Search NASA⌕ Search

Engineering topics

Kaita, Ed

Publications and source records attributed to Kaita, Ed.

Advanced Land Imager Assessment System

The Advanced Land Imager Assessment System (ALIAS) supports radiometric and geometric image processing for the Advanced Land Imager (ALI) instrument onboard NASA s Earth Observing-1 (EO-1) satellite. ALIAS consists of two processing subsystems for radiometric and geometric processing of the ALI s multispectral imagery. The radiometric processing subsystem characterizes and corrects, where possible, radiometric qualities including: coherent, impulse; and random noise; signal-to-noise ratios (SNRs); detector operability; gain; bias; saturation levels; striping and banding; and the stability of detector performance. The geometric processing subsystem and analysis capabilities support sensor alignment calibrations, sensor chip assembly (SCA)-to-SCA alignments and band-to-band alignment; and perform geodetic accuracy assessments, modulation transfer function (MTF) characterizations, and image-to-image characterizations. ALIAS also characterizes and corrects band-toband registration, and performs systematic precision and terrain correction of ALI images. This system can geometrically correct, and automatically mosaic, the SCA image strips into a seamless, map-projected image. This system provides a large database, which enables bulk trending for all ALI image data and significant instrument telemetry. Bulk trending consists of two functions: Housekeeping Processing and Bulk Radiometric Processing. The Housekeeping function pulls telemetry and temperature information from the instrument housekeeping files and writes this information to a database for trending. The Bulk Radiometric Processing function writes statistical information from the dark data acquired before and after the Earth imagery and the lamp data to the database for trending. This allows for multi-scene statistical analyses.

Chander, Gyanesh↗

Landsat-7 ETM+ On-Orbit Reflective-Band Radiometric Stability and Absolute Calibration

The Landsat-7 spacecraft carries the Enhanced Thematic Mapper Plus (ETM+) instrument. This instrument images the Earth land surface in eight parts of the electromagnetic spectrum, termed spectral bands. These spectral images are used to monitor changes in the land surface, so a consistent relationship, i.e., calibration, between the image data and the Earth surface brightness, is required. The ETM+ has several on- board calibration devices that are used to monitor this calibration. The best on-board calibration source employs a flat white painted reference panel and has indicated changes of between 0.5% to 2% per year in the ETM+ response, depending on the spectral band. However, most of these changes are believed to be caused by changes in the reference panel, as opposed to changes in the instrument's sensitivity. This belief is based partially on on-orbit calibrations using instrumented ground sites and observations of "invariant sites", hyper-arid sites of the Sahara and Arabia. Changes determined from these data sets indicate are 0.1% - 0.6% per year. Tests and comparisons to other sensors also indicate that the uncertainty of the calibration is at the 5% level.

FROM↗

Landsat-7 ETM+ On-Orbit Radiometric Calibration

As of July, 2000 the Enhanced Thematic Mapper Plus (ETM+) sensor on Landsat-7 has been operating on-orbit for about 15 months. The ETM+ images the Earth in has eight spectral bands in the visible, near-infrared (IR), short wavelength infrared (SWIR), and thermal portions of the spectrum. Three on-board calibration systems are available for the reflective bands: (1) the Internal Calibrator (IC), (2) the Partial Aperture Solar Calibrator (PASC), and (3) the Full Aperture Solar Calibrator (FASC). The Internal Calibrator also provides the thermal band calibration. Several investigators on the Landsat science team are also regularly performing vicarious calibrations. The internal calibrator, which during much of the pre-launch testing and early on-orbit check out period, showed up to 15% variability with time, has since stabilized as the instrument has assumed a regular schedule of operations and is now typically showing only a few percent variation with time, mostly associated with warm-up. The PASC has been the most variable of the sources: the response to the PASC has increased by as much as 50% is some bands and is oscillating with time, perhaps due to contamination. The FASC has been the most stable of the sources: mid scan response to the FASC diffuser have varied from -4%/yr for band 4 (0.83 microns) to -2%/yr for band 1 (0.49 microns) to +1%/yr for band 7 (2.2 microns). These decreases in response in bands 1-4 would have been about half as large if measured on the right (west) side of the panel and about twice as large if measured on the left side of the panel. The current interpretation is that the FASC diffuser panel is changing non-uniformly in its reflectance characteristics. Vicarious ground measurements have generally been consistent with the pre-launch measurements of the instrument responsivity and have not shown evidence of a change in responsivity with time. The FASC, IC, and vicarious results suggest the instrument has not changed by more than two percent in responsivity since launch and that the absolute calibration is good to the advertised five percent.

Markham, Brian L.↗