Jung, H

Publications and source records attributed to Jung, H.

At least 19 records

Center for Frontiers of Subsurface Energy Security (Final Report)

For the past two decades a slowly growing consensus has been that rising temperature is being caused by increases in carbon dioxide (CO 2 ) in the Earth’s atmosphere. What is less consensual is what to do about it. Solutions range from reducing emissions to various ways to capture CO 2 (from effluents of power plants, as plants, etc.) and store it away from the atmosphere. The problem is of such magnitude that it is likely that we will need many methods. Also some methods would cause draconian harm to global economies. This work is about the storage part of the reducing of CO 2 in the atmosphere. There have been many methods proposed for storing CO 2 : in vegetation, at the bottom of oceans, in land farms, and in subsurface formations. The latter is particularly prominent given the large estimated volume in porous formation in the Earth, and the 50-year old experience in injecting CO 2 for enhanced oil recovery. This report is about the science behind subsurface storage, called here geological carbon storage or GCS. Effective GCS requires that billions of metric tons of CO 2 be injected into storage reservoirs annually. GCS feasibility requires balancing the opposing impacts of large emplacement (injection) rates without compromising caprock seal integrity during injection. Once injected, the challenge is to assure the injected CO 2 remains permanently stored. Under most conditions, CO 2 is in a supercritical state, or scCO 2 . scCO 2 is immiscible with the subsurface brine and has a factor of ten smaller viscosity, leading to the development of two-phase fluid flow and scCO 2 bypassing. After the injection of large volumes of scCO 2 , the pore pressure, state of stress, chemical, thermal, and biological steady-state or equilibrium conditions in the subsurface are disrupted, which may lead to unpredictable behavior because the responses to these changes are often non-linear. Current challenges for efficient and reliable scCO 2 storage are: (1) sustaining large injection rates; (2) using available pore space efficiently, and (3) controlling undesired or unexpected behavior, such as scCO 2 leakage. Various aspects of these challenges are addressed by collaborative projects within Center for Frontiers in Subsurface Energy Security (CFSES). Challenge 1 – Sustaining large storage rates. To offset the annual CO 2 emissions of in the United States, ~7 billion metric tons of CO 2 must be injected into the storage reservoirs annually. Injected CO 2 forms a plume that starts spreading, displacing originally resident brine, though inefficiently so. Because of its low viscosity, and buoyant forces, a CO 2 plume rises to the reservoir rock-caprock interface. Injecting large volumes of scCO 2 at sufficiently high rates into subsurface storage formations leads to increases in pore pressures, potential expansion of the reservoir rock, and may result in fracturing of the reservoir rock and/or caprock. CFSES research uses existing and new experimental and modeling approaches to identify chemical-physical controls on the permeability and pore pressure dynamics, anticipating geomechanical (fracturing) events, predicting multi-phase flow patterns and trapping of CO 2 . Challenge 2 – Using pore space with unprecedented efficiency. Since large volumes of scCO 2 are to be stored, the volume available in storage reservoirs must be used efficiently. Storage efficiency is defined as a fraction of pore space occupied by carbon dioxide. Current estimates are that less than 5 percent of available pore volume is available for storage because scCO 2 , having a smaller density and viscosity than reservoir brine, tends to form viscous fingers, and bypass available pore space. This flow regime results in a CO 2 plume spreading over large areas in subsurface. The research goal in Challenge 2 is to advance the fundamental understanding of two-phase flow through porous media, including molecular-to meter- scale experimental and modeling approaches. This work leads to novel strategies to ensure that injected CO 2 occupies more than 5% of the pore space, ideally up to 50%. Challenge 3 – Controlling undesired or unexpected behavior. Following the injection of scCO 2 , the subsurface reservoir re-equilibrates to different physical and chemical states. This re-equilibration in space and time could lead to unexpected and/or undesired behavior: fracturing of reservoir rock and/or caprock, development of preferential flow paths, CO 2 leakage (to the surface or overlaying fresh water reservoirs), induced seismicity, and activation of faults. One of the main research goals of CFSES was to advance the fundamental understanding of how individual chemical and physical processes are coupled. We particularly focused on the chemical-mechanical coupling, and flow-mechanical coupling. We collected experimental and modeling data to determine the temporal and spatial scales of the coupled processes, which may lead to pore collapse caused by creep, activation of fractures and faults, chemically-induced fracture propagation, and self-focusing of scCO 2 flow.

