Search NASASearch

Engineering topics

Jones, B.

Publications and source records attributed to Jones, B..

At least 19 records

Design, Development and Testing of the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) Guidance, Navigation and Control System

Engineers at NASA Johnson Space Center have designed, developed, and tested a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spaceflight activities. The technology demonstration system, known as the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam), has been integrated into the approximate form and function of a flight system. The primary focus has been to develop a system capable of providing external views of the International Space Station. The Mini AERCam system is spherical-shaped and less than eight inches in diameter. It has a full suite of guidance, navigation, and control hardware and software, and is equipped with two digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations. Tests have been performed in both a six degree-of-freedom closed-loop orbital simulation and on an air-bearing table. The Mini AERCam system can also be used as a test platform for evaluating algorithms and relative navigation for autonomous proximity operations and docking around the Space Shuttle Orbiter or the ISS.

Wagenknecht, J.

Bolometric detectors for the high frequency instrument on the Planck surveyor

The High Frequency Instrument (HFI) on Planck will obtain all-sky images of the Cosmic Microwave Background (CMB) and other astrophysical sources of emission with resolution of 9 arcniin at 100 GHz, 7 arcmin at 143 GHz and 5 arcniin at 217, 353, 545 and 857 GHz. The HFI focal plane will contain 48 silicon nitride micromesh bolometric detectors operating from a 100 mK heat sink. Four detectors in each of the 6 bands will detect the sum of the power in both linear polarizations. An additional 4 pair of detectors will provide sensitivity to linear polarization of emission at 143, 217 and 353 GHz. We report on the development of these detectors, which are being produced at the JPL Micro Devices Laboratory, packaged at JPL Electronics Packaging, characterized at 100 mK before delivery to our HFI consortium partners at the UWCC, UK.

Planck CMB bolometer

Laser Micromachining Fabrication of THz Components

Laser micromachining techniques can be used to fabricate high-quality waveguide structures and quasi-optical components to micrometer accuracies. Successful GHz designs can be directly scaled to THz frequencies. We expect this promising technology to allow the construction of the first fully integrated THz heterodyne imaging arrays. At the University of Arizona, construction of the first laser micromachining system designed for THz waveguide components fabrication has been completed. Once tested and characterized our system will be used to construct prototype THz lx4 focal plane mixer arrays, magic tees, AR coated silicon lenses, local oscillator source phase gratings, filters and more. Our system can micro-machine structures down to a few microns accuracy and up to 6 inches across in a short time. This paper discusses the design and performance of our micromachining system, and illustrates the type, range and performance of components this exciting new technology will make accessible to the THz community.

DrouetdAubigny, C.

Constraints on the nucleus and dust properties from mid-infrared imaging of comet Hyakutake

We use Mie scattering theory to determine the expected thermal emission from dust grains in cometary comae and apply these results to mid-infrared images of comet Hyakutake (C/1996 B2) obtained preperihelion in 1996 March. Calculations were performed for dust grains in the size range from 0.1 to 10 micrometers for two different compositions: amorphous olivine (a silicate glass) and an organic residue mixture. The resulting emission efficiencies are complicated functions of wavelength and particle size and are significantly different for the two materials in question. The Hyakutake data set consists of three nights of high-resolution imaging (100-150 km pixel-1 at the comet) of the inner coma at 8.7, 11.7, 12.5, and 19.7 micrometers. Attempts to fit the observed colors (ratios of fluxes at different wavelengths) using a single grain composition failed. However, fits to the data were achieved for all three nights using a mixture of approximately 1 micrometer olivine grains and approximately 7 micrometers organic grains. The resulting olivine mass fraction was between 8% and 16% of the total dust mass-loss rate. We also estimate the radius of the nucleus to be r = 2.1 +/- 0.4 km.

