Search NASA⌕ Search

Engineering topics

Kang, Bryan H.

Publications and source records attributed to Kang, Bryan H..

A Covariance Analysis Tool for Assessing Fundamental Limits of SIM Pointing Performance

This paper presents a performance analysis of the instrument pointing control system for NASA's Space Interferometer Mission (SIM). SIM has a complex pointing system that uses a fast steering mirror in combination with a multirate control architecture to blend feed forward information with feedback information. A pointing covariance analysis tool (PCAT) is developed specifically to analyze systems with such complexity. The development of PCAT as a mathematical tool for covariance analysis is outlined in the paper. PCAT is then applied to studying performance of SIM's science pointing system. The analysis reveals and clearly delineates a fundamental limit that exists for SIM pointing performance. The limit is especially stringent for dim star targets. Discussion of the nature of the performance limit is provided, and methods are suggested to potentially improve pointing performance.

pointing control↗

Spitzer Space Telescope: Focal Plane Survey Final Report: IRAC - Appendix B:

This final report summarizes the results and accuracies of the Spitzer Space Telescope focal plane survey. Accuracies achieved are compared to the focal plane survey calibration requirements put forth in the SIRTF IOC-SV Mission Plan [14] and pre-flight predictions made in [2]. The results of this focal plane survey are presently being used to support in-flight precision pointing, precision incremental offsets, IRS peakup array calibration, and ground pointing reconstruction...

kalman filtering↗

Spitzer Instrument Pointing Frame (IPF) Kalman Filter Algorithm

This paper discusses the Spitzer Instrument Pointing Frame (IPF) Kalman Filter algorithm. The IPF Kalman filter is a high-order square-root iterated linearized Kalman filter, which is parametrized for calibrating the Spitzer Space Telescope focal plane and aligning the science instrument arrays with respect to the telescope boresight. The most stringent calibration requirement specifies knowledge of certain instrument pointing frames to an accuracy of 0.1 arcseconds, per-axis, 1-sigma relative to the Telescope Pointing Frame. In order to achieve this level of accuracy, the filter carries 37 states to estimate desired parameters while also correcting for expected systematic errors due to: (1) optical distortions, (2) scanning mirror scale-factor and misalignment, (3) frame alignment variations due to thermomechanical distortion, and (4) gyro bias and bias-drift in all axes. The resulting estimated pointing frames and calibration parameters are essential for supporting on-board precision pointing capability, in addition to end-to-end 'pixels on the sky' ground pointing reconstruction efforts.

calibration↗

An Integrated Optimal Estimation Approach to Spitzer Space Telescope Focal Plane Survey

This paper discusses an accurate and efficient method for focal plane survey that was used for the Spitzer Space Telescope. The approach is based on using a high-order 37-state Instrument Pointing Frame (IPF) Kalman filter that combines both engineering parameters and science parameters into a single filter formulation. In this approach, engineering parameters such as pointing alignments, thermomechanical drift and gyro drifts are estimated along with science parameters such as plate scales and optical distortions. This integrated approach has many advantages compared to estimating the engineering and science parameters separately. The resulting focal plane survey approach is applicable to a diverse range of science instruments such as imaging cameras, spectroscopy slits, and scanning-type arrays alike. The paper will summarize results from applying the IPF Kalman Filter to calibrating the Spitzer Space Telescope focal plane, containing the MIPS, IRAC, and the IRS science Instrument arrays.

optimal estimations↗

SIRTF Focal Plane Survey: A Pre-flight Error Analysis

This report contains a pre-flight error analysis of the calibration accuracies expected from implementing the currently planned SIRTF focal plane survey strategy. The main purpose of this study is to verify that the planned strategy will meet focal plane survey calibration requirements (as put forth in the SIRTF IOC-SV Mission Plan [4]), and to quantify the actual accuracies expected. The error analysis was performed by running the Instrument Pointing Frame (IPF) Kalman filter on a complete set of simulated IOC-SV survey data, and studying the resulting propagated covariances. The main conclusion of this study is that the all focal plane calibration requirements can be met with the currently planned survey strategy. The associated margins range from 3 to 95 percent, and tend to be smallest for frames having a 0.14" requirement, and largest for frames having a more generous 0.28" (or larger) requirement. The smallest margin of 3 percent is associated with the IRAC 3.6 and 5.8 micron array centers (frames 068 and 069), and the largest margin of 95 percent is associated with the MIPS 160 micron array center (frame 087). For pointing purposes, the most critical calibrations are for the IRS Peakup sweet spots and short wavelength slit centers (frames 019, 023, 052, 028, 034). Results show that these frames are meeting their 0.14" requirements with an expected accuracy of approximately 0.1", which corresponds to a 28 percent margin.

pointing↗