Search NASA⌕ Search

Engineering topics

Kaita, R

Publications and source records attributed to Kaita, R.

29 records · Page 2

Magnetic diagnostics for equilibrium reconstructions in the presence of nonaxisymmetric eddy current distributions in tokamaks (invited)

The lithium tokamak experiment (LTX) is a modest-sized spherical tokamak (R{sub 0}=0.4 m and a=0.26 m) designed to investigate the low-recycling lithium wall operating regime for magnetically confined plasmas. LTX will reach this regime through a lithium-coated shell internal to the vacuum vessel, conformal to the plasma last-closed-flux surface, and heated to 300-400 deg. C. This structure is highly conductive and not axisymmetric. The three-dimensional nature of the shell causes the eddy currents and magnetic fields to be three-dimensional as well. In order to analyze the plasma equilibrium in the presence of three-dimensional eddy currents, an extensive array of unique magnetic diagnostics has been implemented. Sensors are designed to survive high temperatures and incidental contact with lithium and provide data on toroidal asymmetries as well as full coverage of the poloidal cross-section. The magnetic array has been utilized to determine the effects of nonaxisymmetric eddy currents and to model the start-up phase of LTX. Measurements from the magnetic array, coupled with two-dimensional field component modeling, have allowed a suitable field null and initial plasma current to be produced. For full magnetic reconstructions, a three-dimensional electromagnetic model of the vacuum vessel and shell is under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Ka-band tunable direct-conversion correlation reflectometer for NSTX

The recent availability of broadband microwave quadrature mixers in the Ka-band (28-40 GHz) of frequencies has allowed the fabrication of low-cost direct-conversion detection circuits for use in the variable-frequency correlation reflectometer on the National Spherical Torus eXperiment (NSTX). The quadrature receiver in this case can be implemented as a simple homodyne circuit, without the complication of a single-sideband modulator or a feedforward tracking circuit present in more typical designs. A pair of direct-conversion receivers is coupled with broadband microwave voltage-controlled oscillators to construct a flexible dual-channel radar system with a fast frequency settling time of {approx}160 {mu}s. A detailed description of the design and a full characterization of the hardware are provided. Examples of turbulence measurements from radial and poloidal correlation reflectometry on NSTX using a poloidal array of antennas (oriented normal to the magnetic flux surfaces for conventional reflectometry) are presented.

43 PARTICLE ACCELERATORS↗

Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX

A dense array of 99 Langmuir probes has been installed in the lower divertor region of the National Spherical Torus Experiment (NSTX). This array is instrumented with a system of electronics that allows flexibility in the choice of probes to bias as well as the type of measurement (including standard swept, single probe, triple probe, and operation as passive floating potential and scrape-off-layer SOL current monitors). The use of flush-mounted probes requires careful interpretation. The time dependent nature of the SOL makes swept-probe traces difficult to interpret. To overcome these challenges, the single- and triple-Langmuir probe signals are used in complementary fashion to determine the temperature and density at the probe location. A comparison to midplane measurements is made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed digital holography for density and fluctuation measurements (invited)

The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system. At wave frequencies which are much greater than the plasma frequency, the plasma index of refraction is linearly proportional to the electron density and wavelength, and the measurement of the phase of a wavefront passing through the plasma gives the chord-integrated density directly for all points measured on the wavefront. High-speed infrared cameras (up to {approx}40 000 fps at {approx}64x4 pixels) with resolutions up to 640x512 pixels suitable for use with a CO{sub 2} laser are readily available, if expensive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions

A high density Langmuir probe array has been developed for measurements of scrape-off layer parameters in NSTX. Relevant scale lengths for heat and particle fluxes are 1-5 cm. Transient edge plasma events can occur on a time scale of several milliseconds, and the duration of a typical plasma discharge is {approx}1 s. The array consists of 99 individual electrodes arranged in three parallel radial rows to allow both swept and triple-probe operation and is mounted in a carbon tile located in the lower outer divertor of NSTX between two segments of the newly installed liquid lithium divertor. Initial swept probe results tracking the outer strike point through probe flux measurements are presented.

36 MATERIALS SCIENCE↗

Use of the Far Infrared Tangential Interferometer/Polarimeter diagnostic for the study of rf driven plasma waves on NSTX

A rf detection system for waves in the 30 MHz range has been constructed for the Far Infrared Tangential Interferometer/Polarimeter on National Spherical Torus Experiment (NSTX). It is aimed at monitoring high frequency density fluctuations driven by 30 MHz high harmonic fast wave fields. The levels of density fluctuations at various radial chords and antenna phase angles can be estimated using the electric field calculated by TORIC code and linearized continuity equation for the electron density. In this paper, the experimental arrangement for the detection of rf signal and preliminary results of simulation will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopic Motion of Liquid Metal Plasma Facing Components In A Diverted Plasma

Liquid metal plasma facing components (PFCs) have been identified as an alternative material for fusion plasma experiments. The use of a liquid conductor where significant magnetic fields are present is considered risky, with the possibility of macroscopic fluid motion and possible ejection into the plasma core. Analysis is carried out on thermoelectric magnetohydrodynamic (TEMHD) forces caused by temperature gradients in the liquid-container system itself in addition to scrape-off-layer currents interacting with the PFC from a diverted plasma. Capillary effects at the liquid-container interface will be examined which govern droplet ejection criteria. Stability of the interface is determined using linear stability methods. In addition to application to liquidmetal PFCs, thin film liquidmetal effects have application to current and future devices where off-normal events may liquefy portions of the first wall and other plasma facing components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