Heatshield for Extreme Entry Environment Technology (HEEET) Thermal Protection System (TPS)

Starting in 2013 and completing in 2019, the Heatshield for Extreme Entry Environment Technology (HEEET) project has been working to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations with extreme entry environments such as Venus, Saturn, Uranus, Neptune and high-speed sample return missions to Earth. A key aspect of the project has been the building and testing of a 1-meter base diameter Engineering Test Unit (ETU) representative of what could be used for a Saturn probe. This paper provides a high-level overview of the HEEET project including manufacturing and testing of the ETU for structural model verification, establish system capability and verify manufacturing workmanship.

Extreme Entry Environment

Validation of Floating Node Method Using Three-Point Bend Doubler Under Quasi-Static Loading

The NASA Advanced Composite Project (ACP), an industry/government/university partnership, has embarked upon the task of developing technology that can aid in reducing the time line for structural certification of aircraft composite parts using a combination of technologies, one of which is high fidelity damage progression computational methods. Phase II of this project included a task for validating an approach based on the Floating Node Method combined with Directional Cohesive Elements (FNM-DCZE). This paper discusses predicted damage onset and growth in a three-point bend doubler specimen compared to experimental results. Sensitivity of the simulations to mesh refinement as well as key material properties and thermal effects are studied and reported. Overall, qualitative results suggest the main aspects of the damage progression have been captured, with the simulated damage morphology and sequence of events resembling closely what was observed experimentally. Quantitatively, the first load-peak is predicted. However, the re-loading observed in the experiments, after the first load peak, is not captured numerically, suggesting further investigation may be worth pursuing.

Selvarathinam, Alex S.

Optical Method for Detecting Displacements and Strains at Ultra-High Temperatures During Thermo-Mechanical Testing

An ultra-high temperature optical method incorporates speckle optics for sensing displacement and strain measurements well above conventional measurement techniques. High temperature pattern materials are used which can endure experimental high temperature environments while simultaneously having a minimum optical aberration. A purge medium is used to reduce or eliminate optical distortions and to reduce, and/or eliminate oxidation of the target specimen.

Smith, Russell W.

Notched Strength Allowables and Inplane Shear Strength of AS4/VRM-34 Textile Laminates

Notched and unnotched strength allowables were developed for a textile composite to provide input data to analytical structural models based on the Pultruded Rod Stiffened Efficient Unitized Structure (PRSEUS) concept. Filled-hole tensile strength, filled-hole compressive strength, and inplane shear strength along stitch lines have been measured. The material system evaluated in this study is based on warp-knitted preforms of AS4 carbon fibers and VRM-34 epoxy resin, which have been processed via resin infusion and oven curing. All specimens were tested in as-fabricated (dry) condition. Filled-hole strengths were evaluated with and without through-thickness stitching. The effects of scaling on filled-hole tensile strength were evaluated by testing specimens in two widths, but with identical width / hole-diameter ratios. Inplane shear specimens were stitched in two configurations, and two specimen thicknesses were tested for each stitch configuration.

Grenoble, Ray W.

Mode II Interlaminar Fracture Toughness and Fatigue Characterization of a Graphite Epoxy Composite Material

Mode II interlaminar fracture toughness and delamination onset and growth characterization data were generated for IM7/8552 graphite epoxy composite materials from two suppliers for use in fracture mechanics analyses. Both the fracture toughness testing and the fatigue testing were conducted using the End-notched Flexure (ENF) test. The ENF test for mode II fracture toughness is currently under review by ASTM as a potential standard test method. This current draft ASTM protocol was used as a guide to conduct the tests on the IM7/8552 material. This report summarizes the test approach, methods, procedures and results of this characterization effort.

O'Brien, T. Kevin

Fatigue Crack Closure Analysis Using Digital Image Correlation

Fatigue crack closure during crack growth testing is analyzed in order to evaluate the critieria of ASTM Standard E647 for measurement of fatigue crack growth rates. Of specific concern is remote closure, which occurs away from the crack tip and is a product of the load history during crack-driving-force-reduction fatigue crack growth testing. Crack closure behavior is characterized using relative displacements determined from a series of high-magnification digital images acquired as the crack is loaded. Changes in the relative displacements of features on opposite sides of the crack are used to generate crack closure data as a function of crack wake position. For the results presented in this paper, remote closure did not affect fatigue crack growth rate measurements when ASTM Standard E647 was strictly followed and only became a problem when testing parameters (e.g., load shed rate, initial crack driving force, etc.) greatly exceeded the guidelines of the accepted standard.

Leser, William P.

Air Data Boom System Development for the Max Launch Abort System (MLAS) Flight Experiment

In 2007, the NASA Exploration Systems Mission Directorate (ESMD) chartered the NASA Engineering Safety Center (NESC) to demonstrate an alternate launch abort concept as risk mitigation for the Orion project's baseline "tower" design. On July 8, 2009, a full scale and passively, aerodynamically stabilized MLAS launch abort demonstrator was successfully launched from Wallops Flight Facility following nearly two years of development work on the launch abort concept: from a napkin sketch to a flight demonstration of the full-scale flight test vehicle. The MLAS flight test vehicle was instrumented with a suite of aerodynamic sensors. The purpose was to obtain sufficient data to demonstrate that the vehicle demonstrated the behavior predicted by Computational Fluid Dynamics (CFD) analysis and wind tunnel testing. This paper describes development of the Air Data Boom (ADB) component of the aerodynamic sensor suite.

