Search NASA⌕ Search

Engineering topics

Joshua M. Weisberger

Publications and source records attributed to Joshua M. Weisberger.

Compact, Self-Aligned Focusing Schlieren System

A novel compact, self-aligned focusing Schlieren system is presented that eliminates the need for a separate source grid and cutoff grid. A single grid element serves to both generate a projected source grid onto a retroreflective background, and to act as the cutoff grid for the reflected light. This is made possible by manipulating the polarization of the light through the system. The use of only a single grid element eliminates the need to create a cutoff grid that is perfectly matched and scaled to the source grid, and removes the need to align the source and cutoff grids to each other. The sensitivity to density objects is adjustable with the use of a polarizing prism. Images obtained with this system show similar operation to existing focusing Schlieren systems, but with much reduced complexity and setup time. Images taken with acrylic windows placed nor-mal to the optical axis further demonstrate the system’s utility for wind tunnel measurements.

Focusing Schlieren↗

Preparations for Tomographic Background-Oriented Schlieren Measurements in the 11-by 11-Foot Transonic Wind Tunnel

Efforts from a collaboration involving NASA’s Langley, Glenn, and Ames Research Centers to construct and test a tomographic background-oriented schlieren system in preparation for testing at the Ames 11-by 11-foot Transonic Wind Tunnel are discussed. To prepare for the test and to evaluate the probability of success, a mock-up of the tunnel test section was constructed at Langley. Schematics and renderings of the tunnel were used to place eight gigabit Ethernet CMOS cameras circumferentially around approximately 180° of the mock-up. Camera modules designed in-house were used to provide on-axis lighting to get maximum intensity return from the retroreflective backgrounds. A data acquisition system was designed to control the eight cameras and light sources with an acquisition rate of 4 Hz. A novel method for creation of the speckled background was developed for the test, enabling simple application and removal of the material on the tunnel walls. A tea light candle and a heat gun with two different nozzle shape attachments were used to provide an index of refraction gradient field to assess the quality of the 2D and tomographic results from the system. The heat gun was again used as an initial test article after the camera system had been set up at the Ames tunnel, giving similar results to those seen at the mock-up, and indicating a high probability of success for the testing campaign.

Joshua M. Weisberger↗

Shock-Wave/Boundary-Layer Interaction (SWBLI) Experiments in the Presence of Transition-to-Turbulence on a Flat Plate Model in the NASA LaRC 31-Inch Mach 10 Air Tunnel

Historically, there have been a limited number of studies involving Transitional Shock-Wave/Boundary-Layer Interactions (XSWBLI) in hypersonic flows, the majority of which have been performed at Mach Numbers of 7.5 and below. Additionally, there have been even fewer such experiments which incorporate non-intrusive and optical diagnostics. NASA Langley Research Center (NASA LaRC), in collaboration with The University of Texas at San Antonio (UTSA) and The University of Tennessee Space Institute (UTSI), is currently planning and preparing for a series of experimental aerodynamic tests using the NASA LaRC 31-inch Mach 10 Air Tunnel. The experiments will primarily focus on studying the dynamics of Shock-Wave/Boundary-Layer Interactions (SWBLI) in the presence of transition (XSWBLI) and turbulence (SWTBLI) on a large, flat plate model at a freestream Mach number of 10. Besides continued interest in understanding the flow at high Mach numbers, executing such tests at Mach 10 avoids some known concerns and will aid in solving new problems. XSWBLI are a highly unsteady phenomena and the generation of XSWBLI at lower Mach numbers can prove to be a significant challenge. This concern will be somewhat mitigated in the Mach 10 flow, as boundary layers become increasingly stabilized, but some difficulty in achieving transition is still expected. Modelling SWBLI in the presence of transitional and turbulent boundary layers has also proven to be difficult, so a high-Mach number experiment which applies non-intrusive and optical diagnostics will aid in solving a unique problem as well as advancing the understanding and characterization of an aerodynamic surface at Mach 10.The NASA LaRC 31-inch Wind Tunnel incorporates a test section having a cross-section of 31-inches × 31-inches and provides optical access to the test section via three (3) ultra-violet (UV) transmitting windows on the top, side, and bottom. The Mach 10 operating conditions will consist of pressures (P0) ranging from 2.4 to 10MPa (348 to 1,450 psi) at a temperature (T0) of 1,000 K (1,800 °R). The NASA LaRC 31-inch wind tunnel will deliver 1-minute blow-down runs, of which 30-45 seconds will be consumed to reach the aforementioned test conditions. The pump down time between runs will be approximately 45-60 minutes, which will provide for 6-10 test runs per day over the course of a weeklong entry. The proposed flat plate model will be constructed of stainless steel with geometry consisting of a10-inch × 30-inch upper surface and a 2-inch thickness. The model will be designed to support multiple leading-edge inserts in order to examine blunt, round, and sharp leading edges at Mach 10. Adjustments will be made to manage boundary layer thickness as well as the strength and size of the shock interaction region for each test. Measurements and diagnostics will be performed though high-speed Schlieren, on-body high-speed pressure transducers, IR thermography, and oil flow visualization. Hypersonic vehicle applications have and will continue to emerge at the forefront of aerospace. The NASA-UTSA-UTSI team realizes the value of characterizing SWBLI, XSWBLI, and SWTBLI behaviors well beyond single-digit hypersonic Mach numbers. As hypersonic vehicle speed capabilities continue to increase, measurement and diagnostic methods for Mach numbers of 10 and beyond will provide the foundation for a firm understanding of flow field behavior which will directly influence the advancement of technologies towards the design and manufacturing of high-speed aerodynamic surfaces, controls, thermal protection systems, acoustic treatments, and structural components. The use of non-intrusive and optical diagnostic methods in such experimentation is pivotal in developing the visualization and empirical data necessary to advance the aforementioned technology areas.

