Search NASASearch

Engineering topics

Kahn, Steven M.

Publications and source records attributed to Kahn, Steven M..

Reflection Grating Array Associated with the Reflection Grating Spectrometer Developed by the Space Research Organization of the Netherlands for the X-ray Multi-Mirror Mission (XMM)

The University of California, Berkeley (UCB) served as the Principal Investigator institution for the United States participation in the development of the Reflection Grating Spectrometer (RGS) which included the design, development, fabrication, and testing of the Reflection Grating Assembly (RGA). UCB was assisted in this role by the Lawrence Livermore National Laboratory and Columbia University who provided the primary facilities, materials, services and personnel necessary to complete the development. UC Berkeley's Dr. Steven Kahn provided the technical and scientific oversight for the design. development and testing of the RGA units by monitoring the performance of the units at various stages in their development. Dr. Kahn was also the primary contact with the Space Research Organization of the Netherlands (SRON) and represented the RGA development at all SRON and European Space Agency (ESA) reviews of the RGA status. In accordance with the contract, the team designed and developed novel optical technology to meet the unique requirements of the RGS. The ESA XMM-Newton Mission carries two identical Reflection Grating Spectrometers (RGS) behind two of its three nested sets of Wolter I type mirrors. The instrument allows high-resolution measurements in the soft X-ray range (6 to 38 angstroms or 2.1 to 0.3 keV) with a maximum effective area of about 140 sq cm at 15 angstroms. Its design is optimized for the detection of the K-shell transitions of carbon, nitrogen, oxygen, neon, magnesium, and silicon. as well as the L shell transitions of iron. The RGA itself consists of two units. A structure for each unit was designed to hold up to 220 gratings. In its final configuration, one unit holds 182 gratings and the second hold 181 gratings.

Kahn, Steven M.

Interstellar X-Ray Absorption Spectroscopy of the Crab Pulsar with the LETGS

We study the interstellar X-ray absorption along the line of sight to the Crab Pulsar. The Crab was observed with the Low Energy Transmission Grating Spectrometer on the Chandra X-ray Observatory, and the pulsar, a point source, produces a full resolution spectrum. The continuum spectrum appears smooth, and we compare its parameters with other measurements of the pulsar spectrum. The spectrum clearly shows absorption edges due to interstellar Ne, Fe, and O. The O edge shows spectral structure that is probably due to O bound in molecules or dust. We search for near-edge structure (EXAFS) in the O absorption spectrum. The Fe L absorption spectrum is largely due to a set of unresolved discrete n=2-3 transitions in neutral or near-neutral Fe, and we analyze it using a new set of dedicated atomic structure calculations, which provide absolute cross sections. In addition to being interesting in its own right, the ISM absorption needs to be understood in quantitative detail in order to derive spectroscopic constraints on possible soft thermal radiation from the pulsar.

Paerels, Frits

X-Ray Spectroscopic Laboratory Experiments In Support of the NASA X-Ray Astronomy Flight Program

During the 1997 performance period, our work focused on the L-shell X-ray emission from highly charged iron ions in the 10-18 A region. Details of our accomplishments in 1997 are presented in the following. We start by describing the laboratory measurements made and their impact on the X-ray flight program and conclude by an overview of new instrumental capabilities developed for uses in the coming year.

Kahn, Steven M.

X-Ray Spectroscopic Laboratory Experiments in Support of the X-Ray Astronomy Program

Our program is to perform a series of laboratory investigations designed to resolved significant atomic physics uncertainties that limit the interpretation of cosmic X-ray spectra. Specific goals include a quantitative characterization of Fe L-shell spectra; the development of new techniques to simulate Maxwellian plasmas using an Electron Beam Ion Trap (EBIT); and the measurement of dielectronic recombination rates for photoionized gas. New atomic calculations have also been carried out in parallel with the laboratory investigations.

Kahn, Steven M.

The X-Ray Spectrum of the Supernova Remnant 1E 0102-72.3

In this letter we present the soft X-ray (5-35A) spectrum of the supernova remnant (SNR) IE 0102-72.3 in the Small Magellanic Cloud, acquired by the reflection grating spectrometer (RGS) aboard ESA's XMM-Newton Observatory. This extended-source X-ray spectrum of unprecedented spectral resolution (lambda/Delta(lambda) approx. 300) permits, for the first time, unabiguous identification and measurement of isolated emission lines and line complexes alike. The diagnostic power of performing spectroscopy using groups of emission lines from single ions is exemplified. In particular, the bright Lyman and helium series lines for light elements (C VI, O VII, O VIII, Ne IX, Ne X and possibly Mg XI & Mg XII) show peculiar ratios, where the values [1s - np] / [1s - (n + l)p] are systematically weaker than expected for electron impact excitation. These measured ratios resemble signatures of recombining or charge exchanging plasmas. We argue that charge exchange, given its large cross section and evidence for inhomogeneous media within the SNR, is a likely mechanism for the observed emission. Also. the well known temperature diagnostics G(T(sub e)) = (i + f)/r of helium- like triplets (O VII & Ne IX) indicate high temperatures, well above the maximum emission temperature T(sub m) for each ion, and consistent with a purely ionizing plasma. The density diagnostics R(n(sub e)) = f / i meanwhile, are consistent with the low density limit, as expected.

Rasmussen, Andrew P.