Non-NASA Center

10 and 20 micron imaging with arrays

We discuss imaging with arrays in the thermal IR. Aspects of the design and performance of the 'Golden Gopher', an infrared array camera are presented. This instrument operates in a high-background environment, for ground-based astronomical imaging from 5 to 27 micrometers. It is built around a 20 x 64 element Si:As Impurity Band Conduction (IBC) device manufactured by GenCorp Aerojet Electronic Systems Division, and has a noise-equivalent flux density (NEFD) of 23.5 mJy (min(exp -1/2) (arcsec(exp -2) at lambda = 10 micrometers, delta-lambda = 1 micrometer, on the Mt. Lemmon 1.5m telescope. We present and discuss a sample of the data. In addition we discuss the design and expected performance of the 'Long Wavelength Spectrometer' which is now under construction for the Keck telescope.

Jones, B.

12 and 20 micron imaging of the starburst galaxy NGC 253

The study presents 12- and 20-micron imaging of the starburst galaxy NGC 253 with a spatial resolution of 0.8 arcsec. A positional uncertainty of 1.6 arcsec in these images is estimated on the basis of previous ground-based mid-IR studies to determine the absolute position of the images. It is concluded that the proposed 'nucleus' of NGC 253, i.e., the dominant, bright, flat-spectrum radio source identified by Turner & Ho (1985) (TH 2), is not associated with the mid-IR peak, but rather is located 2.2 arcsec to the northeast. The mid-IR peak, IRS 1, is placed midway between TH 6 and TH 7. Several coincidences with the present 12-micron image are found: IRS 1 falls within 1 arcsec of the 2-micron peak; a second significantly weaker IR source, IRS 2, coincides with TH 2; and the brightest steep-spectrum 6-cm radio source, TH 9, coincides with a 'tongue' of emission extending to the southwest of IRS 1.

Pina, R. K.

Imaging and spectroscopic studies of the interacting system Markarian 171

V, R, and I broadband CCD images, as well as H-alpha spectroscopic observations of Markarian 171, are presented. Two apparently interacting dust-enshrouded galaxies exhibit relatively normal V-R, V-I galactic stellar-population colors in their outer regions, and spatially extended H-alpha emission. However, the dereddened colors imply a hot stellar population. The dual characteristics of narrow H-alpha lines and spatially extended H-alpha emission clearly distinguish this type of activity from that associated with the compact central regions of active galactic nuclei and QSOs. Apparently, in the case of Mk 171 the interaction has induced star formation throughout a significant fraction of the galaxy (kiloparsecs) - not just in the immediate vicinity of the nucleus (parsecs). A peculiar stellar population of hot stars associated with a knot of weak H-alpha emission appears spatially separate from the other emission-line regions. It is possible that this stellar knot is a severed remnant attributable to the gravitational interaction between the two galaxies.

Friedman, Scott D.

Development of optimized detector/spectrophotometer technology for low background space astronomy missions

This program was directed towards a better understanding of some of the important factors in the performance of infrared detector arrays at low background conditions appropriate for space astronomy. The arrays were manufactured by Aerojet Electrosystems Corporation, Azusa. Two arrays, both bismuth doped silicon, were investigated: an AMCID 32x32 Engineering mosiac Si:Bi accumulation mode charge injection device detector array and a metal oxide semiconductor/field effect transistor (MOS-FET) switched array of 16x32 pixels.

Jones, B.

Abundances in galactic H II regions. III - G25.4-0.2, G45.5+0.06, M8, S159, and DR 22

Measurements of the ARII (6.99 microns), ArIII (8.99 microns), NeI (12.81 microns), SIII (18.71 microns), and SIV (10.51 microns) lines are presented for five compact HII regions along with continuum spectroscopy. From these data and radio data, lower limits to the elemental abundances of Ar, S, and Ne were deduced. The complex G25.4-0.2 is only 5.5 kpc from the galactic center, and is considerably overabundant in all these elements. Complex G45.5+0.06 is at seven kpc from the galactic center, and appears to be approximately consistent with solar abundance. The complex S159 in the Perseus Arm, at 12 kpc from the galactic center, has solar abundance, while M8 in the solar neighborhood may be somewhat overabundant in Ar and Ne. Complex DR 22, at 10 kpc from the galactic center in the Cygnus Arm, is overabundant in Ar. A summary of results from a series of papers on abundances is given.