Shockwave/Boundary-Layer Interactions↗

Analysis of the Amplitude Response of a Two-Point and a Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the relative amplitude response of each instrument to a traveling shockwave generated by a laser spark in air. The first FLDI instrument generated two slightly-separated measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated a measurement line that was oriented parallel to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along the line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement line is oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along the line. Numerical computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Brett F. Bathel↗

Hypersonic Fluid-Thermal-Structural Interactions on a Compression Ramp with an Embedded Compliant Panel

The fluid-thermal-structural interactions of a compliant panel embedded in a compression ramp are explored experimentally at Mach 6. The panel structural response is investigated for turbulent and transitional shock-wave/boundary-layer interactions at five distinct interaction strengths and up to four different pressure differentials. Upstream of the compression corner, fast-response piezoresistive pressure transducers show the feedback of the panel vibrations and static deflection on the upstream pressure fluctuations. The magnitude of the pressure fluctuation rms shows a reduction in the upstream disturbances when a pressure differential is applied across the compliant panel. Photogrammetry and IR thermography are used simultaneously to measure the panel deformations and surface temperature. Panel deformation, frequency shifting, and frequency bifurcation are consistent with post-thermal-buckling behavior.

hypersonic↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Advances in Stereo Photogrammetry Capabilities for in-Situ Ejecta Measurements in Lunar Plume-Surface Interactions

Plume-surface interaction is a critical topic of interest as human spaceflight programs establish a renewed presence on the Moon and push onwards to Mars. The erosion of regolith and high-speed ejection of soil and rocks which occurs during a powered spacecraft landing on lunar or terrestrial bodies can pose serious risks to the vehicle during landing and to existing ground assets. Ground testing campaigns have provided data sets in relevant environments (e.g., low pressure) in tandem with predictive computational model validation. To-date, limited in-situ flight data exists to inform the study of the key phenomena of plume-surface interaction: plume-flow physics, soil erosion, and ejecta dynamics. In two upcoming lunar missions, erosion of the lunar regolith will be measured in-situ using the stereo photogrammetry technique as part of NASA’s Commercial Lunar Payload Services (CLPS) Program. The Stereo Cameras for Lunar Plume Surface Studies (SCALPSS) will use a multiple-camera system to measure the erosion of the lunar regolith due to the vehicles’ rocket engine plumes during descent and after landing. The application of stereo photogrammetry to accurately measure a realistic eroded shape has been validated in laboratory work ahead of the scheduled flights. In preparation for future CLPS, Artemis, or other lunar science missions, recent advancements have been made to measure the ejecta structure and particle dynamics in addition to the erosion of regolith using a SCALPSS-like photogrammetry system. The thickness and ejection angle of entrained soil and dust produced during plume-induced erosion can be used to determine how far debris will travel, and thus how it may impact nearby infrastructure or the landing vehicle itself. The present work highlights the development of this new flight instrumentation capability and its value to advancements in the plume-surface interaction measurement topic for lunar or planetary landings.

Olivia K. Tyrrell↗

Self-Aligned Focusing Schlieren at the 0.3-M Transonic Cryogenic Tunnel and the National Transonic Facility

The implementation of a self-aligned focusing schlieren (SAFS) system at two cryogenic wind tunnels at NASA Langley Research Center is discussed. Risk-reduction testing of the SAFS system was first performed at the 0.3-M Transonic Cryogenic Tunnel to evaluate the system’s operation in a small-scale characteristic cryogenic facility. Testing was conducted with three models: a three-quarter span 25.4-mm-diameter cylinder, a semi-span 65A006 tapered unswept airfoil, and a full-span SC(3)-0712 airfoil. Testing with the cylinder and semi-span airfoil revealed a highly dynamic shock environment, whereas the shock on the full-span airfoil was stationary, solidifying the usage of this model for a pre-/post-shock particle tracking velocimetry measurement. Temperature-induced polarization-altering window stresses were encountered during low-temperature testing, and were mitigated using a “non-ideal” quartz/quartz Rochon prism that had largely been neglected since the SAFS system’s first introduction in favor of the more favorable “ideal” glass/quartz Rochon prism. The size of the SAFS system was then decreased in order to fit inside an environmentally-controlled camera can enclosure at the National Transonic Facility (NTF) for testing of a sting-mounted aircraft model. The SAFS system was demonstrated to be effective at filtering out the large density gradient flow in the 0.3-M plenum, and the thick, high density turbulent boundary layers on the wind tunnel walls at the NTF. Results of the testing campaigns and improvements to future systems are discussed.

