Effect of Lateral Conduction in a Rectangular Fuel Plate and Optimum Stripe Widths for the OPAL Reactor

The impetus for this work is the Proliferation Resistance Optimization (PRO-X) program, which was created by the National Nuclear Security Administration (NNSA) of the US Department of Energy (DOE) to provide a framework for developing reactor designs that minimize the production of special nuclear materials while maximizing performance for peaceful uses. The Argentine company INVAP and Argonne National Laboratory collaborated to share knowledge and expertise regarding the thermal analysis of research reactors. Working together, they designed a series of test problems based on the Open Pool Australian Light Water (OPAL) reactor, whose fuel is in the form of flat plates cooled by water flowing through narrow rectangular channels. ANL used their PLTEMP/ANL code. INVAP used their TERMIC code (and its new multi-plate version, TERMIC-MP). Then, INVAP and ANL compared the two sets of results. 1-D models were used during the collaboration since for research reactor analysis, largely 1-D thermal-hydraulics models are commonly used because they are simple to apply and technically defendable. The collaboration between the two organizations aims for improvements in thermal-hydraulic models. Improvements to methods and models can reduce modeling uncertainties and excessive conservatism, allowing greater reactor performance without reducing predicted safety margins. Therefore, these improvements potentially expand the design space, making additional designs feasible, which, in turn, may achieve better fuel utilization and proliferation resistance in the designs. This report provides justification for the lateral node size (stripe width) chosen for the 1-D computer models during the collaboration. The lateral heat conduction in OPAL fuel plates is evaluated using the two-dimensional conduction capability of PLTEMP/ANL to determine a representative hot-stripe width that can be conservatively used for one-dimensional steady-state thermal-hydraulic analysis. Basically, a representative hot-stripe width needs to be selected so that the actual heat flux averaged over this stripe width is greater than or equal to the maximum heat flux obtained by the two-dimensional analysis. Detailed results in this report show that a hot-stripe width of 8.125 mm can be conservatively used for the one-dimensional thermal-hydraulics analysis of all plates. Therefore, eight equal stripes (8.125 mm each) are recommended to be modeled in the MCNP and PLTEMP/ANL full core models of the OPAL reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of many reactors both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors, Volume 1

This is Volume 1 of a two-volume document that collects the verification and validation (V&V) works done for the PLTEMP/ANL code during the years of its development and improvement. Volume 1 describes the V&V of sixteen capabilities of the PLTEMP/ANL code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis. Volume 2 describes the V&V of developments and improvements since the release of PLTEMP/ANL Version 4.3. Each chapter of the document focuses on verifying or validating a specific part of the software that calculates a specific phenomenon, e.g., channel flow calculation, coolant property calculation, heat transfer calculation, and flow instability calculation. Software verification is performed by comparing the code with hand calculation, Microsoft spreadsheet calculation, Mathematica calculation, or MATLAB calculation. The software validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL V&V works that are available in the open literature are simply cited in Volume 1 of the document. PLTEMP/ANL has been used in the safety analysis reports of several US and foreign research reactors licensed and converted from highly enriched uranium fuel to low-enriched uranium fuel. A list of such reactors is given in Volume 1 of the document.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors, Volume 2

This is Volume 2 of a two-volume document that collects the verification and validation (V&V) works done for the PLTEMP/ANL code during the years of its development and improvement. Volume 1 describes the V&V of sixteen capabilities of the PLTEMP/ANL code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis. Volume 2 describes the V&V of developments and improvements since the release of PLTEMP/ANL Version 4.3. Each chapter of the document focuses on verifying or validating a specific part of the software that calculates a particular phenomenon, e.g., channel flow calculation, coolant property calculation, heat transfer calculation, and flow instability calculation. Software verification is performed by comparing the code with a hand calculation, Microsoft spreadsheet calculation, Mathematica calculation, or MATLAB calculation. The software validation is achieved by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL V&V works that are available in the open literature are simply referenced in Volume 1 of the document. PLTEMP/ANL has been used in safety analysis reports of several US and foreign research reactors licensed and converted from highly enriched uranium fuel to low-enriched uranium fuel. A list of such reactors is given in Volume 1 of the document.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.4 is a program that obtains a steady-state flow and temperature solution, in geometrical extent, for a nuclear reactor core, or a single fuel assembly, including the effect of manufacturing and modelling uncertainties by the means of hot channel factors. It is based on an evolutionary sequence of codes originally used for calculating plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over the past 30 years. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset of nucleate boiling ratio (ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability for select design and safety parameters is available to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors (Code Version 4.3)

