Dragonfly Entry Aerosciences Measurements (DrEAM)
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Jose Santos.
Explore the source record for details and available documents.
Detailing DrEAM measurements and objectives to fly on the Dragonfly mission.
During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating and temperatures. Discrepancies between MEDLI’s recorded in-depth heating data and the predicted thermal response and recession led to a campaign to characterize and test Mars Entry, Descent, and Landing Instrument 2 (MEDLI2) flight lot thermal protection materials (TPS) at relevant temperatures and pressures for Martian entry conditions. This paper covers the development and validation of MEDLI2 flight lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material Super-Lightweight Ablator (SLA-561V). Virgin and char thermal conductivities were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties such as virgin and char density, emissivity, absorptivity, and specific heat capacitance was also characterized and compared to the “Heritage” models used during the TPS design phase of Mars 2020. Fully Implicit Ablation and Thermal response (FIAT) simulations were completed using the Heritage and MEDLI2 material response models to provide evidence of the increased accuracy of the MEDLI2 model. FIAT predicted in-depth temperatures were compared to flight lot certification ground-test arc jet test data and MEDLI2 flight thermocouple data.
On February 18th, 2021, the Mars 2020 entry vehicle delivered the Perseverance rover to the surface of Mars. The entry vehicle carried a set of instrumentation installed on the heatshield and backshell to measure aerodynamic and aerothermal performance, named the Mars Entry, Descent, and Landing Instrumentation 2. This set of instrumentation included pressure transducers, thermocouples, heatflux sensors, and a radiometer, as well as a dedicated sensor support electronics system. All MEDLI2 hardware operated as expected during cruise and entry. MEDLI2 sensors gathered accurate pressure measurements in hypersonic through supersonic regimes to reconstruct vehicle attitude and atmospheric profiles. MEDLI2 on the heatshield sensors indicated that surface temperatures, caused by turbulent heating beginning 70 seconds after entry, remained at or below 1430 °C, while heatshield bondline temperatures rose less than 45 °C. Backshell surface TPS temperatures peaked at 630 °C, which was caused primarily by radiative heating measured by several separate sensors. The MEDLI2 temperature and pressure measurements enabled further detailed characterization of the Mars 2020 entry performance, and the flight dataset will provide a wealth of information for the EDL community and future mission designers.
Overview of the Dragonfly EDL instrumentation suite known as Dragonfly Entry Aerosciences Measurements (DrEAM)
NASA Ames and Langley are partnering with DLR to propose a comprehensive instrumentation suite known as the Dragonfly Entry Aerosciences Measurements (DrEAM). DrEAM will provide key aerothermodynamic data and performance analysis for Dragonfly’s forebody and backshell Thermal Protection System (TPS), and also includes a DLR-provided Data Acquisition System (DAS). Titan's atmosphere predominantly consists of nitrogen (~ 98% by mole) with small amounts of methane (~ 2% by mole). CN is a strong radiator and is found in nonequilibrium concentrations for Titan entry, the modeling of which has proven to be a difficult task. The DrEAM instrumentation suite will significantly advance the state-of-the-art not only by documenting the environment and performance of Dragonfly’s entry system but also by making key measurements in Titan’s atmosphere for the first time, thus providing new benchmark data applicable to entry science more generally.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Following the successful Artemis I skip reentry on December 11, 2022, unexpected char liberation from the Orion heat- shield prompted formation of an Anomaly Response Team to determine root cause and establish flight rationale and corrective actions for subsequent missions. Through a comprehensive investigation including detailed hardware analysis, modeling & simulation, and ground testing, the team determined that the low permeability Avcoat experienced extreme internal gas pressure buildup during the skip entry that could not adequately outgas, leading to crack formation and char liberation. Key discoveries included significant performance differences between permeable and impermeable heatshield regions and successful replication of the anomaly through ground testing. Based on extensive ground testing and analysis, Artemis II flew a modified trajectory without the skip entry to minimize crack-inducing conditions, and successfully splashed down on April 10, 2026 with significantly reduced char loss. For Artemis III and beyond, a corrective action was implemented to produce a more permeable version of Avcoat that will substantially reduce internal pressure accumulation during entry.