MgB2 Coating Parameter Optimization Using a 1.3-GHz 1-Cell Cavity
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Kako, Eiji.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Highly efficient superconducting radio-frequency cavities exhibit low heat loss and are used as components in accelerators and superconducting devices due to their high Q-values. The precise location of magnetic flux trapping in cavities is necessary to identify its effects on the performance of superconducting cavities. In this study, we report a new combined mapping system to measure the temperature and magnetic field on the equator. The proposed system comprehensively maps local magnetic field changes as magnetic flux trapping due to quenching. Our experimental results show that magnetic flux trapping due to quenching increases the local surface resistance of superconducting cavities at 2 K. Thus, the proposed system elucidates the relationship between local flux trapping due to quenching and surface resistance in superconducting cavities and highlights the effect of quenching on the surface resistance. This system can aid in the development of superconducting cavities with higher Q values.
Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.
In 2020, the TTC (TESLA Technology Collaboration) celebrates 30 years of collaborative efforts on SRF technologies. The first international TESLA workshop on a TeV Energy Superconducting Linear Accelerator was held at Cornell University on July 23-26, 1990. The purpose of the meeting was to work on a parameter list for a superconducting high energy physics collider in the Teravolt energy region and to explore ideas on how to increase the gradients and lower the costs for the accelerator structures. It was clear from the beginning that the needed technological progress would require a large international collaboration. This meeting was indeed the origin of a long preparation effort toward a future ILC (International Linear Collider), which eventually led to the realization of the TTF (TESLA Test Facility, since 2005 operated as the DESY user facility FLASH) and the European XFEL also at DESY, and created the conditions supporting the proposals for several large SRF-based research facilities like SNS, LCLS-II, ESS, PIP-II and SHINE, as well as a growing number of smaller facilities around the world. Highlights of this 30-year international collaboration are presented and celebrated.
Superconducting radio frequency (SRF) cavities made from niobium and cooled with liquid helium are becoming key components of many particle accelerators. The helium vessels surrounding the RF cavities, portions of the niobium cavities themselves, and also possibly the vacuum vessels containing these assemblies, generally fall under the scope of local and national pressure vessel codes. In the U.S., Department of Energy rules require national laboratories to follow national consensus pressure vessel standards or to show ''a level of safety greater than or equal to'' that of the applicable standard. Thus, while used for its superconducting properties, niobium ends up being treated as a low-temperature pressure vessel material. Niobium material is not a code listed material and therefore requires the designer to understand the mechanical properties for material used in each pressure vessel fabrication; compliance with pressure vessel codes therefore becomes a problem. This report summarizes the approaches that various institutions have taken in order to bring superconducting RF cryomodules into compliance with pressure vessel codes. In Japan, Germany, and the U.S., institutions building superconducting RF cavities integrated in helium vessels or procuring them from vendors have had to deal with pressure vessel requirements being applied to SRF vessels, including the niobium and niobium-titanium components of the vessels. While niobium is not an approved pressure vessel material, data from tests of material samples provide information to set allowable stresses. By means of procedures which include adherence to code welding procedures, maintaining material and fabrication records, and detailed analyses of peak stresses in the vessels, or treatment of the vacuum vessel as the pressure boundary, research laboratories around the world have found methods to demonstrate and document a level of safety equivalent to the applicable pressure vessel codes.