Search NASASearch

Engineering topics

Jon Mackey

Publications and source records attributed to Jon Mackey.

Wear Test of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first wear test of the 12.5 kW Advanced Electric Propulsion System Engineering Test Unit 2 (AEPS ETU-2) thruster produced by Aerojet Rocketdyne. The ETU-2 Wear Test accumulated approximately 730 hours of operation split between the nominal 600 V/12.5 kW condition and the 300 V/6.25 kW condition previously identified as the worst-case erosion condition.

Jason D. Frieman

Performance of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the performance test campaign of the 12.5 kW Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had three major goals: to assess design compliance with thruster requirements, provide a comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Units (TDUs) from which the AEPS ETU design was derived, and support AEPS application on the Power and Propulsion Element (PPE). Assessments of ETU-2 performance were conducted at discharge powers of 2.6 to 13.1 kW, which encompasses the original AEPS throttle conditions as well as those most relevant for AEPS application on PPE. The results from the test campaign indicate that ETU-2 performance meets or exceeds all AEPS thruster performance requirements and matches the values and trends previously measured with the HERMeS TDUs. In addition, similar to the HERMeS TDUs, ETU-2 performance showed minimal variation over approximately 1636 h of operating time due to the incorporation of magnetic shielding. Taken together, these results show that the AEPS design is successfully replicating the performance of the HERMeS TDUs to within the empirical uncertainty and meeting its performance requirements as the design progresses to its Critical Design Review.

HERMeS

Performance of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the performance test campaign of the 12.5 kW Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had three major goals: to assess design compliance with thruster requirements, provide a comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Units (TDUs) from which the AEPS ETU design was derived, and support AEPS application on the Power and Propulsion Element (PPE). Assessments of ETU-2 performance were conducted at discharge powers of 2.6 to 13.1 kW, which encompasses the original AEPS throttle conditions as well as those most relevant for AEPS application on PPE. The results from the test campaign indicate that ETU-2 performance meets or exceeds all AEPS thruster performance requirements and matches the values and trends previously measured with the HERMeS TDUs. In addition, similar to the HERMeS TDUs, ETU-2 performance showed minimal variation over approximately 1636 h of operating time due to the incorporation of magnetic shielding. Taken together, these results show that the AEPS design is successfully replicating the performance of the HERMeS TDUs to within the empirical uncertainty and meeting its performance requirements as the design progresses to its Critical Design Review.

Jason D Frieman

Extended Performance Characterization of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first detailed performance assessment of the Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne at the throttle conditions most relevant for AEPS application on the Gateway Power and Propulsion Element (PPE). First, an assessment was performed of ETU-2 performance and backpressure sensitivity at the previously-tested throttle points of 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW that confirmed ETU-2 and the test facility were both operating nominally and consistent with historical baselines. ETU-2 performance and stability were then assessed throughout the PPE throttle range of 2.6-12 kW and shown to be in-family with predictions based on the scaling of previous results. Taken together, these results will help inform application of AEPS on PPE as the AEPS design progresses towards its Critical Design Review.

Jason D Frieman

Risk-Based Methodology for the Determination of Hall Thruster Performance Specifications

This work adapts manufacturing and metrology industry standards to create a risk-based approach for the determination of electric propulsion performance specifications. The developed process is applied to 208 total thrust measurements acquired using three different NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Unit (TDU) 12.5-kW Hall thrusters in three different test facilities in order to generate thrust specifications at the 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW operating conditions. These thrust specifications are used to perform a set of sample acceptance tests to illustrate the importance of adding additional conservatism using a parameter known of the Test Accuracy Ratio in order to control the risk to the thruster producer and consumer from false rejection and acceptance of thruster units.

HERMeS

Extended Performance Characterization of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first detailed performance assessment of the Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne at the throttle conditions most relevant for AEPS application on the Gateway Power and Propulsion Element (PPE). First, an assessment was performed of ETU-2 performance and backpressure sensitivity at the previously-tested throttle points of 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW that confirmed ETU-2 and the test facility were both operating nominally and consistent with historical baselines. ETU-2 performance and stability were then assessed throughout the PPE throttle range of 2.6-12 kW and shown to be in-family with predictions based on the scaling of previous results. Taken together, these results will help inform application of AEPS on PPE as the AEPS design progresses towards its Critical Design Review.

HERMeS

Risk-based Methodology for the Determination of Hall Thruster Performance Specifications

This work adapts manufacturing and metrology industry standards to create a risk-based approach for the determination of electric propulsion performance specifications. The developed process is applied to 208 total thrust measurements acquired using three different NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Unit (TDU) 12.5-kW Hall thrusters in three different test facilities in order to generate thrust specifications at the 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW operating conditions. These thrust specifications are used to perform a set of sample acceptance tests to illustrate the importance of adding additional conservatism using a parameter known of the Test Accuracy Ratio in order to control the risk to the thruster producer and consumer from false rejection and acceptance of thruster units.

HERMeS

Expanded Performance Characterization of the NASA HERMeS Hall Thruster

This work presents a summary of a detailed performance assessment of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) thruster at the throttle conditions most relevant for the Gateway Power and Propulsion Element (PPE). First, an assessment was performed of TDU-3 performance and stability at the previously-tested throttle points of 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW that confirmed TDU-3 was operating nominally and consistent with historical baselines. TDU-3 performance and stability were then assessed throughout the PPE throttle range of 2.6-12 kW and shown to mirror the characteristics observed at the previously tested conditions. Finally, a statistical estimate for the thrust specification at the expanded set of throttle conditions was computed and found to yield similar tolerance ranges to those calculated for the heritage conditions. Taken together, these results provide strong evidence that the demonstrated performance characteristics of the HERMeS design are preserved at the expanded set of throttle conditions relevant to application on PPE.

