Search NASA⌕ Search

Engineering topics

Jordan, A.

Publications and source records attributed to Jordan, A..

An international benchmark for wind plant wakes from the American WAKE ExperimeNt (AWAKEN)

This article introduces the first benchmark study within the International Energy Agency Wind Task 57 framework, focusing on wind plant wakes. Leveraging data from the American WAKE ExperimeNt (AWAKEN), the benchmark aims to assess the accuracy of simulation tools in modeling wind plant wakes and their impact on the downstream flow under diverse inflow conditions. The AWAKEN field campaign, conducted in Oklahoma from 2022 to 2024, provides unprecedented observations of wind plant-atmosphere interactions, thus offering a large dataset to validate numerical models of different complexity. The benchmark will include three phases—code calibration, blind comparison, and iteration—allowing participants to refine their numerical models based on the feedback from the benchmark team. This article describes the benchmark case study selected from observations providing details on atmospheric conditions, wake evidence, and wind turbine operation. The benchmark’s structure and timeline, along with the expected publication of results, are discussed as well. This collaborative effort aims to enhance the accuracy of wind plant wake simulations, thus contributing to the improvement of wind energy production estimates.

17 WIND ENERGY↗

The Influence of Aqueous Dispersivity on Transport of Radiological Material at LANL MDA G - 20450

Aqueous dispersivity is a phenomenon by which a solute moving in groundwater mixes with water that does not contain the solute and becomes diluted. Solutes take paths of varying lengths through pore networks or experience slower velocities due to interactions with pore walls. Aqueous dispersivity leads to breakthrough curves with earlier arrival than expected in purely advective systems and persistent 'tails,' or late-arriving, dilute concentrations of the solute. Dispersivity can be longitudinal (in the direction of flow) or transverse (orthogonal to flow). LANL has disposed of radioactive material at Material Disposal Area (MDA) G since the late 1950's. Most of the disposed materials at MDA G are low-level waste (LLW), but other types of radioactive wastes are disposed or stored at the site. For example, there is a collection of remote-handled transuranic waste (RH-TRU) waste in 33 shafts, which were intended to be stored retrievably. Aqueous-phase radionuclides included in models of contaminant transport at MDA G are subject to dispersive processes in porous media of the vadose zone and saturated zone. To model dispersivity at MDA G probabilistically, we created site-specific distributions of aqueous dispersivity. First, we performed a comprehensive review of peer-reviewed publications, reports from other performance assessments of MDA G, and documentation from sites that were considered similar based on expert opinion, such as Yucca Mountain. Data were included from a wide range of sources, so that distributions developed based on the data reflect the current state of knowledge in properties of the subsurface environment. Data were grouped based on value type (e.g., determined via experiment or used in a different model), rock type, zone type (saturated or unsaturated), and site, and were weighted in the distributions according to their relevance to the site and zone type. We combined Monte Carlo simulation and bootstrapping techniques to produce approximate distributions of mean aqueous dispersivity. Distributions of dispersivity for saturated and unsaturated zone transport are differentiated by data weight and the length scales over which transport occurs. We find that underestimating or disregarding transverse dispersivity may lead to overstating simulated well capture in the saturated zone at MDA G. Neglecting transverse dispersivity is a common assumption due in part to use of one-dimensional transport models that do not consider solute spreading orthogonal to flow. Also, we find that variability in longitudinal dispersivity is associated with substantial travel time alterations in the MDA G unsaturated zone and in simulated contaminant breakthrough times at a downstream observation plane in the MDA G saturated zone. Finally, at large scales (>1000 m), a linear trend between the dispersivity coefficient and length over which transport occurs may overestimate the dispersivity coefficient. Future modeling work with application to solute spreading could include interacting advective and diffusive zones in the highly fractured basalt below MDA G. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Umkehr Ozone Profile Retrievals

NOAA Dobson Umkehr ozone profile records have been collected since the 1970s. Umkehr ozone profiles are used to monitor stratospheric ozone recovery predicted to occur by the 2050s. Current operational Dobson Umkehr profile algorithms produce data that have uncertainty on the order of ~ 5 % in the stratosphere. However, when large volcanic eruptions inject aerosols into the stratosphere, the errors can be as large as 70 %. In order to evaluate Umkehr records for aerosol-related and instrumental artifacts, we compare observations with a Hindcast simulation of the NASA Merra-2 Global Modeling Initiative (GMI) Replay (M2GMI, Orbe et al, 2017; Wargan et al, 2018) and Chemistry Transport Model (GMI CTM, Strahan et al, 2013, Strahan et al, 2016). The biases found between the models and observations are summarized for each Dobson calibration and volcanic eruption period, thus providing a reference tool for homogenization of the Umkehr time series and removal of volcanic aerosol errors.

Petropavlovskikh, I.↗

Correction Technique for Raman Water Vapor Lidar Signal-Dependent Bias and Suitability for Water Wapor Trend Monitoring in the Upper Troposphere

The MOHAVE-2009 campaign brought together diverse instrumentation for measuring atmospheric water vapor. We report on the participation of the ALVICE (Atmospheric Laboratory for Validation, Interagency Collaboration and Education) mobile laboratory in the MOHAVE-2009 campaign. In appendices we also report on the performance of the corrected Vaisala RS92 radiosonde measurements during the campaign, on a new radiosonde based calibration algorithm that reduces the influence of atmospheric variability on the derived calibration constant, and on other results of the ALVICE deployment. The MOHAVE-2009 campaign permitted the Raman lidar systems participating to discover and address measurement biases in the upper troposphere and lower stratosphere. The ALVICE lidar system was found to possess a wet bias which was attributed to fluorescence of insect material that was deposited on the telescope early in the mission. Other sources of wet biases are discussed and data from other Raman lidar systems are investigated, revealing that wet biases in upper tropospheric (UT) and lower stratospheric (LS) water vapor measurements appear to be quite common in Raman lidar systems. Lower stratospheric climatology of water vapor is investigated both as a means to check for the existence of these wet biases in Raman lidar data and as a source of correction for the bias. A correction technique is derived and applied to the ALVICE lidar water vapor profiles. Good agreement is found between corrected ALVICE lidar measurments and those of RS92, frost point hygrometer and total column water. The correction is offered as a general method to both quality control Raman water vapor lidar data and to correct those data that have signal-dependent bias. The influence of the correction is shown to be small at regions in the upper troposphere where recent work indicates detection of trends in atmospheric water vapor may be most robust. The correction shown here holds promise for permitting useful upper tropospheric water vapor profiles to be consistently measured by Raman lidar within NDACC (Network for the Detection of Atmospheric Composition Change) and elsewhere, despite the prevalence of instrumental and atmospheric effects that can contaminate the very low signal to noise measurements in the UT.

MOHAVE-2009↗

Validation of MIPAS IMK-IAA Temperature, Water Vapor, and Ozone Profiles with MOHAVE-2009 Campaign Measurements

MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofısica de Andalucıa (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infrared (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.

MIPAS validation↗