54 ENVIRONMENTAL SCIENCES↗

Failure mode analysis of the FFTF heating and ventilation system 25

This document was prepared as a supplemental study to Chapter 9.4 of the FFTF Final Safety Analysis Report and is included as a Category A reference in FFTF System Design Description 25, Heating and Ventilation System. It contains the single failure mode analysis on all the heating and ventilation systems that are essential to the safety of the plant, and confirms the adequacy of the system design to accommodate single failures without jeopardizing overall plant safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-I-78: Design of Diagnostic Multileaf Collimator Based On the Monte Carlo Simulation for Dose Reduction of Diagnostic Radiography

Purpose: A diagnostics Multileaf Collimator (MLC) was designed for diagnostic radiography dose reduction. Monte Carlo simulation was used to evaluate efficiency of shielding material for producing leaves of Multileaf collimator. Material & Methods: The general radiography unit (Rex-650R, Listem, Korea) was modeling with Monte Carlo simulation (MCNPX, LANL, USA) and we used SRS-78 program to calculate the energy spectrum of tube voltage (80, 100, 120 kVp). The shielding materials was SKD 11 alloy tool steel that is composed of 1.6% carbon(C), 0.4% silicon (Si), 0.6% manganese (Mn), 5% chromium (Cr), 1% molybdenum (Mo), and vanadium (V). The density of it was 7.89 g/m3. We simulated leafs diagnostic MLC using SKD 11 with general radiography unit. We calculated efficiency of diagnostic MLC using tally6 card of MCNPX depending on energy. Results: The diagnostic MLC consisted of 25 individual metal shielding leaves on both sides, with dimensions of 10 × 0.5 × 0.5 cm3. The leaves of MLC were controlled by motors positioned on both sides of the MLC. According to energy (tube voltage), the shielding efficiency of MLC in Monte Carlo simulation was 99% (80 kVp), 96% (100 kVp) and 93% (120 kVp). Conclusion: We certified efficiency of diagnostic MLC fabricated from SKD11 alloy tool steel. Based on the results, the diagnostic MLC was designed. We will make the diagnostic MLC for dose reduction of diagnostic radiography.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-159: Monte Carlo Simulation Studies of Three-Dimensional Dose Distribution for Polymer Gel Dosimeter and Radiochromic Gel Dosimeter in a Proton Beam

Purpose: The purpose of this simulation study is to evaluate the proton detectability of gel dosimeters, and estimate the three-dimensional dose distribution of protons in the radiochromic gel and polymer gel dosimeter compared with the dose distribution in water. Methods: The commercial composition ratios of normoxic polymer gel and LCV micelle radiochromic gel were included in this simulation study. The densities of polymer and radiochromic gel were 1.024 and 1.005 g/cm3, respectively. The 50, 80 and 140 MeV proton beam energies were selected. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX 2.7.0, Los Alamos Laboratory). The water equivalent depth profiles and the dose distributions of two gel dosimeters were compared for the water. Results: In case of irradiating 50, 80 and 140 MeV proton beam to water phantom, the reference Bragg-peak depths are represented at 2.22, 5.18 and 13.98 cm, respectively. The difference in the water equivalent depth is represented to about 0.17 and 0.37 cm in the radiochromic gel and polymer gel dosimeter, respectively. The proton absorbed doses in the radiochromic gel dosimeter are calculated to 2.41, 3.92 and 6.90 Gy with increment of incident proton energies. In the polymer gel dosimeter, the absorbed doses are calculated to 2.37, 3.85 and 6.78 Gy with increment of incident proton energies. The relative absorbed dose in radiochromic gel (about 0.47 %) is similar to that of water than the relative absorbed dose of polymer gel (about 2.26 %). In evaluating the proton dose distribution, we found that the dose distribution of both gel dosimeters matched that of water in most cases. Conclusion: As the dosimetry device, the radiochromic gel dosimeter has the potential particle detectability and is feasible to use for quality assurance of proton beam therapy beam.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-104: Evaluation of Accuracy for Various Deformable Image Registrations with Virtual Deformation QA Software

