SU-G-IeP2-09: Iodine Imaging at Spectral CT with a Dual-Layer Detector

Purpose: To evaluate the attenuation response of iodine and the accuracy of iodine quantification on a detector-based spectral CT scanner. Methods: A Gammex 461A phantom was scanned using a dual-layer detector (IQon, Philips) at 120 kVp using helical acquisition with a CDTIvol of 15 mGy to approximate the hospital’s clinical body protocol. No modifications to the standard protocol were necessary to enable spectral imaging. Iodine inserts at 6 concentrations (2, 5, 7.5, 10, 15, 20 mg/ml) were scanned individually at the center of the phantom and the 20 mg/ml insert was additionally scanned at the 3, 6, and 12 o’clock positions. Scans were repeated 10 times. Conventional, virtual monoenergetic (40–200 keV) and iodine-no-water images (with pixel values equal to iodine concentration of corresponding tissue) were reconstructed from acquired data. A circular ROI (diameter=30 pixels) was used in each conventional and monoenergetic image to measure the mean and standard deviation of the CT number in HU and in each iodine-no-water image to measure iodine concentration in mg/ml. Results: Mean CT number and contrast-to-noise ratio (CNR) measured from monoenergetic images increased with decreasing keV for all iodine concentrations and matched measurements from conventional images at 75 keV. Measurements from the 20 ml insert showed the CT number is independent of location and CNR is a function only of noise, which was higher in the center. Measured concentration from iodine-no-water images matched phantom manufacturer suggested concentration to within 6% on average for inserts at the center of the phantom. Measured concentrations were systematically higher due to optimization of iodine quantification parameters for clinical mixtures of iodine and blood/tissue. Conclusion: Spectral acquisition and reconstruction with a dual-layer detector represents the physical behavior of iodine as expected and accurately quantifies the material concentration. This should permit a variety of clinical applications including lesion characterization, vessel patency, and myocardial perfusion. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-11: Objective Image Characterization of Spectral CT with a Dual-Layer Detector

Purpose: To obtain objective reference data for the spectral performance on a dual-layer detector CT platform (IQon, Philips) and compare virtual monoenergetic to conventional CT images. Methods: Scanning was performed using the hospital’s clinical adult body protocol: helical acquisition at 120kVp, with CTDIvol=15mGy. Multiple modules (591, 515, 528) of a CATPHAN 600 phantom and a 20 cm diameter cylindrical water phantom were scanned. No modifications to the standard protocol were necessary to enable spectral imaging. Both conventional and virtual monoenergetic images were generated from acquired data. Noise characteristics were assessed through Noise Power Spectra (NPS) and pixel standard deviation from water phantom images. Spatial resolution was evaluated using Modulation Transfer Functions (MTF) of a tungsten wire as well as resolution bars. Low-contrast detectability was studied using contrast-to-noise ratio (CNR) of a low contrast object. Results: MTF curves of monoenergetic and conventional images were almost identical. MTF 50%, 10%, and 5% levels for monoenergetic images agreed with conventional images within 0.05lp/cm. These observations were verified by the resolution bars, which were clearly resolved at 7lp/cm but started blurring at 8lp/cm for this protocol in both conventional and 70 keV images. NPS curves indicated that, compared to conventional images, the noise power distribution of 70 keV monoenergetic images is similar (i.e. noise texture is similar) but exhibit a low frequency peak at keVs higher and lower than 70 keV. Standard deviation measurements show monoenergetic images have lower noise except at 40 keV where it is slightly higher. CNR of monoenergetic images is mostly flat across keV values and is superior to that of conventional images. Conclusion: Values for standard image quality metrics are the same or better for monoenergetic images compared to conventional images. Results indicate virtual monoenergetic images can be used without any loss in image quality or noise penalties relative to conventional images. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