Pipher, J. L.

Abundances in galactic H2 regions, 3: G25.4-0.2, G45.5+0.06, M8, S159 and DR22

Measurements of the ARII (6.99 microns), ArIII (8.99 microns), NeII (12.81 microns), SIII (18.71 microns), and SIV (10.51 microns) lines are presented for five compact HII regions along with continuum spectroscopy. From these data and radio data, lower limits to the elemental abundances of Ar, S, and Ne were deduced. The complex G25.4-0.2 is only 5.5 kpc from the galactic center, and is considerably overabundant in all these elements. Complex G45.5+0.06 is at seven kpc from the galactic center, and appears to be approximately consistent with solar abundance. The complex S159 in the Perseus Arm, at 12 kpc from the galactic center, has solar abundance, while M8 in the solar neighborhood may be somewhat overabundant in Ar and Ne. Complex DR 22, at 10 kpc from the galactic center in the Cygnus Arm, is overabundant in Ar. A summary of results from a series of papers on abundances is given.

Pipher, J. L.

Infrared astronomy research and high altitude observations

Highlights are presented of studies of the emission mechanisms in the 4 to 8 micron region of the spectrum using a circular variable filter wheel spectrometer with a PbSnTe photovoltaic detector. Investigations covered include the spectroscopy of planets, stellar atmospheres, highly obscured objects in molecular clouds, planetary nebulae, H2 regions, and extragalactic objects.

Jones, B.

A low noise infrared spot scanner for testing detector arrays

A low noise spot scanner has been built for use in testing the performance of infrared detector arrays for NASA's IR detector technology development program and the University of California's MICRO program. The scanner provides a convenient low noise detector test environment and a wide range of test conditions including versatile temperature control of the detector, ambient background, and blackbody source temperature and control of spot size, color, and brightness.

Puetter, R. C.

UCSD IR detector development programs

A diagram is presented for the UCSD low background infrared spot scanner. The spot scanner parameters are outlined. The testing that is planned for the charge injection device is outlined. The Aerojet linear 128 element array is also outlined.

Jones, B.

Two multifrequency observations of the BL Lacertae object OJ 287

Results are reported for various sets of X-ray, UV, visual, IR, millimeter, and radio observations of OJ 287. The spectral information is used to constrain nonthermal energy production models for the source, and three possible models are considered. It is found that, in order to describe all the observed flux in the radio to X-ray bands with a synchrotron self-Compton model, a high degree of relativistic beaming is required such that the equivalent Doppler factor ranges from about 20 to 165. It is concluded that submillimeter flux and X-ray spectral measurements could distinguish between the two possible models that fit the present observations.

Worrall, D. M.

Near-infrared spectrophotometry of four Seyfert 1 galaxies and NGC 1275

Low-resolution spectrophotometry from 2 to 4 microns is reported for the four Seyfert 1 galaxies Mrk 335, 3C 120, Mrk 509, NGC 7469, and the peculiar emission-line galaxy NGC 1275. The spectrum of NGC 7469 exhibits a strong 3.3-micron dust feature, indicating a thermal origin for the bulk of its considerable nonstellar infrared emission. NGC 1275 has a large stellar contribution to its infrared flux at wavelengths shortward of 3 microns. The spectrum from 3 to 4 microns fits a power law which fits the 10-micron and 20-micron broad bands, as well. A thermal model which can explain the spectrum of NGC 1275 is discussed. Mrk 335 displays a complex spectrum suggestive of thermal dust emission. 3C 120 and Mrk 509 have nonstellar infrared emission shortward of 2 microns, but the data are ambiguous as to whether this emission is thermal or nonthermal in origin.

Rudy, R. J.