Search NASA⌕ Search

Engineering topics

K H Kim

Publications and source records attributed to K H Kim.

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Geometric Analysis and Visualization of Maxillofacial Anthropometry

As part of head borne systems, the maxillofacial and mandibular components are critical for Soldier protection in extreme and dynamic conditions. Often this equipment must not only cover the lower face of the wearer, but also accommodate motion of the lower jaw and resultant deformation of the face shape. Although the application is different, head borne equipmentdesigned for astronauts has similarly critical design requirements including comfort and protection from other environmental hazards while allowing for maximum performance. To improve the design of such systems and to ensure adequate accommodation of the user population, NASA Johnson Space Center is collaborating with the U.S. Army’s Development Command Soldier Center (DEVCOM SC) to statistically analyze facial landmark and measurement data from large Soldier anthropometric databases ( ANSUR 1988 and ANSUR II). Anthropometric measurements were incorporated from 5383 males and 3594 females for analysis, including individuals aged 17-58 across a range of races. Facial landmarks were analyzed, specifically the 3D coordinates of the Menton, Prementon, Gonion, Tragion, Stomion, Zygion, Pronasale, and Subnasale. These data were statistically correlated with demographiccharacteristics, such as sex and population origin. A statistical model of the lower head-face surface geometry is currently in development to describe the variance of head and face shape across the population. The model will be able to visually show the statistical trends of the different shapes and sizes of the head, along with the synthetically represented boundary cases. The specific analytical methods and outcomes will be detailed in the final proceeding. This study will provide a more comprehensive assessment of how face shape varies across the military population compared to traditional linear measurements. The outcome of this study is expected to provide critical insight and recommendations for improved protective equipment design and development, not only with Soldiers but also astronauts in future exploration missions, as well as first responders and others that require critical equipment fitted to the maxillofacial and or mandibular region.

W Green↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