The document compiles in a single volume the verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. The verification of sixteen capabilities of the PLTEMP/ANL Version 4.3 code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis are described and documented. Each chapter of the document deals with the verification or validation of a specific part of the software that calculates a specific phenomenon, e.g., channel flow calculation, coolant property calculation, heat transfer calculation, and flow instability calculation. The software verification work is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The software validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL verification works that are available in the open literature are simply referenced and not included in the document. PLTEMP/ANL has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User’s Guide to the PLTEMP/ANL Code (V.4.3)

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It should be noted that for a 3-dimensional solution the axial power shape is modeled without accounting for axial heat conduction. It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification and Validation of PARET/ANL (V.7.6)

This report documents the software testing which has been performed for the PARET/ANL version 7.6 software. The capabilities addressed in this testing were selected based on the use of the software for analysis work under the Research and Test Reactors Department quality assurance program. The verification and validation have been performed and documented to address the steady-state capabilities of the software, as described in Chapter 2, and the transient capabilities, as described in Chapter 3. Testing based on the comparison between PARET/ANL calculations and analytical solutions, hand calculations, or another code calculations of the test cases confirms that all the identified capabilities of the software were implemented correctly.

97 MATHEMATICS AND COMPUTING↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

The document compiles in a single volume the verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. The verification of sixteen capabilities of the PLTEMP/ANL Version 4.3 code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis are described and documented. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL verification works that are available in the open literature are simply referenced and not included in the document. PLTEMP/ANL has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fuel Plate Surface Temperature in a Fully-Uncovered Fuel Assembly after a Loss-of-Coolant Accident in an MTR-Type Research Reactor

A methodology and model that were developed in the 1960s for calculating the peak fuel temperature in an MTR fuel assembly in a reactor core that has been fully-uncovered in a hypothetical loss-of-coolant accident (LOCA) are revived and updated in this report. The semi-empirical one-node model is based on experiments on fuel elements for the Oak Ridge Research Reactor (ORR) and the Low Intensity Testing Reactor (LITR) that were done in the 1950s and 1960s at the Oak Ridge National Laboratory. The peak plate temperature in 18 LOCA tests in the ORR and two of 24 tests in the LITR, calculated using the model, are compared with experiments. The original model was used in LOCA analyses for the Omega West Reactor (OWR) at Los Alamos National Laboratory with HEU fuel and for three cores of the University of Virginia Reactor (UVAR) with both HEU and LEU fuels. The LOCA analyses for UVAR using this model were accepted for licensing purposes by the US Nuclear Regulatory Commission for an assembly containing 12 HEU fuel plates in 1970, an assembly containing 18 HEU fuel plates in 1984, and an assembly containing 22 LEU silicide fuel plates in 1994. The analyses done for the OWR and UVAR are repeated here and compared with data in the original reports in order to establish the validity of the model revived in this report. The model is then used in a subsequent LOCA analysis for the HEU and LEU cores of the RPI MTR-type reactor in Portugal. It can also be applied to other MTR-type reactors with designs similar to the LITR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

This report documents the verification and validation (V&V) of the PLTEMP/ANL Version 4.3 code. A brief description of the code and its history are given in Section 1.1. Section 1.2 provides an overview of PLTEMP/ANL verification and validation work done to date. Section 1.3 lists some publications by other authors on PLTEMP/ANL verification and validation. Section 1.4 describes a UNIX script developed to routinely verify the code after a code modification. The V&V work documented in this report was performed over several years, as code development progressed. In each verification/validation testing discussion, the version of PLTEMP/ANL which was initially used for the V&V work is referenced, but all of the testing presented in this report is applicable to current release version 4.3 of the code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User Guide to PARET/ANL (Rev.2)

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PLTEMP/ANL Verification for Assemblies Having Five-Layer Fuel Tubes

PLTEMP/ANL v4.2 is a steady-state single-phase (light or heavy water) code used by ANL and by research laboratories in several countries since 1980 in the analysis of various research reactors whose cores contain assemblies made of multiple fuel plates or nested fuel tubes. This analysis is typically needed in the conversion of cores from highly-enriched uranium to low-enriched uranium. PLTEMP calculates temperature distribution and safety margins, i.e., onset of nucleate boiling ratio (ONBR), onset of Ledinegg flow instability ratio (OFIR), and critical heat flux ratio (CHFR). The analytical method in the code for calculating radial and axial temperature distributions in fuel assemblies having multiple nested coaxial fuel tubes was recently extended and verified to allow each tube to have five layers instead of three. The method also works for fuel assemblies having flat fuel plates by setting the radii of curvature of plates to large values ({approx}50 m). The method models heat sources in all five layers and in the coolant channels. To verify the extended method, an Excel spreadsheet was developed using an alternative solution method to calculate the temperature distribution in a reactor of two fuel assemblies, each made of two five-layer flat fuel plates. The code and the spreadsheet solution methods are described and their solutions are compared.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.2 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.