Ti 2+x O 5 with a reduced valence state of Ti, thus resulting in high conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Carbon Corrosion in Polymer Electrolyte Fuel Cells: A Complex Interplay between Morphological Changes and Electrochemical Performance

Due to the high gravimetric energy density of hydrogen, the focus of implementation of polymer electrolyte fuel cells (PEFCs) has shifted from light duty passenger vehicles to heavy duty vehicles such as buses, trucks, locomotives and marine vessels. A mechanistic understanding of degradation is therefore necessary to improve durability and efficiency. During start-up and shut-down (SUSD) of PEFC systems, the catalyst (Pt nanoparticles embedded on carbon support) undergoes local potentials ~ 1 - 1.5 V caused by a combination of fuel (H 2 ) starvation, mixed fuel region and cell reversal. This leads to a series of degradation phenomenon including reduction in cathode catalyst layer (cCL) thickness and porosity, loss in electrochemical surface area (ECSA), ionomer degradation and loss in electrical contact, therefore resulting in severe performance loss. The convoluted relationship between these individual degradation mechanisms, their chronology and their effects on electrochemical performance are yet unresolved. Here, the complex interplay between morphological changes due to carbon corrosion and its effects on the electrochemical performance were analyzed using a combination of detailed electrochemical characterization, spectroscopy, and electron microscopy techniques.

25 ENERGY STORAGE↗

Location-Dependent Cobalt Deposition in Smartphone Cells upon Long-Term Fast-Charging Visualized by Synchrotron X-ray Fluorescence

In this work, we investigate the transition-metal dissolution of the layered cathode material LiCoO 2 upon repeated fast-charging of three smartphone batteries from different manufacturers using synchrotron micro X-ray fluorescence (μ-XRF). Using this spatially resolved technique, dissolution of Co and subsequent location-dependent deposition on the anode are observed. μ-XRF mapping of selected parts of the anode electrode sheets, such as electrode folds and edges of the jelly roll, reveals the difference in the way Co is deposited on specific regions of the anode electrode. While some folds show no depositions, edges of the anode show gradually accumulating Co depositions. Furthermore, careful quantification of the dissolved Co reveals that the capacity loss scales with the amount of deposited Co on the anode, that is, total Co loss from within the cathode. Soft X-ray absorption spectroscopy of the Co depositions on the anode shows that Co is mainly deposited in a reduced 2 + state. While optimization of the fast-charging protocol mitigates Li plating on the anode, no significant difference in the amount of deposited Co can be observed between an optimized and a nonoptimized fast-charging algorithm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Study of Model-Based Protective Fast-Charging and Associated Degradation in Commercial Smartphone Cells: Insights on Cathode Degradation as a Result of Lithium Depositions on the Anode

The ever expanding mobile consumer electronic market has accelerated the need for safe and efficient fast-charging approaches that improve the overall speed of battery charging without hastened deterioration of the battery performance. Herein, the impact of a resource inexpensive, physics-based, electrochemically optimized fast-charging algorithm (charging time < 2 h) for mobile devices is investigated. A critical difference in the amount and morphology of lithium deposits on the anode for cells fast-charged without an optimized algorithm is observed and found to be the main cause of capacity decay. Furthermore, an in-depth study of the LiCoO 2 cathode regions opposite to pronounced lithium deposits on the anode reveals a “mirroring” phenomenon, i.e., a frozen monoclinic phase, and inactivity to relithiation. In operando hard X-ray absorption spectroscopy reveals that degraded spots on harvested cathodes seem to be activated again and participate in the intercalation process when lithiated at low rates from lithium foil counter electrodes. On the other hand, tests at higher C-rates, closer to the actual fast-charging rate, reveal only negligible oxidation state changes and therefore poor performance.

25 ENERGY STORAGE↗