Joshua M. Weisberger↗

Evaluation of a Laser-Dot Grid-Projection System for Lunar Lander Crater-Shape and Ejecta-Sheet Measurements

Development, testing, and evaluation of an active-illumination laser-dot grid-projection system was performed to evaluate its potential inclusion on an upcoming uncrewed lunar lander mission to the south pole region of the moon. Active illumination may be required for this mission due to the shallow angle of the sun at the landing location, which may cast shadows in the landing region, hindering the stereo camera imaging system’s ability to determine the pre-and post-landing lunar surface/crater shape. Testing includes characterization of the diffractive optical elements used for the grid projection, single-camera tests to determine the imaged laser dot intensity as a function of camera exposure and imaging angle relative to the laser grid projection, laser dot brightness/saturation impact on depth map calculations, angle of imaged laser grid impact on depth map calculations for steep crater edges, impact of density gradients on the depth map calculations, and the feasibility of making measurements of the ejecta sheet.

Joshua M. Weisberger↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O 2 was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M. Weisberger↗

Implementation of a Compact Self-Aligned Focusing Schlieren System for Measurements with the SBLT-II Flight Test Article

Previous flight testing of a supersonic natural laminar flow airfoil on the NASA F-15Baircraft showed evidence of multiple impinging shocks (shock train) of unknown origin, which generated sufficient crossflow on the airfoil to affect the primary measurement goal of transition location. A compact self-aligned focusing schlieren (SAFS) system is being developed to visualize this shock train on the forward surface of the Supersonic Boundary Layer Transition - PhaseII (SBLT-II) flight test article. Details of the design of the SAFS flight system, the constraints imposed by the imaging pod that will be mounted to the F-15B aircraft, preliminary laboratory results obtained with the system, and challenges associated with integrating the imaging system into the aircraft are presented. The resulting schlieren images obtained from this flight test will allow for a three-dimensional reconstruction of the unknown shock structure, validating the use of SAFS for flight testing.

Joshua M. Weisberger↗

Self-Aligned Focusing Schlieren and OH Planar Laser-Induced Fluorescence Flow Visualization in a Dual-Mode Scramjet

Ahigh-speed self-aligned focusing schlieren (SAFS) system was used to visualize density gradients in and around the cavity flameholder of the combustor section of the University of Virginia Supersonic Combustion Facility (UVASCF). Images with this system were acquired at a framing rate of 110 kHz with no fuel injection, with fuel injection but no flame, and for fuel injection with combustion corresponding to a global equivalence ratio of 𝜙 = 0.18. Images with an air throttle in operation to modify the shock train location with fuel injection and with flame were also acquired. Simultaneous OH planar laser-induced fluorescence (PLIF) images were also acquired at a framing rate of 20 Hz. Results obtained with both visualization techniques are compared to one another to highlight how SAFS can complement more advanced flow visualization techniques and resolve dynamic behavior that may not otherwise be captured. Both proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) analysis techniques are applied to the SAFS image sequences to identify coherent periodic structures for the runs with fuel injection and combustion.

Brett F Bathel↗

Recent Progress and Development of Self-Aligned Focusing Schlieren

A broad range of developments and applications of self-aligned focusing schlieren (SAFS)systems is presented. The replacement of the Ronchi ruling (RR) with a𝜇LCD was demonstrated with digital SAFS, which provides the ability to modulate the pattern and orientation without physical intervention. Additionally, replacement of the traditional RR with spectral-spatial filters was demonstrated to yield the ability to simultaneously image horizontal and vertical index of refraction gradients using two separate wavelengths. The application of the Scheimpflug principle to SAFS systems enables off-axis imaging and allowed for extended fields-of-view to be captured using a two-camera system. The addition of a plenoptic camera to a baseline SAFS system enables refocusing capabilities, which is demonstrated on two jets offset along the optical axis. Furthermore, application of an event-based camera to SAFS was shown to enable acquisition of sparse, spatio-temporal data. Beyond the listed developments, SAFS was applied to difficult and constraining facilities, such as the National Full-Scale Aerodynamics Complex(NFAC) 80- by 120-ft Wind Tunnel and the Thermal Acoustic Engines (TAE) rig at NASA Ames Research Center and NASA Glenn Research Center, respectively. Behavior of Ronchi rulings, Rochon prisms, and the use of quarter-wave plates versus quarter-wave films are evaluated to provide insight for future experimental design of SAFS-systems.

Self-Aligned Focusing Schlieren↗