Engineering topics
Jones, Michael
Publications and source records attributed to Jones, Michael.
EXPERIMENTAL VALIDATION OF THE FIRST 1-MA WATER-INSULATED MYKONOS LTD VOLTAGE ADDER.
Abstract not provided.
Experimental Measurements of the Convolute Plasma on the Z-Machine.
Abstract not provided.
Plasma Formation and the Correlation with Current Loss in Post-Hole Convolutes.
Abstract not provided.
Spectroscopic Measurements in the Post-Hole Convolute on Sandia's Z-Machine.
Abstract not provided.
ANALYSIS OF IMPLOSION AND STAGNATION OF STAINLESS STEEL WIRE ARRAY Z-PINCHES AT 18MA ON THE Z GENERATOR.
Abstract not provided.
Spectroscopic Measurements in the Post-Hole Convolute on Sandia's Z-Machine.
Abstract not provided.
Experimental Validation of the First 1-MA Water Insulated Mykonos LTD Voltage Adder.
Abstract not provided.
The SEMATECH Berkeley MET: extending EUV learning to 16-nm half pitch
Several high-performing resists identified in the past two years have been exposed at the 0.3-numerical-aperture (NA) SEMATECH Berkeley Microfield Exposure Tool (BMET) with an engineered dipole illumination optimized for 18-nm half pitch. Five chemically amplified platforms were found to support 20-nm dense patterning at a film thickness of approximately 45 nm. At 19-nm half pitch, however, scattered bridging kept all of these resists from cleanly resolving larger areas of dense features. At 18-nm half pitch, none of the resists were are able to cleanly resolve a single line within a bulk pattern. With this same illumination a directly imageable metal oxide hardmask showed excellent performance from 22-nm half pitch to 17-nm half pitch, and good performance at 16-nm half pitch, closely following the predicted aerial image contrast. This indicates that observed limitations of the chemically amplified resists are indeed coming from the resist and not from a shortcoming of the exposure tool. The imageable hardmask was also exposed using a Pseudo Phase-Shift-Mask technique and achieved clean printing of 15-nm half pitch lines and modulation all the way down to the theoretical 12.5-nm resolution limit of the 0.3-NA SEMATECH BMET.
Extreme-UV Self-Emission from Plasma-Focus Radial Wire Array.
Abstract not provided.
Displacement current phenomena in the magnetically insulated transmission lines of the refurbished Z accelerator.
Abstract not provided.
Development of an 85KJ Stainless Steel K-Shell X-ray Source on the Z Generator.
Abstract not provided.
Validated 3-D MHD Simulations of Optimized Singe and Nested Wire Array Z-Pinches with Detailed Circuit Coupling.
Abstract not provided.
Large Diameter Copper Wire Array Implosions for K-Shell X-Ray Generation on the Refurbished Z Machine.
Abstract not provided.
A Comparison Study of Normal-Incidence Acoustic Impedance Measurements of a Perforate Liner
The eduction of the acoustic impedance for liner configurations is fundamental to the reduction of noise from modern jet engines. Ultimately, this property must be measured accurately for use in analytical and numerical propagation models of aircraft engine noise. Thus any standardized measurement techniques must be validated by providing reliable and consistent results for different facilities and sample sizes. This paper compares normal-incidence acoustic impedance measurements using the two-microphone method of ten nominally identical individual liner samples from two facilities, namely 50.8 mm and 25.4 mm square waveguides at NASA Langley Research Center and the University of Florida, respectively. The liner chosen for this investigation is a simple single-degree-of-freedom perforate liner with resonance and anti-resonance frequencies near 1.1 kHz and 2.2 kHz, respectively. The results show that the ten measurements have the most variation around the anti-resonance frequency, where statistically significant differences exist between the averaged results from the two facilities. However, the sample-to-sample variation is comparable in magnitude to the predicted cross-sectional area-dependent cavity dissipation differences between facilities, providing evidence that the size of the present samples does not significantly influence the results away from anti-resonance.
Current Losses in Wire Array Z-Pinches on the Z Generator.
Abstract not provided.
Status of Planar Wire Array Work at UNR Zebra and SNL Saturn.
Abstract not provided.