Search NASA⌕ Search

Engineering topics

Jones, Willis B.

Publications and source records attributed to Jones, Willis B..

Isotopic Signatures of Lithium Carbonate and Lithium Hydroxide Monohydrate Measured Using Raman Spectroscopy

Lithium isotopic ratios have wide ranging applications as chemical signatures, including improved understanding of geochemical processes and battery development. Measurement of isotope ratios using optical spectroscopies would provide an alternative to traditional mass spectrometric methods, which are expensive and often limited to a chemical laboratory. In this work, Raman spectra of 7 Li 2 CO 3 , 6 Li 2 CO 3 , 7 LiOH*H 2 O and 6 LiOH*H 2 O have been measured to determine the effect of lithium isotope substitution on the Raman molecular vibrations. Thirteen peaks were observed in the spectrum of lithium carbonate, with discernable isotopic shifts occurring in eleven of the thirteen vibrations, two of which have not been previously reported in the literature. The spectrum of lithium hydroxide monohydrate contained nine peaks, with discernable isotopic shifts occurring in eight of the nine vibrations, four of which have not been previously reported in the literature. The Raman spectral data reported here for lithium carbonate and lithium hydroxide monohydrate are in agreement with the previously reported works in the literature, in which the Raman active modes of these molecules were first identified and assigned. However, due to the stability and resolution of the detection system used in this work, isotopic shifts with a magnitude less than one wavenumber have been identified. Principal Component Regression was used to evaluate the sensitivity to isotopic content of small Raman peak shifts in Li 2 CO 3 and indicates differences greater than 2 atom-% could be reliably determined. These measurements add to the body of work on lithium isotope Raman spectroscopy for these two compounds and increases the number of Raman bands which could be used for lithium isotope content analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Closo ‐Borate Gel Polymer Electrolyte with Remarkable Electrochemical Stability and a Wide Operating Temperature Window

Abstract A major challenge in the pursuit of higher‐energy‐density lithium batteries for carbon‐neutral‐mobility is electrolyte compatibility with a lithium metal electrode. This study demonstrates the robust and stable nature of a closo ‐borate based gel polymer electrolyte (GPE), which enables outstanding electrochemical stability and capacity retention upon extensive cycling. The GPE developed herein has an ionic conductivity of 7.3 × 10 −4 S cm −2 at room temperature and stability over a wide temperature range from −35 to 80 °C with a high lithium transference number ( = 0.51). Multinuclear nuclear magnetic resonance and Fourier transform infrared are used to understand the solvation environment and interaction between the GPE components. Density functional theory calculations are leveraged to gain additional insight into the coordination environment and support spectroscopic interpretations. The GPE is also established to be a suitable electrolyte for extended cycling with four different active electrode materials when paired with a lithium metal electrode. The GPE can also be incorporated into a flexible battery that is capable of being cut and still functional. The incorporation of a closo ‐borate into a gel polymer matrix represents a new direction for enhancing the electrochemical and physical properties of this class of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Li Isotope Signatures using Optical Spectroscopies

The primary goal of this work is to investigate the detection capabilities of laser ablation molecular isotopic spectrometry (LAMIS) and Raman spectroscopy for lithium isotopic determination as related to Li enrichment activities. LAMIS is an emerging spectroscopic technique that takes advantage of the fact that molecules exhibit much larger isotopic wavelength shifts in molecular emission spectra than their atomic counterparts. Raman spectroscopy has been shown to exhibit isotopic shifts if a given molecular vibration involves the isotope of interest. Both techniques are comprised of the same basic hardware: a spectrometer, a laser system (pulsed for LAMIS, pulsed or CW for Raman), and an intensified charge-coupled device (ICCD). Shifts in Raman spectra due to lithium isotopes in Li 2 C0 3 and LiOH*H 2 0 were observed. LAMIS measurements of the same compounds have not been successful yet, as no lithium containing molecular emissions have been identified to this point. However, an isotopic shift of the self-reversal of an atomic lithium emission was observed, which is another optical technique used to measure isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Hyperspectral Raman Imaging using a Spatial Heterodyne Spectrometer (SHS)

Savannah River National Laboratory, and the larger community, has limited chemical-specific imaging capabilities, which would be beneficial for remote detection of threat chemicals or use in inaccessible and harsh environments, as well as in-line process monitoring. The project objective is to develop a novel, rugged, highly sensitive spectrometer to support real-time, chemically specific imaging using hyperspectral Raman spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