TU-C-18C-01: Medical Physics 1.0 to 2.0: Introduction and Panel Discussion

Medical Physics 2.0, a new frontier in clinical imaging physics: Diagnostic imaging has always been a technological highlight of modern medicine. Imaging systems, with their ever-expanding advancement in terms of technology and application, increasingly require skilled expertise to understand the delicacy of their operation, monitor their performance, design their effective use, and ensure their overall quality and safety, scientifically and in quantitative terms. Physicists can play a crucial role in that process. But that role has largely remained a severely untapped resource. Many imaging centers fail to appreciate this potential, with medical physics groups either nonexistent or highly understaffed and their services poorly integrated into the patient care process. As a field, we have yet to define and enact how the clinical physicist can engage as an active, effective, and integral member of the clinical team, and how the services that she/he provides can be financially accounted for. Physicists do and will always contribute to research and development. However, their indispensible contribution to clinical imaging operations is something that has not been adequately established. That, in conjunction with new realities of healthcare practice, indicates a growing need to establish an updated approach to clinical medical imaging physics. This presentation aims to describe a vision as how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement addressing topics such as new non-classical challenges of new technologies, quantitative imaging, and operational optimization. The Medical Physics 2.0 paradigm extends clinical medical physics from isolated characterization of inherent properties of the equipment to effective use of the equipment and to retrospective evaluation of clinical performance. This is an existential transition of the field that speaks to the new paradigms of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. The panel discussion that follows includes prominent practitioners, thinkers, and leaders that would lead the discussion on how Medical Physics 2.0 can be actualized. Topics of discussion will include the administrative, financial, regulatory, and accreditation requirements of the new paradigm, effective models of practice, and the steps that we need to take to make MP 2.0 a reality. Learning Objectives: To understand the new paradigm of clinical medical physics practice extending from traditional insular models of compliance towards teambased models of operational engagement. To understand how clinical physics can most effectively contribute to clinical care. Learn to identify strengths and weaknesses in studies designed to measure the effect of low doses of ionizing radiation To recognize the impediments to Medical Physics 2.0 paradigm.

60 APPLIED LIFE SCIENCES↗

Direct Analysis of JV-Curves Applied to an Outdoor-Degrading CdTe Module (Presentation)

We present the application of a phenomenological four parameter equation to fit and analyze regularly measured current density-voltage JV curves of a CdTe module during 2.5 years of outdoor operation. The parameters are physically meaningful, i.e. the short circuit current density Jsc, open circuit voltage Voc and differential resistances Rsc, and Roc. For the chosen module, the fill factor FF degradation overweighs the degradation of Jsc and Voc. Interestingly, with outdoor exposure, not only the conductance at short circuit, Gsc, increases but also the Gsc(Jsc)-dependence. This is well explained with an increase in voltage dependent charge carrier collection in CdTe.

14 SOLAR ENERGY↗

Technology and Climate Trends in PV Module Degradation (Presentation)

To sustain the commercial success of photovoltaic (PV) technology it is vital to know how power output decreases with time. Unfortunately, it can take years to accurately measure the long-term degradation of new products, but past experience on older products can provide a basis for prediction of degradation rates of new products. An extensive search resulted in more than 2000 reported degradation rates with more than 1100 reported rates that include some or all IV parameters. In this presentation we discuss how the details of the degradation data give clues about the degradation mechanisms and how they depend on technology and climate zones as well as how they affect current and voltage differently. The largest contributor to maximum power decline for crystalline Si technologies is short circuit current (or maximum current) degradation and to a lesser degree loss in fill factor. Thin-film technologies are characterized by a much higher contribution from fill factor particularly for humid climates. Crystalline Si technologies in hot & humid climates also display a higher probability to show a mixture of losses (not just short circuit current losses) compared to other climates. The distribution for the module I-V parameters (electrical mismatch) was found to change with field exposure. The distributions not only widened but also developed a tail at the lower end, skewing the distribution.

14 SOLAR ENERGY↗

Electrical Bias as an Alternate Method for Reproducible Measurement of Copper Indium Gallium Diselenide (CIGS) Photovoltaic Modules: Preprint

Light-to-dark metastable changes in thin-film photovoltaic (PV) modules can introduce uncertainty when measuring module performance on indoor flash testing equipment. This study describes a method to stabilize module performance through forward-bias current injection rather than light exposure. Measurements of five pairs of thin-film copper indium gallium diselenide (CIGS) PV modules indicate that forward-bias exposure maintained the PV modules at a stable condition (within 1%) while the unbiased modules degraded in performance by up to 12%. It was additionally found that modules exposed to forward bias exhibited stable performance within about 3% of their long-term outdoor exposed performance. This carrier-injection method provides a way to reduce uncertainty arising from fast transients in thin-film module performance between the time a module is removed from light exposure and when it is measured indoors, effectively simulating continuous light exposure by injecting minority carriers that behave much as photocarriers do. This investigation also provides insight into the initial light-induced transients of thin-film modules upon outdoor deployment.