Extreme ultraviolet spectroscopy of PKS 2155-304

We present the extreme ultraviolet (75-110 A) spectrum of the BL Lac object PKS 2155-304, the first spectrum of an extragalactic source obtained with the Extreme Ultraviolet Explorer (EUVE). The spectrum shows a generally smooth continuum, which can be modeled by a single power law plus interstellar absorption, and possibly an absorption feature at approximately 80 A. The best fit to the data suggests that the EUV spectrum can be interpreted as a simple extrapolation of the X-ray continuum, with an energy index alpha is approximately = 1.6; however, shallower or steeper power laws with indices between -0.4 and 2.7 cannot be ruled out by the existing EUV data alone. The data provide strong constraints on the interstellar neutral H and He along the line of sight. Using a column density of 1.36 x 10(exp 20)/sq cm for the Galactic neutral hydrogen along the PKS 2155-304 line of sight, the neutral helium column density is constrained to be 9%-10% of the hydrogen amount.

Fruscione, Antonella

X-ray emission-line spectra of photoionized plasmas - Density sensitivity of the Fe L-shell series

The circumsource environments of accretion-powered X-ray sources are likely to support relatively dense (greater than 10 exp 11/cu cm) photoionized X-ray emission-line regions. The Fe L-shell ions provide a versatile class of plasma diagnostics in this regime, their multielectron structures resulting in diverse spectral phenomena. Attention is given to the spectral response of Fe L-shell ions to variations in electron density over the range 10 exp 11 to 10 exp 16/cu cm. It is found that density-sensitive line ratios exist in the wavelength interval 12-17 A for the ions Fe XVII-XXI. The prominent role of radiative recombination in the population kinetics distinguishes the density-sensitive Fe lines in photoionized plasmas from those which operate in coronal equilibrium plasmas. The results of detailed atomic modeling of these ions are presented and applications to spectroscopic observations of accretion-driven X-ray sources are discussed.

Liedahl, Duane A.

Bowen fluorescence in AM Herculis stars

The study relates the observations of the Bowen fluorescence lines in AM Her and EF Eri, two AM Her systems. The implications of source variability and the checks performed in order to verify the accuracy of the data are reviewed. The line ratios for H I and He II are shown to deviate considerably from those expected; in this light, the H I and He II emission in AM Her is analyzed in detail. This approach makes it possible to put limits on line and continuum optical depths as well as temperatures. These limits along with the observed Bowen emission are used to construct a picture of the emission-line regions in the two sources, producing the values for the size, density, and temperature of a region. The derived value of the size is found to be significantly less than the size of the Roche lobe of the white dwarf, while the large range of densities is attributed to the exponential temperature dependence in the expression used for density.

Schachter, Jonathan

X-ray spectral signatures of photoionized plasmas

Plasma emission codes have become a standard tool for the analysis of spectroscopic data from cosmic X-ray sources. However, the assumption of collisional equilibrium, typically invoked in these codes, renders them inapplicable to many important astrophysical situations, particularly those involving X-ray photoionized nebulae. This point is illustrated by comparing model spectra which have been calculated under conditions appropriate to both coronal plasmas and X-ray photoionized plasmas. It is shown that the (3s-2p)/(3d-2p) line ratios in the Fe L-shell spectrum can be used to effectively discriminate between these two cases. This diagnostic will be especially useful for data analysis associated with AXAF and XMM, which will carry spectroscopic instrumentation with sufficient sensitivity and resolution to identify X-ray photoionized nebulae in a wide range of astrophysical environments.

Liedahl, Duane A.

X-ray spectroscopic instrumentation for the 21st century

Several technologies being developed for high resolution X-ray spectroscopy are compared to determine the most suitable applications for each. Nondispersive cryogenic technology is considered by means of devices such as microcalorimeters and superconducting tunnel-junction detectors, and dispersive technologies are represented by crystal diffractors, transmission gratings and reflection gratings. Calorimeters and superconducting tunnel-junction conductors are found to be suitable for high energies while reflection gratings are more effective at lower energies. In general, however, the selected technology depends primarily on the particular implementation. Parameters such as launch capability, constraints, and scientific drivers are the guiding forces for selecting a particular device.

Kahn, Steven M.

Performance optimization for hard X-ray/soft gamma-ray detectors

This paper discusses the optimization of the performance of imaging scintillation detectors used in the hard X-ray/soft gamma-ray (20-300) keV region of the spectrum. In these devices, absorption of an incident gamma-ray within an alkali halide crystal induces a scintillation light distribution which is centroided by an imaging photomultiplier tube mounted to the crystal. The ultimate imaging resolution is strongly affected by the detailed propagation of the scintillation light within the crystal and at the interface between the crystal and the phototube face plate. A number of refined techniques for preparing the scintillation crystals so as to optimize the imaging resolution have been investigated. The results indicate very good agreement with relatively simple models of the light propagation. It is shown that it is possible to achieve resolution consistent with the most optimistic models.

Harrison, Fiona A.

A reflection grating spectrometer for the X-ray Multi-Mirror (XMM) space observatory - Design and calculated performance

Attention is given to a spectrometer design candidate for the X-ray Multi-Mirror observatory, being planned by the European Space Agency as a long-lived large-area array of telescopes. The science requirement of moderate resolution spectroscopy in a two octave region with extremely high throughput leads to the use of grazing incidence reflection gratings. It is noted that the sensitivity of the instrument is sufficient to permit the first spectral detection of soft X-ray features in external galaxies.

Hettrick, Michael C.