Search NASA⌕ Search

Engineering topics

Jungquist, R.

Publications and source records attributed to Jungquist, R..

Characterization of shaped Bragg crystal assemblies for narrowband x-ray imaging

X-ray imaging using shaped crystals in Bragg reflection is a powerful technique used in high-energy-density physics experiments. The characterization of these crystal assemblies with conventional x-ray sources is very difficult because of the required angular resolution of the order of ~10 μrad and the narrow bandwidth of the crystal. The 10-J, 1-ps Multi-Terawatt (MTW) laser at the Laboratory for Laser Energetics was used to characterize a set of Bragg crystal assemblies. The small spot size (of the order of 5 μm) and the high power (>10 18 W/cm 2 ) of this laser make it possible to measure the spatial resolution at the intended photon energy. A set of six crystals from two different vendors was checked on MTW, showing an unexpectedly large variation in spatial resolution of up to a factor of 4.

47 OTHER INSTRUMENTATION↗

Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager

A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new streaked soft x-ray imager for the National Ignition Facility

Here, a new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF’s x-ray streak cameras, record a 4× magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 μm. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300–510 eV and 200–400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.

42 ENGINEERING↗

Measurements of the ablation-front trajectory and low-mode nonuniformity in direct-drive implosions using x-ray self-emission shadowgraphy

Self-emission x-ray shadowgraphy provides a method to measure the ablation-front trajectory and low-mode nonuniformity of a target imploded by directly illuminating a fusion capsule with laser beams. The technique uses time-resolved images of soft x-rays (> 1 keV) emitted from the coronal plasma of the target imaged onto an x-ray framing camera to determine the position of the ablation front. Methods used to accurately measure the ablation-front radius ( ${\it\delta}R=\pm 1.15~{\rm\mu}\text{m}$ ), image-to-image timing ( ${\it\delta}({\rm\Delta}t)=\pm 2.5$ ps) and absolute timing ( ${\it\delta}t=\pm 10$ ps) are presented. Angular averaging of the images provides an average radius measurement of ${\it\delta}(R_{\text{av}})=\pm 0.15~{\rm\mu}\text{m}$ and an error in velocity of ${\it\delta}V/V=\pm 3\%$ . This technique was applied on the Omega Laser Facility and the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shell trajectory measurements from direct-drive implosion experiments

A technique to measure the shell trajectory in direct-drive inertial confinement fusion implosions is presented. The x-ray self emission of the target is measured with an x-ray framing camera. Optimized filtering limits the x-ray emission from the corona plasma, isolating a sharp intensity gradient very near the ablation surface. This enables one to measure the radius of the imploding shell with an accuracy better than 1 {mu}m and to determine a 200-ps average velocity to better than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