Purpose: The accuracy of deformable image registration (DIR) has a significant dosimetric impact in radiation treatment planning. We evaluated accuracy of various DIR algorithms using virtual deformation QA software (ImSimQA, Oncology System Limited, UK). Methods: The reference image (Iref) and volume (Vref) was first generated with IMSIMQA software. We deformed Iref with axial movement of deformation point and Vref depending on the type of deformation that are the deformation1 is to increase the Vref (relaxation) and the deformation 2 is to decrease the Vref (contraction) .The deformed image (Idef) and volume (Vdef) were inversely deformed to Iref and Vref using DIR algorithms. As a Result, we acquired deformed image (Iid) and volume (Vid). The DIR algorithms were optical flow (HS, IOF) and demons (MD, FD) of the DIRART. The image similarity evaluation between Iref and Iid was calculated by Normalized Mutual Information (NMI) and Normalized Cross Correlation (NCC). The value of Dice Similarity Coefficient (DSC) was used for evaluation of volume similarity. Results: When moving distance of deformation point was 4 mm, the value of NMI was above 1.81 and NCC was above 0.99 in all DIR algorithms. Since the degree of deformation was increased, the degree of image similarity was decreased. When the Vref increased or decreased about 12%, the difference between Vref and Vid was within ±5% regardless of the type of deformation. The value of DSC was above 0.95 in deformation1 except for the MD algorithm. In case of deformation 2, that of DSC was above 0.95 in all DIR algorithms. Conclusion: The Idef and Vdef have not been completely restored to Iref and Vref and the accuracy of DIR algorithms was different depending on the degree of deformation. Hence, the performance of DIR algorithms should be verified for the desired applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-299: Dosimetric Characterization of Small Field in Small Animal Irradiator with Radiochromic Films

Purpose: The small animal irradiator has been used with small animals to optimize new radiation therapy as preclinical studies. The small animal was irradiated by whole- or partial-body exposure. In this study, the dosimetric characterizations of small animal irradiator were carried out in small field using Radiochromic films Material & Methods: The study was performed in commercial animal irradiator (XRAD-320, Precision x-ray Inc, North Brantford) with Radiochromic films (EBT2, Ashland Inc, Covington). The calibration curve was generated between delivery dose and optical density (red channel) and the films were scanned by and Epson 1000XL scanner (Epson America Inc., Long Beach, CA).We evaluated dosimetric characterization of irradiator using various filter supported by manufacturer in 260 kV. The various filters were F1 (2.0mm Aluminum (HVL = about 1.0mm Cu) and F2 (0.75mm Tin + 0.25mm Copper + 1.5mm Aluminum (HVL = about 3.7mm Cu). According to collimator size (3, 5, 7, 10 mm, we calculated percentage depth dose (PDD) and the surface –source distance(SSD) was 17.3 cm considering dose rate. Results: The films were irradiated in 260 kV, 10mA and we increased exposure time 5sec. intervals from 5sec. to 120sec. The calibration curve of films was fitted with cubic function. The correlation between optical density and dose was Y=0.1405 X{sup 3}−2.916 X{sup 2}+25.566 x+2.238 (R{sup 2}=0.994). Based on the calibration curve, we calculated PDD in various filters depending on collimator size. When compared PDD of specific depth (3mm) considering animal size, the difference by collimator size was 4.50% in free filter and F1 was 1.53% and F2 was within 2.17%. Conclusion: We calculated PDD curve in small animal irradiator depending on the collimator size and the kind of filter using the radiochromic films. The various PDD curve was acquired and it was possible to irradiate various dose using these curve.

60 APPLIED LIFE SCIENCES↗

SU-E-T-753: Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code

Purpose: The purpose of this study is to estimate the three-dimensional dose distributions in the polymer and the radiochromic gel dosimeter, and to identify the detectability of both gel dosimeters by comparing with the water phantom in case of irradiating the proton particles. Methods: The normoxic polymer gel and the LCV micelle radiochromic gel were used in this study. The densities of polymer and the radiochromic gel dosimeter were 1.024 and 1.005 g/cm{sup 3}, respectively. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX, Los Alamos National Laboratory). The shape of phantom irradiated by proton particles was a hexahedron with the dimension of 12.4 × 12.4 × 15.0 cm{sup 3}. The energies of proton beam were 50, 80, and 140 MeV energies were directed to top of the surface of phantom. The cross-sectional view of proton dose distribution in both gel dosimeters was estimated with the water phantom and evaluated by the gamma evaluation method. In addition, the absorbed dose(Gy) was also calculated for evaluating the proton detectability. Results: The evaluation results show that dose distributions in both gel dosimeters at intermediated section and Bragg-peak region are similar with that of the water phantom. At entrance section, however, inconsistencies of dose distribution are represented, compared with water. The relative absorbed doses in radiochromic and polymer gel dosimeter were represented to be 0.47 % and 2.26 % difference, respectively. These results show that the radiochromic gel dosimeter was better matched than the water phantom in the absorbed dose evaluation. Conclusion: The polymer and the radiochromic gel dosimeter show similar characteristics in dose distributions for the proton beams at intermediate section and Bragg-peak region. Moreover the calculated absorbed dose in both gel dosimeters represents similar tendency by comparing with that in water phantom.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗

