ATOMIC Simulations and Experimental Data for CaCO3 Mixtures

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [1] and are used to develop a statistical characterization of matrix effects. Our overall suite of simulations includes contains several sets of simulations: training and validation sets of simulations for three and four element mixtures of calcium, carbon, oxygen, and nitrogen (included to account for atmosphere) along with simulations of the individual elements. The 4-element simulations include the mixture of all four elements mentioned and for each of the four individual elements. The 3-element simulations include output for the mixture of calcium, carbon, oxygen and for these three individual elements. The training data were produced using a 600-run design, shown in Figure 1, that varies input parameters temperature (T), electron density (Ne), and proportion of the elements calcium, carbon, oxygen, and nitrogen (Ca; C; O; N) for the 4 element output. The 3-element output includes all parameters except for the proportion of nitrogen. The element proportions (all the variables but T and Ne) sum to one and are unused in the single-element simulations. The validation data was produced with a 80-run design shown in Figure 2. The training and validation simulation outputs for the 4-element simulations for the mixture and for the single element calcium are shown as sample simulations in Figures 3 and 4 respectively. The simulations produce spectra over a range of 190nm - 950nm that roughly mimics the range collected by the SciAps Z-300 LIBS instrument that was used for the experimental data. The measured spectra for a CaCO3 (which may include contribution from Earth's atmosphere) in the experiment is shown in in Figure 5. All files are kept in directories whose names indicate the elemental composition (CaCO3, Ca, C, O, or N), number of elements (3 or 4), and purpose (training, which is not labeled in the file name, or validation) with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file. [1] J Colgan, EJ Judge, DP Kilcrease, and JE Barefield II. Ab-initio modeling of an iron laser-induced plasma: Comparison between theoretical and experimental atomic emission spectra. Spectrochimica Acta Part B: Atomic Spectroscopy, 97:65{73}, 2014.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ATOMIC Simulations and Experimental Data for Basalt-like Compounds

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [2]. The makeup of the plasma was considered to be divided into some proportion water, some proportion Martian atmosphere (CO2), and some proportion target (from the rock or object impacted by the laser), where these proportions add to 1. Based on expert knowledge, the proportion of water was kept in the range [0.0,0.5] and the proportion of atmosphere was kept in the range [0.02, 0.9]. Our overall suite of simulations contains six sets of simulations that differ in which elements were considered to make up the target. Within each set, we used uniformly drawn temperatures and log mass densities within pre-specified ranges. The temperature range was [0.5,1.5] eV and the log (base 10) mass density range was [-7,-4]. The proportion of water, atmosphere, and target were drawn from a symmetric Dirichlet distribution, but draws in which the propor- tion of water or atmosphere exceeded the pre-specified limits were rejected from the design. Up to eleven constituent elements (Si, Al, Fe, Mg, Ca, O, Ti, Mn, Na, K, P) were considered for the target, as they are the most common elements found in basalt compounds and were used in [1]. For each run, the proportions of the constituent elements making up the target were drawn from a symmetric Dirichlet distribution. We ran 1,350 simulations that included nonzero proportions of all eleven elements. We also ran simulations which excluded some of these elements. In particular, we ran 1,000 simulations that only included nonzero proportions for the six most common elements (Si, Al, Fe, Mg, Ca, O). We also ran five sets, each with 500 simulations, that only included nonzero proportions for five of the six most common elements (but where all sets included O). Thus, we generated a total of 4,850 spectra representing basalt-like compounds in which the target was comprised of oxygen and between four and ten other elements. The ATOMIC code produced spectra over a range of 240nm - 880nm that roughly mimics the range collected by the ChemCam instrument on the Mars rover Curiosity. Each spectra had 32,000 wavelengths split across three spectrometer ranges (to mimic ChemCam). The experimental data, described in [1], measures a prepared basalt sample. All files are kept in directories whose names indicate the set of elements considered for the target with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file which contains a header with measurement information, followed by a collection of 50 shots across a collection of wavelengths, along with the computed median and mean across shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ATOMIC Simulations and Experimental Data for Sodium and Copper Mixtures

