Search NASA⌕ Search

Engineering topics

Jones, Edward A.

Publications and source records attributed to Jones, Edward A..

Factors and Considerations for Modeling Loss of a GaN-based Inverter

The article investigates the impacts of four often-neglected factors on the loss model of a GaN-based full-bridge inverter: parasitic capacitance of the devices, dynamics of junction temperature (Tj) under time-varying power dissipation (Ploss), case temperature estimation, and detailed considerations of the passive components. Procedures to calculate the converter loss considering the above factors are proposed and implemented. A 4.5-kW hard-switching inverter prototype using gallium nitrite (GaN) high-electron-mobility transistors is used to experimentally demonstrate the impact of each factor on the converter loss model. Furthermore, it is found that the accuracy of a converter loss model is mainly affected by the passive components at the light load condition, whereas the thermal and loss models of the active components become the major factors as the output power increases. The results show that after considering the above factors, the converter loss discrepancy between calculation and measurement can be reduced from 30.6 W (28%) to 2.5 W (less than 3%) at heavy load (Po = 4.5 kW), while at the light load condition (Po = 500 W), it is reduced from 3.9 W (28%) to 2.6 W (16%). Furthermore, the difference between simulated and measured case temperature of the GaN devices is within 6 °C.

42 ENGINEERING↗

Methodology for Wide Band-Gap Device Dynamic Characterization

Here, the double pulse test (DPT) is a widely accepted method to evaluate the dynamic behavior of power devices. Considering the high switching-speed capability of wide band-gap devices, the test results are very sensitive to the alignment of voltage and current (V-I) measurements. Also, because of the shoot-through current induced by Cdv/dt (i.e., cross-talk), the switching losses of the nonoperating switch device in a phase-leg must be considered in addition to the operating device. This paper summarizes the key issues of the DPT, including components and layout design, measurement considerations, grounding effects, and data processing. Additionally, a practical method is proposed for phase-leg switching loss evaluation by calculating the difference between the input energy supplied by a dc capacitor and the output energy stored in a load inductor. Based on a phase-leg power module built with 1200-V/50-A SiC MOSFETs, the test results show that this method can accurately evaluate the switching loss of both the upper and lower switches by detecting only one switching current and voltage, and it is immune to V-I timing misalignment errors.

30 DIRECT ENERGY CONVERSION↗

Circulating Current Suppressing Control’s Impact on Arm Inductance Selection for Modular Multilevel Converter

Arm inductor in a modular multilevel converter (MMC) is used to limit the circulating current and dc short circuit fault current. The circulating current in MMC is dominated by second-order harmonic, which can be largely reduced with circulating current suppressing control. By analyzing the mechanism of the circulating current suppressing control, it is found that the circulating current at switching frequency becomes the main harmonic when suppression control is implemented. Unlike the second-order harmonic that circulates only within the three phases, switching frequency harmonic also flows through the dc side and may further cause high-frequency dc voltage harmonic. This article develops the theoretical relationship between the arm inductance and switching frequency circulating current, which can be used to guide the arm inductance selection. The experimental results with a downscaled MMC prototype verify the existence of the switching frequency circulating current and its relationship with arm inductance.

30 DIRECT ENERGY CONVERSION↗