SU-E-I-49: The Evaluation of Usability of Multileaf Collimator for Diagnostic Radiation in Cephalometric Exposure

Purpose: This study evaluated usability of Multileaf collimator (MLC) for diagnostic radiation in cephalometric exposure using optical stimulated luminance dosimeters (OSLDs) Methods: The MLC material was made alloy tool steel (SKD-11) and the density of it is 7.89g/m3 that is similar to it of steel (Fe, 7.85 g/m3) and the MLC was attached to general radiography unit (Rex-650R, Listem Inc, Korea) for cephalometric exposure. The OSLDs that used were nanoDotTM Dosimeter (Landauer Inc, Glenwood, USA) and we read out OSLDs with micro star system (Landauer Inc, Glenwood, USA). The Optical annealing system contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To measure absorbed dose using OSLDs, was carried out dosimetric characteristics of OSLDs. Based on these, we evaluated dose reduction of critical organ (Eyes, Thyroids) with MLC in cephalometric exposure Results: The dosimetric characteristics were following that batch homogeneity was 1.21% and reproducibility was 0.96% of the coefficient of variation The linearity was that the correlation of between dose and count was fitted by linear function (dose,mGy = 0.00029 × Count, R2 =0.997). The range of angular dependence was from −3.6% to 3.7% variation when each degree was normalized by zero degree. The organ dose of Rt. eye, Lt eye, thyroids were 77.8 μGy, 337.0 μGy, 323.1μGy, respectively in open field and the dose reduction of organ dose was 10.6%(8.3μGy), 12.4 %(42 μGy), 87.1%(281.4μGy) with MLC Conclusion: We certified dose reduction of organ dose in cephalometric exposure. The dose reduction of Eye was 11% because of reduction of field size and it of thyroids was 87% by primary beam shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-130: Dosimetric Evaluation of Tissue Equivalent Gel Dosimeter Using Saccharide in Radiotherapy System

Purpose: In this study, the dose responses of the MAGIC gel with various concentrations and type of saccharide are examined to clarify the roles of mono and disaccharide in the polymerization process. Then we focused on the tissue equivalence and dose sensitivity of MAGIC gel dosimeters. Methods: The gel is composed of HPLC, 8% gelatin, 2 × 10-3 M L-ascorbic acid, 1.8 × 10-2 M hydroquinone, 8 × 10-5 M copper(II)sulfate and 9% methacrylic acid, new polymer gels are synthesized by adding glucose(monosaccharide), sucrose(disaccharide) and urea in the concentration range of 5∼35%. For irradiation of the gel, cesium-137 gamma-ray irradiator was used, radiation dose was delivered from 5∼50 Gy. MRI images of the gel were acquired by using a 3.0 T MRI system. Results: When saccharide and urea were added, the O/C, O/N and C/N ratios agreed with those of soft tissue with 1.7%. The dose-response of glucose and sucrose gel have slope-to-intercept ratio of 0.044 and 0.283 respectively. The slope-to-ratio is one important determinant of gel sensitivity. R-square values of glucose and sucrose gel dosimeters were 0.984 and 0.994 respectively. Moreover when urea were added, the slope-to-intercept ratio is 0.044 and 0.073 respectively. R-square values of mono and disaccharide gel were 0.973 and 0.989 respectively. When a saccharide is added into the MAGIC gel dosimeter, dose sensitivity is increased. However when urea were added, dose sensitivity is slightly decreased. Conclusion: In this study, it was possible to obtain the following conclusions by looking at the dose response characteristics after adding mono-, di-saccharide and urea to a MAGIC gel dosimeter. Saccharide was a tendency of increasing dose sensitivity with disaccharide. Sa.ccharide is cost effective, safe, soft tissue equivalent, and can be used under various experimental conditions, making it a suitable dosimeter for some radiotherapy applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-243: MonteCarlo Simulation Study of Polymer and Radiochromic Gel for Three-Dimensional Proton Dose Distribution