Woods-Vedeler, Jessica A.

Evaluation of a Small-Crack Monitoring System

A new system has been developed to obtain fatigue crack growth rate data from a series of images acquired during fatigue testing of specimens containing small surface cracks that initiate at highly-polished notches. The primary benefit associated with replica-based crack growth rate data methods is preserving a record of the crack configuration during the life of the specimen. Additionally, this system has the benefits of both reducing time and labor, and not requiring introduction of surface replica media into the crack. Fatigue crack growth rate data obtained using this new system are found to be in good agreement with similar results obtained from surface replicas.

Newman, John A.

A Relationship Between Constraint and the Critical Crack Tip Opening Angle

Of the various approaches used to model and predict fracture, the Crack Tip Opening Angle (CTOA) fracture criterion has been successfully used for a wide range of two-dimensional thin-sheet and thin plate applications. As thicker structure is considered, modeling the full three-dimensional fracture process will become essential. This paper investigates relationships between the local CTOA evaluated along a three-dimensional crack front and the corresponding local constraint. Previously reported tunneling crack front shapes were measured during fracture by pausing each test and fatigue cycling the specimens to mark the crack surface. Finite element analyses were run to model the tunneling shape during fracture, with the analysis loading conditions duplicating those tests. The results show an inverse relationship between the critical fracture value and constraint which is valid both before maximum load and after maximum load.

Johnston, William M.

Fracture Testing of Integral Stiffened Structure

Laboratory testing was conducted to evaluate safety concerns for integrally-stiffened tanks that were found to have developed cracks during pressurization testing. Cracks occurred at fastener holes where additional stiffeners were attached to the integrally-stiffened tank structure. Tests were conducted to obtain material properties and to reproduce the crack morphologies that were observed in service to help determine if the tanks are safe for operation. Reproducing the cracking modes observed during pressurization testing required a complex loading state involving both a tensile load in the integrally-stiffened structure and a pin-load at a fastener hole.

Newman, John A.

X-43A Rudder Spindle Fatigue Life Estimate and Testing

Fatigue life analyses were performed using a standard strain-life approach and a linear cumulative damage parameter to assess the effect of a single accidental overload on the fatigue life of the Haynes 230 nickel-base superalloy X-43A rudder spindle. Because of a limited amount of information available about the Haynes 230 material, a series of tests were conducted to replicate the overload and in-service conditions for the spindle and corroborate the analysis. Both the analytical and experimental results suggest that the spindle will survive the anticipated flight loads.

Glaessgen, Edward H.

Influence of Crack-Tip Configurations on the Fracture Response of 0.04-Inch Thick 2024-T3 Aluminum Alloy Sheet

A series of fracture tests were conducted on Middle-crack tension M(T) and compact tension C(T) specimens to determine the effects of specimen type, specimen width, notch tip sharpness and buckling on the fracture behavior of cracked thin sheet (0.04 inch thick) 2024-T3 aluminum alloy material. A series of M(T) specimens were tested with three notch tip configurations: (1) a fatigue pre-cracked notch, (2) a 0.010-inch-diameter wire electrical discharge machined (EDM) notch, and (3) a EDM notch sharpened with a razor blade. The test procedures are discussed and the experimental results for failure stress, load vs. crack extension and the material stress-strain response are reported.

Johnston, William M.

Fracture Test Results for 0.5, 0.7 and 0.9 Inch Thick 2324-T39 Aluminum Alloy Material

A summary of experimental data is presented for a series of fracture tests and tensile tests that were conducted on a 2324-T39 aluminum alloy material. Static tensile tests were performed to determine the stress-strain response for the material. For the fracture tests three thicknesses (B = 0.5, 0.7, and 0.9-inches) and two specimen types (middle crack tension and compact tension specimens) were used. The middle crack tension specimens were 12-inches wide, and the compact tension specimens were 2, 4, and 6-inches wide. The fracture tests were conducted in the L-T orientation (crack perpendicular to the rolling direction and load parallel to the rolling direction).

Johnston, William M.

Fracture Tests on Thin Sheet 2024-T3 Aluminum Alloy for Specimens with and Without Anti-Buckling Guides

A series of fracture test were conducted to determine the effects of specimen type specimen width and buckling on the fracture behavior of cracked thin sheet (0.063 inch thick) 2024-T3 aluminum alloy. A summary of the experimental measurements is presented for fracture tests conducted on two specimen types and various widths. Middle-crack tension M(T) and compact tension C(T) specimens were tested in the L-T and T-L orientation with duplicate tests for each condition. Four widths (W= 3, 12, 24, and 40 inch) were tested for the middle-crack tension specimens, and three widths (W=2, 4, and 6 inch) were tested for the compact tension specimens. The M(T) specimens were tested in either a constrained (out-of-plane displacements restrained with antibuckling guides) or unconstrained conditions were the specimen was free to buckle out of plane Measurements were made of load against crack extension for all specimens.

Johnston, William M.