Search NASASearch

Engineering topics

Juda, M.

Publications and source records attributed to Juda, M..

Optics Requirements For The Generation-X X-Ray Telescope

US, European, and Japanese space agencies each now operate successful X-ray missions -- NASA s Chandra, ESA s XMM-Newton, and JAXA s Suzaku observatories. Recently these agencies began a collaboration to develop the next major X-ray astrophysics facility -- the International X-ray Observatory (IXO) -- for launch around 2020. IXO will provide an order-of-magnitude increase in effective area, while maintaining good (but not sub-arcsecond) angular resolution. X-ray astronomy beyond IXO will require optics with even larger aperture areas and much better angular resolution. We are currently conducting a NASA strategic mission concept study to identify technology issues and to formulate a technology roadmap for a mission -- Generation-X (Gen-X) -- to provide these capabilities. Achieving large X-ray collecting areas in a space observatory requires extremely lightweight mirrors.

O'Dell, S. .

Exploring the Hot Galactic Halo Using Shadows of High Latitude Clouds

The objective of this proposal was to measure variations in the 1/4 keV emission from the galactic halo, using ROSAT (x-ray astronomy satellite) Position Sensitive Proportional Counters (PSPC) observations toward known enhancements in the absorbing column density along the line-of-sight out of the Galaxy. Target directions were selected to have a low total hydrogen column density but to also show significant gradients in the amount of absorbing material, as traced by Infrared Astronomical Satellite (IRAS) 100 micron emission, on angular scales that would be contained within the PSPC field of view. In addition, we restricted the galactic latitude of the target directions to be greater than 60 degrees or less than -60 degrees in order to enable a cleaner separation of Galactic halo emission from that of the Galactic disk. The observations would also provide a measurement of the brightness of the emission from the Local Bubble.

Juda, M.

Results of a Deep Chandra Observation of the Crab Nebula and Pulsar

The Crab Nebula and pulsar were observed for a total of 150 ksec with the LETG/HRC-S combination aboard the Chandra X-Ray Observatory in 2000, January and February. One of the principal aims of the experiment was to study the emission from the pulsar as a function of pulse phase. Neutron stars are believed to be formed with core temperatures of 10(exp 11) K. As the pulsar is the best studied of the young known neutron stars with an age of only 940 yrs, it should be possible to observe thermal emission from the hot stellar surface which in turn constrains equations of state. The pulsar, on the other hand, is a powerful non-thermal emitter, powering an X-ray bright synchrotron nebula which, in Einstein and ROSAT observations, overshadowed the fainter thermal surface emission. Making use of the high angular resolution provided by Chandra we were able to detect X-rays from the Crab-pulsar at all pulse phases. We discuss whether this detection is indeed of thermal emission or of a faint synchrotron component of the pulsed emission from the magnetosphere. We further comment on dynamical effects observed in the pulsar-wind outflow and the analysis of the LETG spectral data, especially near the oxygen edge.

Weisskopf, M. C.

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.

X ray microcalorimeters: Principles and performance

Microcalorimeters operating at cryogenic temperatures can be excellent X-ray spectrometers. They simultaneously offer very high spectral resolving power and high efficiency. These attributes are important for X-ray astronomy where most sources have low fluxes and where high spectral resolution is essential for understanding the physics of the emitting regions. The principles of operation of these detectors, limits to their sensitivity, design considerations, techniques of fabrication, and their performance as X-ray spectrometers, are reviewed.

Moseley, S. H.

The Diffuse X-ray Spectrometer Experiment

The Diffuse X-ray Spectrometer Experiment, or 'DXS', is designed to measure the spectrum of the low-energy diffuse X-ray background with about 10 eV energy resolution and 15-deg spatial resolution. During a 5-day Space Shuttle mission, DXS is to measure the spectrum of ten 15 x 15 deg regions lying along a single 150-deg-long great circle arc on the sky. DXS carries two large-area X-ray Bragg spectrometers for the 44-84 A wavelength range; these permit measurement of the wavelength spectrum of the cosmic low-energy diffuse X-ray background with good spectral resolution.

Sanders, W. T.

Thermal detectors for X-ray astronomy - Current performance and limitations

We have been developing thermal detectors for X-ray astronomy. These detectors have the advantages of both high energy resolution and high quantum efficiency. A practical detector operating at a temperature of 0.1 K could ideally have a resolution as good as 1 eV (FWHM). We have produced a detector with a measured resolution of 7 eV (FWHM) for 6 keV X-rays. The detailed behavior of the detector thermistor and thermal links impose limits on performance. Techniques for improving detector behavior will be discussed. We are currently constructing an instrument for launch on a sounding rocket to observe the soft X-ray emission from the interstellar medium.