Purpose: To estimate the three dimensional dose distributions in a polymer gel and a radiochromic gel by comparing with the virtual water phantom exposed to proton beams by applying Monte Carlo simulation. Methods: The polymer gel dosimeter is the compositeness material of gelatin, methacrylic acid, hydroquinone, tetrakis, and distilled water. The radiochromic gel is PRESAGE product. The densities of polymer and radiochromic gel were 1.040 and 1.0005 g/cm3, respectively. The shape of water phantom was a hexahedron with the size of 13 × 13 × 15 cm3. The proton beam energies of 72 and 116 MeV were used in the simulation. Proton beam was directed to the top of the phantom with Z-axis and the shape of beam was quadrangle with 10 × 10 cm2 dimension. The Percent depth dose and the dose distribution were evaluated for estimating the dose distribution of proton particle in two gel dosimeters, and compared with the virtual water phantom. Results: The Bragg-peak for proton particles in two gel dosimeters was similar to the virtual water phantom. Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in the identical region (4.3 cm) for 72 MeV proton beam. For 116 MeV proton beam, the Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in 9.9, 9.9 and 9.7 cm, respectively. The dose distribution of proton particles in polymer gel, radiochromic gel, and virtual water phantom was approximately identical in the case of 72 and 116 MeV energies. The errors for the simulation were under 10%. Conclusion: This work indicates the evaluation of three dimensional dose distributions by exposing proton particles to polymer and radiochromic gel dosimeter by comparing with the water phantom. The polymer gel and the radiochromic gel dosimeter show similar dose distributions for the proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulated dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.

60 APPLIED LIFE SCIENCES↗

Helical Nanofilament Phases

In the formation of chiral crystals, the tendency for twist in the orientation of neighboring molecules is incompatible with ordering into a lattice: Twist is expelled from planar layers at the expense of local strain. We report the ordered state of a neat material in which a local chiral structure is expressed as twisted layers, a state made possible by spatial limitation of layering to a periodic array of nanoscale filaments. Although made of achiral molecules, the layers in these filaments are twisted and rigorously homochiral - a broken symmetry. The precise structural definition achieved in filament self-assembly enables collective organization into arrays in which an additional broken symmetry - the appearance of macroscopic coherence of the filament twist-produces a liquid crystal phase of helically precessing layers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Higgs production via gluon fusion in k{sub T} factorisation

Theoretical studies of Higgs production via gluon fusion are frequently carried out in the limit where the top quark mass is much larger than the Higgs mass, an approximation which reduces the top quark loop to an effective vertex. We present a numerical analysis of the error thus introduced by performing a Monte Carlo calculation for gg{yields}h in k{sub T}-factorisation, using the parton shower generator CASCADE. By examining both inclusive and exclusive quantities, we find that retaining the top-mass dependence results in only a small enhancement of the cross-section. We then proceed to compare CASCADE to the collinear Monte Carlos PYTHIA, MC-NLO and POWHEG.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The driving frequency effects on the atmospheric pressure corona jet plasmas from low frequency to radio frequency

Lately, the atmospheric pressure jet type corona plasma, which has been typically driven by dc to low frequency (LF: several tens of kHz), is often generated by using radio frequency of 13.56 MHz. Yet, the relationship between the plasma and its driving frequency has seldom been investigated. Hence, in this study, dependence of the atmospheric pressure corona plasma characteristics on the driving frequency was explored experimentally from LF to rf (5 kHz-13.56 MHz). The plasmas generated by the driving frequency under 2 MHz were cylindrical shape of several tens of millimeters long while the 13.56 MHz plasma is spherical and a few millimeters long. As the driving frequency was increased, the plasma length became shortened. At the lower driving frequencies (below 2 MHz), the plasmas existed as positive streamer and negative glow for each half period of the applied voltage, but the discharge was more continuous in time for the 13.56 MHz plasma. It was inferred from the measured I-V curves that the higher driving frequency induced higher discharge currents, and the gas temperature was increased as the driving frequency was increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