Search NASA⌕ Search

Engineering topics

Kabadi, N.

Publications and source records attributed to Kabadi, N..

Evidence of non-Maxwellian ion velocity distributions in spherical shock-driven implosions

The ion velocity distribution functions of thermonuclear plasmas generated by spherical laser direct drive implosions are studied using deuterium-tritium (DT) and deuterium-deuterium (DD) fusion neutron energy spectrum measurements. A hydrodynamic Maxwellian plasma model accurately describes measurements made from lower temperature (< 10 keV), hydrodynamiclike plasmas, but is insufficient to describe measurements made from higher temperature more kineticlike plasmas. The high temperature measurements are more consistent with Vlasov-Fokker-Planck (VFP) simulation results which predict the presence of a bimodal plasma ion velocity distribution near peak neutron production. Furthermore, these measurements provide direct experimental evidence of non-Maxwellian ion velocity distributions in spherical shock driven implosions and provide useful data for benchmarking kinetic VFP simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of ion-electron energy-transfer cross section in high-energy-density plasmas

Here, we report on measurements of the ion-electron energy-transfer cross section utilizing low-velocity ion stopping in high-energy-density plasmas at the OMEGA laser facility. These measurements utilize a technique that leverages the close relationship between low-velocity ion stopping and ion-electron equilibration. Shock-driven implosions of capsules filled with D 3 He gas doped with a trace amount of argon are used to generate densities and temperatures in ranges from 1 × 10 23 to 2 × 10 24 cm –3 and from 1.4 to 2.5 keV, respectively. The energy loss of 1-MeV DD tritons and 3.7-MeV D 3 He alphas that have velocities lower than the average velocity of the thermal electrons is measured. The energy loss of these ions is used to determine the ion-electron energy-transfer cross section, which is found to be in excellent agreement with quantum-mechanical calculations in the first Born approximation. This result provides an experimental constraint on ion-electron energy transfer in high-energy-density plasmas, which impacts the modeling of alpha heating in inertial confinement fusion implosions, magnetic-field advection in stellar atmospheres, and energy balance in supernova shocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extension of charged-particle spectrometer capabilities for diagnosing implosions on OMEGA, Z, and the NIF

New designs and a new analysis technique have been developed for an existing compact charged-particle spectrometer on the NIF and OMEGA. The new analysis technique extends the capabilities of this diagnostic to measure arbitrarily shaped ion spectra down to 1 MeV with yields as low as 10 6 . Three different designs are provided optimized for the measurement of DD protons, T 3 He deuterons, and 3 He 3 He protons. The designs are highly customizable, and a generalized framework is provided for optimizing the design for alternative applications. Additionally, the understanding of the detector’s response and uncertainties is greatly expanded upon. A new calibration procedure is also developed to increase the precision of the measurements.

47 OTHER INSTRUMENTATION↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

Pearcy, J.↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

47 OTHER INSTRUMENTATION↗

Developing “inverted-corona” fusion targets as high-fluence neutron sources

We present experimental studies of inverted-corona targets as neutron sources at the OMEGA Laser Facility and the National Ignition Facility (NIF). Laser beams are directed onto the inner walls of a capsule via laser-entrance holes (LEHs), heating the target interior to fusion conditions. The fusion fuel is provided either as a wall liner, e.g., deuterated plastic (CD), or as a gas fill, e.g., D 2 gas. Such targets are robust to low-mode drive asymmetries, allowing for single-sided laser drive. On OMEGA, 1.8-mm-diameter targets with either a 10-μm CD liner or up to 2 atm of D 2 -gas fill were driven with up to 18 kJ of laser energy in a 1-ns square pulse. Neutron yields of up to 1.5 × 1010 generally followed expected trends with fill pressure or laser energy, although the data imply some mix of the CH wall into the fusion fuel for either design. Comparable performance was observed with single-sided (1x LEH) or double-sided (2x LEH) drive. NIF experiments tested the platform at scaled up dimensions and energies, combining a 15-μm CD liner and a 3-atm D2-gas fill in a 4.5-mm diameter target, laser-driven with up to 330 kJ. Neutron yields up to 2.6 × 10 12 were measured, exceeding the scaled yield expectation from the OMEGA data. The observed energy scaling on the NIF implies that the neutron production is gas dominated, suggesting a performance boost from using deuterium–tritium (DT) gas. In this work, we estimate that neutron yields exceeding 10 14 should be readily achievable using a modest laser drive of ~300 kJ with a DT fill.

47 OTHER INSTRUMENTATION↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Symmetry tuning and high energy coupling for an Al capsule in a Au rugby hohlraum on NIF

Experiments on imploding an Al capsule in a Au rugby hohlraum with up to a 1.5 MJ laser drive were performed on the National Ignition Facility (NIF). The capsule diameter was 3.0 mm with ∼1 MJ drive and 3.4 mm with ∼1.5 MJ drive. Effective symmetry tuning by modifying the rugby hohlraum shape was demonstrated, and good shell symmetry was achieved for 3.4 mm capsules at a convergence of ∼10. The nuclear bang time and the shell velocity from simulations agree with experimental data, indicating ∼500 kJ coupling with 1.5 MJ drive or ∼30% efficiency. The peak velocity reached above 300 km/s for a 120 μm-thick Al capsule. The laser backscatter inside the low-gas-filled rugby hohlraum was very low (<4%) at both scales. The high energy coupling allows implosion designs with increased adiabat, which, in turn, increases the tolerance to detrimental effects of instabilities and asymmetries. These encouraging experimental results open new opportunities for both the mainline single-shell scheme and the double-shell design toward ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Saturn-ring proton backlighters for the National Ignition Facility

Proton radiography is a well-established technique for measuring electromagnetic fields in high-energy-density plasmas. Fusion reactions producing monoenergetic particles, such as D 3 He, are commonly used as a source, produced by a capsule implosion. Using smaller capsules for radiography applications is advantageous as the source size decreases, but on the National Ignition Facility (NIF), this can introduce complications from increasing blow-by light, since the phase plate focal spot size is much larger than the capsules. In this article, we report a demonstration of backlighter targets where a “Saturn” ring is placed around the capsule to block this light. The nuclear performance of the backlighters is unperturbed by the addition of a ring. We also test a ring with an equatorial cutout, which severely affects the proton emission and is not viable for radiography applications. These results demonstrate the general viability of Saturn ring backlighter targets for use on the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