Search NASA⌕ Search

Engineering topics

Kalita, P.

Publications and source records attributed to Kalita, P..

A compact x-ray diffraction system for dynamic compression experiments on pulsed-power generators

Pulsed-power generators can produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies using the magnetic loading technique. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength–strain rate dependence, structural phase transitions, and density of crystal defects, such as dislocations. Here, we present a cost-effective, compact, pulsed x-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically driven ramp compression of materials with a single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials’ community to investigate in situ dynamic phase transitions critical to equation of states. Finally, we present results using this new diagnostic to evaluate lattice compression in Zr and Al and to capture signatures of phase transitions in CdS.

47 OTHER INSTRUMENTATION↗

The Principal Hugoniot of Iron-Bearing Olivine to 1465 GPa

Shock compression experiments on natural compositions are imperative to accurately model planetary accretion and the interior dynamics of planets. Combining shock compression experiments from the Sandia Z Machine and the OMEGA EP laser facility with density functional theory-based molecular dynamics calculations, we report the first pressure-density-temperature (P-ρ-T) relationship of natural iron (Fe)-bearing olivine ((Mg 0.91 Fe 0.09 ) 2 SiO 4 ) on the principal Hugoniot between 166 and 1,465 GPa. Additionally, we report the first reflectivities of natural olivine liquid in this pressure range. Compared to the magnesium-endmember forsterite (Mg 2 SiO 4 ), the presence of Fe in typical mantle abundance (~9 wt% FeO) alters the U S -u P relation of olivine. Furthermore, the shock temperature and reflectivity of olivine are indistinguishable from forsterite where experimental conditions overlap. Both forsterite and olivine increase in reflectivity (and hence optical conductivity) with increasing temperature, with a maximum reflectivity of ~31% at shock velocities greater than 22 km/s (~800 GPa).

58 GEOSCIENCES↗

A spherical crystal diffraction imager for Sandia’s Z Pulsed Power Facility

Sandia’s Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigating fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Material Property (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect a diffraction signal close to the Z-DMP load and to recover the data. We have developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn–He α x rays to probe a shock-compressed material on the Z-DMP load. Finally, a spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x rays into a 1-in. thick tungsten housing, where an image plate is used to record the data.

47 OTHER INSTRUMENTATION↗

Polycapillary x-ray lenses for single-shot, laser-driven powder diffraction

X-ray diffraction measurements to characterize phase transitions of dynamically compressed, high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet (ZBL) long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.

47 OTHER INSTRUMENTATION↗