HERMeS

Extended Performance Characterization of the NASA HERMeS Hall Thruster

This work presents a summary of a detailed performance assessment of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) thruster at the throttle conditions most relevant for the Gateway Power and Propulsion Element (PPE). First, an assessment was performed of TDU-3 performance and stability at the previously-tested throttle points of 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW that confirmed TDU-3 was operating nominally and consistent with historical baselines. TDU-3 performance and stability were then assessed throughout the PPE throttle range of 2.6-12 kW and shown to mirror the characteristics observed at the previously tested conditions. Finally, a statistical estimate for the thrust specification at the expanded set of throttle conditions was computed and found to yield similar tolerance ranges to those calculated for the heritage conditions. Taken together, these results provide strong evidence that the demonstrated performance characteristics of the HERMeS design are preserved at the expanded set of throttle conditions relevant to application on PPE.

HERMeS

Extended Wear Testing of the 12-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the first wear test of the 12 kW Advanced Electric Propulsion System (AEPS) intended to isolate the impact of discharge current on component wear rates. Testing was led by Aerojet Rocketdyne and performed with the AEPS Engineering Test Unit 2 (ETU-2) thruster. In total, approximately 860 hours of operation were accumulated split between operating conditions of 600 V/9 kW, 600 V/11 kW, and 600 V/12 kW. Thruster performance and stability were invariant throughout the wear test for all thruster throttle conditions and shown to be equal to the values previously measured with ETU-2. Inner front pole cover erosion rates were found to be invariant to discharge current as the measurements at all three operating conditions were equal to within the empirical uncertainty. Outer front pole cover erosion rates were found to be equal for the 600 V/9 kW and 600 V/12 kW conditions with operation at 600 V/11 kW yielding elevated erosion rates. Overall, the data shows that the AEPS thruster design has a high probability of meeting lifetime and performance requirements as the design proceeds to flight production and qualification.

Jason D Frieman

PPE Electric Propulsion Advancing to CDR: 12kW String

String level testing is a vital part of electric propulsion development. With the Power and Propulsion Element (PPE) spacecraft flying two new models of Hall Thrusters, this work is even more critical. PPE will have both 6kW and 12kW thruster strings onboard, all powered by Maxar power processing units (PPU). Both strings have recently undergone end-to-end string level hot fire testing to verify the ability of all components to work together. This entails operating the thruster with the Xenon Flow Controller (XFC) and PPUs under both nominal and off-nominal conditions to stress the system and determine weak points. Such testing has long been a standard Maxar practice since our first 1.5kW electric propulsion system in 2004. This paper will focus on Phase 1 of the 12kW testing recently completed at NASA Glenn. The primary conclusion of the test effort was that the 12kW string operated nominally and that the PPU and XFC could operate the thruster within specifications.

Electric propulsion

Edge Wear of the Advanced Electric Propulsion System Pole Covers

This work summarizes a wear test focused on characterizing the erosion of the edges and side walls of the 12-kW Advanced Electric Propulsion System (AEPS) pole covers as well as the impact of magnetic field strength on component erosion for operation at a discharge voltage of 600 V. Testing was performed with the AEPS Engineering Test Unit 2 (ETU-2) thruster and accumulated approximately 325 hours of operation at the 600 V/12 kW condition with the magnetic field strength set to 75% of its nominal value. Thruster performance was invariant throughout the wear test for all thruster throttle conditions and matched previous measurements at the nominal magnetic field strength. Contrary to past results, inner front pole cover erosion rates were invariant to magnetic field strength at the 600 V/12 kW condition and no erosion was measured on the outer front pole cover. The erosion profile of the downstream inner front pole cover faces was continuous across the cover, indicating no significant change in erosion processes at the pole cover edges. Side wall erosion was only detected on the cathode-facing surfaces of the inner front pole cover and was equal in magnitude to the rates measured on the adjacent downstream edges. Taken together, these results suggest that erosion of the pole cover edges and sidewalls is driven by cathode-borne ions and will ultimately not impact AEPS life estimates.

Hall thrusters

Edge Wear of the Advanced Electric Propulsion System Pole Covers

This work presents a summary of the first wear test of the 12 kW Advanced Electric Propulsion System (AEPS) focused on characterizing the erosion of the edges and side walls of the thruster pole covers. Testing was performed with the AEPS Engineering Test Unit 2 (ETU-2) thruster and accumulated approximately 325 hours of operation at the 600 V/12 kW condition with the magnetic field strength set to 75% of its nominal value. Thruster performance was invariant throughout the wear test for all thruster throttle conditions and was found to be equal to previous measurements. Contrary to past results, inner front pole cover erosion rates were invariant to magnetic field strength at the 600 V/12 kW condition and no erosion was measured on the outer front pole cover. The erosion profile of the downstream inner front pole cover faces was continuous across the cover indicating no significant change in erosion process at the pole cover edges. Side wall erosion was only detected on the cathode-facing surfaces of the inner front pole cover and was equal in magnitude to the rates measured on the adjacent downstream edges. Taken together, these results suggest that erosion of the pole cover edges and sidewalls is driven by cathode-borne ions and will ultimately not impact AEPS life estimates.

Hall thrusters