14 SOLAR ENERGY↗

TAS measurements for reactor physics and nuclear structure

In this contribution we will present recent total absorption measurements of the beta decay of neutron-rich nuclei performed at the IGISOL facility of the Univ. of Jyvaeskyla. In the measurements the JYFL Penning Trap was used as a high resolution isobaric separator. The total absorption technique will be described and the impact of recent results in the fields of reactor physics (decay heat calculations) and nuclear structure will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

JMP Applications in Photovoltaic Reliability (Presentation)

The ability to accurately predict power delivery over the course of time is of vital importance to the growth of the photovoltaic (PV) industry. Two key cost drivers are the efficiency with which sunlight is converted into power and secondly how this relationship develops over time. The accurate knowledge of power decline over time, also known as degradation rates, is essential and important to all stakeholders--utility companies, integrators, investors, and scientist alike. Outdoor testing plays a vital part in quantifying degradation rates of different technologies in various climates. Due to seasonal changes, however, several complete cycles (typically 3-5 years) need to be completed traditionally to obtain reasonably accurate degradation rates. In a rapidly evolving industry such atime span is often unacceptable and the need exists to determine degradation rates more accurately in a shorter period of time. Advanced time series modeling such as ARIMA (Autoregressive Integrated Moving Average) modeling can be utilized to decrease the required time span and is compared with some non-linear modeling. In addition, it will be demonstrated how the JMP 9 map feature was used toreveal important technological trends by climate.

14 SOLAR ENERGY↗

Improvements on Decay Heat Summation Calculations by Means of Total Absorption Gamma-ray Spectroscopy Measurements

The decay heat of fission products plays an important role in predictions of the heat released by nuclear fuel in reactors. In this contribution we present results of the analysis of the measurement of the beta decay of some refractory isotopes that were considered possible important contributors to the decay heat in reactors. The measurements presented here were performed at the IGISOL facility of the University of Jyvaeskylae, Finland. In our measurements we have combined for the first time a Penning trap (JYFLTRAP), which was used as a high resolution isobaric separator, with a total absorption spectrometer. The results of the measurements as well as their consequences for decay heat summation calculations are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring Degradation Rates Without Irradiance Data

A method to report PV system degradation rates without using irradiance data is demonstrated. First, a set of relative degradation rates are determined by comparing daily AC final yields from a group of PV systems relative to the average final yield of all the PV systems. Then, the difference between relative and absolute degradation rates is found from a statistical analysis. This approach is verified by comparing to methods that utilize irradiance data. This approach is significant because PV systems are often deployed without irradiance sensors, so the analysis method described here may enable measurements of degradation using data that were previously thought to be unsuitable for degradation studies.

14 SOLAR ENERGY↗

Methods for Analysis of Outdoor Performance Data (Presentation)

The ability to accurately predict power delivery over the course of time is of vital importance to the growth of the photovoltaic (PV) industry. Two key cost drivers are the efficiency with which sunlight is converted to power and secondly how this relationship develops over time. The accurate knowledge of power decline over time, also known as degradation rates, is essential and important to allstakeholders--utility companies, integrators, investors, and scientists alike. Different methods to determine degradation rates and discrete versus continuous data are presented, and some general best practice methods are outlined. In addition, historical degradation rates and some preliminary analysis with respect to climate are given.

14 SOLAR ENERGY↗

Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

14 SOLAR ENERGY↗

Reactor Decay Heat in {sup 239}Pu: Solving the {gamma} Discrepancy in the 4-3000-s Cooling Period

The {beta} feeding probability of {sup 102,104,105,106,107}Tc, {sup 105}Mo, and {sup 101}Nb nuclei, which are important contributors to the decay heat in nuclear reactors, has been measured using the total absorption technique. We have coupled for the first time a total absorption spectrometer to a Penning trap in order to obtain sources of very high isobaric purity. Our results solve a significant part of a long-standing discrepancy in the {gamma} component of the decay heat for {sup 239}Pu in the 4-3000 s range.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