Search NASA⌕ Search

Engineering topics

Jonas, Michelle

Publications and source records attributed to Jonas, Michelle.

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Bo\"{o}tes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