Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE) – Physical Workload Approximation

The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA Johnson Space Center (JSC) is developing a hybrid reality exploration surface analog, “Assessments of Physiology and Cognition in Hybrid-reality Environments” (APACHE). The goal of APACHE is to create a planetary extravehicular activity (EVA) simulation environment that provides a representative physical and cognitive workload approximation using a combination of virtual reality (VR), physical reality, and hybrid reality (HR) techniques. To develop and characterize the physical workload approximation within the APACHE environment, a two-part approach was implemented. In part 1, baseline physical work load during ambulation within APACHE was evaluated and compared with that in other planetary EVA analog environments and with existing data sets from Apollo planetary EVAs and reduced gravity testing of prototype planetary spacesuits. For this evaluation, 10 subjects were asked to ambulate in three surface analog environments: a passive treadmill in APACHE, natural terrain in an outdoor field environment, and a standard motorized treadmill. Subjects’ heart rate and metabolic rate (VO2/VCO2) were measured and compared among the different test conditions and existing data sets. Gait parameters were also collected to compare with suited mechanics and to understand the role of gait kinematics in physical workload. In part 2, the aim is to evaluate the addition of a custom weighted body suit to the aforementioned surface analog environments and the ability to titrate the suit configuration to provide the best possible physical workload approximation for simulation of lunar and Martian EVAs.

Alex Baughman↗

Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE) – Physical Workload Approximation

The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA Johnson Space Center (JSC) is developing a hybrid reality exploration surface analog, “Assessments of Physiology And Cognition in Hybrid-reality Environments” (APACHE). The goal of APACHE is to create a planetary extravehicular activity (EVA) simulation environment that provides a representative physical and cognitive workload approximation using a combination of virtual reality (VR), physical reality, and hybrid reality (HR) techniques. To develop and characterize the physical workload approximation within the APACHE environment, a two-part approach was implemented. In part 1, baseline physical workload during ambulation within APACHE was evaluated and compared with that in other planetary EVA analog environments and with existing data sets from Apollo planetary EVAs and reduced gravity testing of prototype planetary spacesuits. For this evaluation, 10 subjects were asked to ambulate in three surface analog environments: a passive treadmill in APACHE, natural terrain in an outdoor field environment, and a standard motorized treadmill. Subjects’ heart rate and metabolic rate (VO2/VCO2)were measured and compared among the different test conditions and existing data sets. Gait parameters were also collected to compare with suited mechanics and to understand the role of gait kinematics in physical workload. In part 2, the aim is to evaluate the addition of a custom weighted body suit to the aforementioned surface analog environments and the ability to titrate the suit configuration to provide the best possible physical workload approximation for simulation of lunar and Martian EVAs.

Alexander J Baughman↗

Validation of Decompression Sickness Risk Mitigation Protocols for Planetary Spaceflight Missions

BACKGROUND: Apollo missions used a 100% O2 cabin atmosphere which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activity (EVA) on the moon. NASA’s future missions to the moon and Mars are expected to use nitrox gas mixtures of up to 34% O2, 66% N2, which will reduce flammability risk compared with Apollo, but will necessitate Oxygen prebreathe prior to EVA to reduce DCS risk to acceptable levels. Prebreathe protocols used on the space shuttle and International Space Station are validated for microgravity EVAs, but the significantly increased risk of DCS during equivalent ambulatory EVAs make these protocols inapplicable to planetary EVA. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA as a compromise that balances prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. However, this atmosphere may not be used for vehicles that do not support frequent EVA, and with commercial providers and international providers expected to provide landers, pressurized rovers, habitats, and spacesuits, different combinations of vehicle and spacesuit atmospheres are possible and will each require validated prebreathe protocols. OVERVIEW: Key components of a multi-year strategic roadmap include: 1) Establish hypobaric chamber facility capable of supporting 8-person EVA prebreathe validation tests at saturation atmospheres up to 36% O2; 2) validate an EVA physical workload simulation for use during prebreathe validation testing; 3) validate the recommended “exploration atmosphere” prebreathe protocol; 4) validate prebreathe protocols for additional atmospheric combinations that bound the most likely potential operating ranges of future vehicles and spacesuits; and 5) update DCS risk estimation models based on results of prebreathe validation studies. DISCUSSION: Details and data from completion of the first two steps of the strategic roadmap will be presented; the third step is currently underway, with pilot results provided in a companion presentation. Steps four and five will require a multi-year series of chamber tests; collaborations are being pursued.

Andrew F. J. Abercromby↗

Results of a 3-day Pilot Study to Validate Planetary Prebreathe Protocols Using a 56.5 kPa 34% O2, 66% N2 Saturation Cabin Atmosphere

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies was initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 3-day human-in-the-loop system checkout. METHODS: Six volunteers acclimated to the 56.6kPa/34% O2 66% N2 environment for 48hrs prior to conducting a 20-minute prebreathe and a 6-hour simulated EVA at 34kPa/85% O2 / 15% N2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs. Decompression stress was evaluated by serial doppler and echocardiographs, as well as by clinical features of DCS signs/symptoms. RESULTS AND DISCUSSION: Preliminary data analysis noted venous gas emboli (VGE) in 3 of 6 subjects, with peak Grade II VGE by Doppler and peak E-B score of 5 by cardiac ultrasonography. No volunteers were diagnosed with DCS during this initial test. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Validation of exploration prebreathe protocols has since been initiated with an 11-day saturation test using the same facility and protocol.

Alejandro Garbino↗

Evaluation of Planetary Extravehicular Activity Prebreathe Protocols using a 56.5 kPa, 34% O2, 66% N2 Saturation Cabin Atmosphere in an 11-day Hypobaric Hypoxia Study

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during Lunar extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. A cabin/vehicle “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies were initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 11-day human-in-the-loop system checkout. METHODS: Six volunteers lived in a hyboparic chamber for 11 days with an ‘exploration atmosphere’ of 56.6kPa/34% O2 66% N2. Subjects acclimated to the exploration atmosphere for 48hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15min, as well as clinical monitoring for DCS signs/symptoms. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were present in 3 of 6 subjects during EVAs, with peak Grade II VGE as evaluated by Doppler and a peak Eftedal-Brubakk score of 5 by cardiac ultrasonography. Two cases of DCS were diagnosed during the 11-day test chamber. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Two cases of DCS (8%) does not cross either accept or reject pre-test criterion, so an additional study is planned for 2023 to meet our pre-test thresholds.

Alejandro Garbino↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