Search NASA⌕ Search

Engineering topics

Jonathan Stephens

Publications and source records attributed to Jonathan Stephens.

Test data analysis of the thermodynamic vent system-augmented top spray injector liquid nitrogen transfer experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

No-vent Fill↗

A Review of In-Space Propellant Transfer Capabilities and Challenges for Missions Involving Propellant Resupply

This paper captures and transfers knowledge of in-space propellant transfer accomplishments and communicate the remaining challenges to a new generation of NASA engineers as multiple NASA programs and centers have worked related and applicable efforts. The Propulsion Technical Discipline Team (TDT) established a plan to draft this paper as an effort to help engineers and decision makers recognize and access the various islands of experience that have formed within the agency as different NASA directorates and projects have embraced the challenges associated with propellant transfer.

Propellant Transfer↗

Cryogenic Fluid Management for the Artemis Program and Beyond

NASA is endeavoring on an ambitious return to the Moon and eventually on to Mars through the Artemis Program leveraging innovative technologies to establish sustainable exploration architectures collaborating with US commercial and international partners [1]. Future NASA architectures have baselined cryogenic propulsion systems to support lunar missions and ultimately future missions to Mars. NASA has been investing in maturing CFM active and passive storage, transfer, and gauging technologies over the last decade plus primarily focused on ground development with a few small-scale microgravity fluid experiments. Recently, NASA created a Cryogenic Fluid Management (CFM) Technology Roadmap identifying the critical gaps requiring further development to reach a technology readiness level (TRL) of 6 prior to infusion to flight applications. To address the technology gaps the Space Technology Mission Directorate (STMD) strategically plans to invest in a diversified CFM portfolio approach through ground and flight demonstrations, collaborating with international partners, and leveraging Public Private Partnerships (PPPs) opportunities with US industry through the Tipping Point and Announcement of Collaborative Opportunities (ACO) solicitations. Once proven, these system capabilities will enable the high performing cryogenic propellant systems needed for the Artemis Program and beyond.

Cryogenic Fluid Management↗

Testing of TVS Augmented Injectors for Tank-to-Tank Transfer of Cryogens

NASA is developing reusable cryogenic systems to enable manned missions to the Moon and Mars. These cryogenic systems will require replenishing cryogens on-orbit via a tanker or propellant depot with minimal loss to boil-off. Three additively manufactured injectors augmented with a Thermodynamic Venting System have been developed for use in tank-to-tank cryogenic fluid transfer. A Vented Chill/No-Vent Fill approach to tank-to-tank transfer has been the industry standard and is explored in this work with emphasis on injector spray patterns and compared to the Charge-Hold-Vent chill method.

Cryogenic Transfer↗

Testing of TVS Augmented Injectors for Tank-to-Tank Transfer of Cryogens

NASA is developing reusable cryogenic systems to enable manned missions to the Moon and Mars. These cryogenic systems will require replenishing cryogens on-orbit via a tanker or propellant depot with minimal loss to boil-off. Three additively manufactured injectors augmented with a Thermodynamic Venting System have been developed for use in tank-to-tank cryogenic fluid transfer. A Vented Chill/No-Vent Fill approach to tank-to-tank transfer has been the industry standard and is explored in this work with emphasis on injector spray patterns and compared to the Charge-Hold-Vent chill method.

Cryogenic Transfer↗