Search NASA⌕ Search

Engineering topics

Kaneko, M.

Publications and source records attributed to Kaneko, M..

Constraining nucleon effective masses with flow and stopping observables from the S π RIT experiment

Properties of the nuclear equation of state (EoS) can be probed by measuring the dynamical properties of nucleus-nucleus collisions. In this study, we present the directed flow (υ 1 ), elliptic flow (υ 2 ) and stopping (VarXZ) measured in fixed target Sn + Sn collisions at 270 AMeV with the SπRIT Time Projection Chamber. We perform Bayesian analyses in which EoS parameters are varied simultaneously within the Improved Quantum Molecular Dynamics-Skyrme (ImQMD-Sky) transport code to obtain a multivariate correlated constraint. The varied parameters include symmetry energy, S 0 , and slope of the symmetry energy, L, at saturation density, isoscalar effective mass, $m^{⁎}_{S}$/$m_{N}$ , isovector effective mass, $m^{⁎}_{υ}$/$m_{N}$ and the in-medium cross-section enhancement factor η. We find that the flow and VarXZ observables are sensitive to the splitting of proton and neutron effective masses and the in-medium cross-section. Comparisons of ImQMD-Sky predictions to the SπRIT data suggest a narrow range of preferred values for $m^{⁎}_{S}$/$m_{N}$, $m^{⁎}_{υ}$/$m_{N}$ and η.

Astronomy & Astrophysics↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapidity distributions of Z = 1 isotopes and the nuclear symmetry energy from Sn+Sn collisions with radioactive beams at 270 MeV/nucleon

The rapidity distributions of hydrogen isotopes emitted from central collisions of neutron-rich 132 Sn+ 124 Sn and neutron-deficient 108 Sn+ 112 Sn systems at 270 MeV/nucleon were investigated at RIKEN-RIBF. The data are compared with antisymmetrized molecular dynamics (AMD) calculations and the rapidity distributions can be reproduced after adjusting the in-medium nucleon-nucleon cross sections. The double ratios between the two reaction systems taken for the relative yields of deuteron to proton (d/p) and triton to proton (t/p) are further examined in the midrapidity domain, where the adjustments in the AMD calculations do not affect much on them. The d/p and t/p double ratios at midrapidity agree well with the ratio of the system neutron numbers and its squared value, respectively, and the rapidity dependence of these double ratios is consistent with a picture of partial mixing of colliding nuclei. By comparing with the AMD model which shows a strong symmetry energy dependence of the t/p double ratio, the experimental result in the midrapidity domain favors the calculation with a symmetry-energy slope parameter around L = 46 MeV rather than L = 108 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the Symmetry Energy with the Spectral Pion Ratio

Many neutron star (NS) properties, such as the proton fraction within a NS, reflect the symmetry energy contributions to the Equation of State that dominate when neutron and proton densities differ strongly. To constrain these contributions at supra-saturation densities, we measure the spectra of charged pions produced by colliding rare isotope tin (Sn) beams with isotopically enriched Sn targets. Here, using ratios of the charged pion spectra measured at high transverse momenta, we deduce the slope of the symmetry energy to be 42 < $L$ < 117 MeV. This value is slightly lower but consistent with the $L$ values deduced from a recent measurement of the neutron skin thickness of 208 Pb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Vuilleumier cycle cryocooler operating below 8 K

This paper describes the design and development of a Vuilleumier cycle cryocooler (VM cooler) operating below 8 K, for the application of small superconducting devices. Liquid nitrogen has been used as a heat sink of the hot displacer. The annular gap between the phenolic displacer and SUS 304 stainless cylinder has been used as a gap regenerator. In order to obtain the cooling temperature below 3 K, we designed a single stage VM cooler which is precooled to 10 K by another two stage VM cooler. The effect of the mean operating pressure, cycle speed and phase difference between the hot and cold displacer of each VM cooler will be also discussed, including the experimental results.

Matsubara, Y.↗

Compact Claude cycle refrigerator for laboratory use

A Claude cycle refrigerator with a three stage reciprocating expansion engine is described. Instead of a cam mechanism, valves are driven directly by magnetic solenoids operated by means of a micro processor control system. A swash plate mechanism is used to convert reciprocating motion of the expander pistons to rotary motion. A refrigeration capacity of 8 watts was achieved at 4.5 K with the operating pressure of 1.1 MPa and flow rate of 2.4 g/sec.. An effect of overintake operation was studied. Experimental results show that the efficiency of the expander has a peak point in the region of overintake operation with constant cycle speed, which agrees with theoretical results. The electrically controlled valve system is useful to vary the valve timing to achieve an optimum condition of operation.

Hiersaki, Y.↗

Muscle training and blood flow

Isotonic training effects on circulation for limb muscular strength characteristics, using peak blood flow and venous compliance measurements

Carlson, L. D.↗