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [1]. Our overall suite of simulations contains 12 sets of simulations: training and validation sets of simulations for each of two resolutions of each of sodium, copper, and mixtures of the two. The training data were produced using a 500-run design that varies input parameters temperature (T), electron density (Ne), proportion of sodium (pNa), and proportion of copper (pCu). The latter two variables sum to one and are unused in the single-element simulations. The validation data was produced with a 25-run design. The coarse simulations produce spectra over a range of 240nm - 880nm that roughly mimics the range collected by the ChemCam instrument on the Mars rover Curiosity. The fine resolution simulations produce spectra over a range of 550nm to 600nm and were produced to mimic the included experimental results. The experimental results cover four mixtures of sodium and copper. All data sets are kept in zip files whose names indicate the elemental composition (NaCu, Na, or Cu), resolution (coarse or fine), and purpose (training or validation) with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file. See attached abstract for figures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural differences between single crystal and polycrystalline UBe 13

Here, we report on observations of structural and chemical differences between samples of UBe 13 that were synthesised using two different methods. Unexplained discrepancies in properties between samples with differing synthesis had previously been found in this heavy fermion superconductor. A polycrystalline UBe 13 sample was made by arc-melting the constituents. Single crystals were grown using an aluminium flux and had a consistently slightly larger lattice parameter than the polycrystals, which merited further study. Neutron diffraction data were collected at the Lujan Center at LANSCE on the HIPPO diffractometer. Aluminium was detected by inductively coupled plasma mass spectrometry (ICP-MS) in the flux-grown single crystal (0.803 wt%), and small amounts (~0.2 wt%) of thorium were detected in the UBe 13 polycrystalline sample. In order to probe the implications of the presence of Al, calculations by spin-polarised DFT-GGA+U show that the incorporation of Al onto the 96i site (the lowest symmetry site in the structure) is energetically more favourable than on other sites. In general, the trends calculated by DFT for bond lengths and lattice parameter increases are consistent with bond lengths experimentally observed by neutron diffraction, but specific percentage changes with aluminium incorporation may be obscured by the unexpected thorium in the polycrystalline sample. The aggregate of our initial observations suggests that incorporation of aluminium from the flux into single crystal UBe 13 is significant.

36 MATERIALS SCIENCE↗

Comparative Assessment of Copper-Coated Kapton: Analysis of Microclad from Several Manufacturing Lots

Microclad is a composite material consisting of a thin copper coating applied on a single side over a Kapton substrate. Kapton is the commercial designator for polyimide supplied by DuPont. Microclad is a key material in detonator manufacture and function. Detonators which utilize Microclad function when a large current applied through a thin bridge etched into the copper produces a plasma, accelerating a Kapton flyer into an explosive (PETN) pellet. The geometry and properties of the Microclad are a critical element of this process.

36 MATERIALS SCIENCE↗

Comparison of femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements

Feasibility tests were conducted using femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for rapid uranium isotopic measurements. The samples used in this study consisted of a range of pg quantities of known 235/238 U solutions as dried spot residues of 300 pL drops on silicon substrates. The samples spanned the following enrichments of 235 U: 0.5, 1.5, 2, 3, and 15.1%. In this direct comparison using these particular samples both pulse durations demonstrated near equivalent data can be produced on either system with respect to accuracy and precision. There is no question that either LA-ICP-MS method offers the potential for rapid, accurate and precise isotopic measurements of U10Mo materials whether DU, LEU or HEU. The LA-ICP-MS equipment used for this work is commercially available. The program is in the process of validating this work for large samples using center samples strips from Y-12 MP-1 LEU-Mo Casting #1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Spectroscopy Capabilities:Application to Nuclear Forensics, Nuclear Detection, Nuclear Safeguards, Oil Industry, Material Identification and Analysis, and Sustainable Agricultural Nutrient Analysis

We have been very successful in measuring and analyzing actinides and actinide containing material for concentration ranges as low as 100 ppm to metal alloys. Several publications and LA-UR spectral line assignment references have been generated from this effort and listed below (1-6).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANL Testing of DTRA Sponsored ARA Portable LIBS Instruments: Isotopic Module [Slides]

The samples were stationary (not rastered during the experiment). Therefore the laser drilled through the powder sample the adhesive and to , the laser drilled through the powder sample, the adhesive and to the substrate (which can be seen in the photograph). <10 laser shots actually ablated sample. The remaining ~50 laser shots added to the spectral noise decreasing the S/N and making an accurate , decreasing the S/N and making an accurate determination of LOD difficult. If the number of laser shots are decreased, the amount of noise will be reduced increasing the S/N and most likely lower the LOD , increasing the S/N and, most likely, lower the LOD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