Juda, M.

Limits on the density of neutral gas within 100 parsecs from observations of the soft X-ray background

Observations are presented in two soft X-ray bands, the Be band (0.077-0.111 keV) and the B-prime (0.105-0.188 keV), for nine directions in the sky. The ratio of count rates in these two bands remains constant as the rates vary by a factor of three, even though the effective interstellar absorption cross sections in the bands differ by a factor of about 3.5. For a model in which the bulk of the observed soft X-ray emission originates in a uniform low-density region surrounding the sun, the constant ratio between the band rates places an upper limit on the amount of neutral material that can be homogeneously mixed with the X-ray-emitting gas. The 2 sigma upper limit on the H I column density over an average path through the local emitting region is 6.6 x 10 to the 18th/sq cm. If the average path length is about 100 pc, then clouds similar to the one in which the sun is embedded could still have a filling factor as large as 25 percent.

Juda, M.

Thermal detection of X-rays

The development of calorimeters is described in terms of their proposed application to sounding-rocket investigations of cosmic X-ray sources. The fundamental theory of the energy resolution of the devices is given, and general discussions are presented regarding the limitations associated with the materials used and available thermometer types. Also given are data describing electrical nonlinearity as a function of temperature, thermistor sensitivity, and heat capacity, as well as data regarding the excess noise that aids in the conduction process. Cryogenic calorimeters based on doped semiconductor thermistors are found to be limited, although thermal detectors have important applications to high-resolution laboratory spectroscopy. Electrical nonlinearity and the excess noise are found to be important for obtaining optimum heat capacity in the thermistor.

Mccammon, D.

Observing soft X-ray line emission from the interstellar medium with X-ray calorimeter on a sounding rocket

For an X-ray calorimeter working at 0.1 K, the energy resolution ideally can be as good as one eV for a practical detector. A detector with a resolution of 17 eV FWHM at 6 keV has been constructed. It is expected that this can be improved by a factor of two or more. With X-ray calorimeters flown on a sounding rocket, it should be possible to observe soft X-ray line emission from the interstellar medium over the energy range 0.07 to 1 keV. Here, a preliminary design for an X-ray calorimeter rocket experiment and the spectrum which might be observed from an equilibrium plasma are presented. For later X-ray calorimeter sounding rocket experiments, it is planned to add an aluminum foil mirror with collecting area of about 400 sq cm to observe line features from bright supernova remnants.

Zhang, J.

Observations of the soft X-ray diffuse background at 0.1 keV

The results of a sounding rocket flight that observed the very soft X-ray diffuse background in a section of the northern Galactic hemisphere are presented. The ratio of the measured Be band count rates to the Wisconsin sky survey B band count rates is nearly constant over a 120 deg arc on the sky, strongly suggesting a common emission mechanism for both Be and B band X-rays. The mean free path is about seven times smaller for the Be band than for the B band. The present results imply that the neutral hydrogen column density between the emitting material and the earth varies by less than 2 x 10 to the 18th H I/sq cm over the observed region. It is concluded that such variations are unlikely unless the total intervening column density is less than a few times this value.

Bloch, J. J.

Thermal detectors for high resolution spectroscopy

Cryogenic microcalorimeters can be made sensitive enough to measure the energy deposited by a single particle or X-ray photon with an accuracy of about one electron volt. It may also be possible to construct detectors of several-kilograms mass whose resolution is only a few times worse than this. Data from relatively crude test devices are in good agreement with thermal performance calculations, and a total system noise of 11 eV FWHM has been obtained for a silicon detector operating at 98 mK. Observations of 35 eV FWHM for 6-keV X-rays with a different device have been made.

Mccammon, D.

Ultrasoft X-ray Background Observations of the Local Interstellar Medium

Preliminary results from a May 8, 1984 sounding rocket survey of the soft X-ray background are presented. The X-ray detectors are sensitive to X-rays in three soft X-ray bandpasses: 80 to 110 eV, 90 to 188 eV, and 284 to 532 eV (at 20% of peak response). The lowest energy X-rays in this range have a mean free path of order 10 to the 19th power/sq cm and provide information about the local interstellar medium. The count rate in the 80 to 110 eV energy band (the Be band) tracks the 90 to 188 (eV band (the B band) very well, indicating that the same approx. 1 million degree gas that is responsible for the B band emission may be responsible for the bulk of the Be band X-rays as well.

Sanders, W. T.