Search NASA⌕ Search

Engineering topics

Kapat, Jayanta

Publications and source records attributed to Kapat, Jayanta.

At least 19 records

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

The Experimental and Numerical Investigation of Internal Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array and Single-Jet Impingement

Over the past decade, the drive to reduce greenhouse gas emissions and to increase thermal efficiency for turbomachinery has invigorated the application of supercritical carbon dioxide (sCO2) power cycles for energy generation. Compared to the industry standard air cycles, sCO2 applications hold the potential for several advantages, including higher efficiencies, smaller footprints, and zero greenhouse gas emissions. However, like any turbomachinery application, the turbine inlet temperature must increase to increase thermal efficiency. This introduces the need for internal cooling features to avoid material failure as operating conditions rise. Two standard features include pin fin turbulators in the trailing edge and jet impingement in the airfoil's leading edge. Over the past several decades, these features have been the subject of extensive research. However, the move to the sCO2 operating environment creates the need to re-visit these features to quantify the heat transfer capabilities within this supercritical cooling environment. The first objective of this paper is to discuss the development of the experimental demonstration for internal heat transfer testing at 200 bar and 400 Celsius, which sits well within the CO2 supercritical region. Next, the heat transfer for pin fin turbulators and single-jet impingement in the sCO2 environment is compared to existing air data-derived correlations to quantify any deviations from literature correlations. Finally, the experimental process aims to validate internal cooling conjugate heat transfer numerical simulations for sCO2 turbines.

20 FOSSIL-FUELED POWER PLANTS↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

An Experimental Investigation of Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array

Pin fin geometry in the trailing edge as turbulators in tur-bine blades has been a subject thoroughly researched for the past several decades. To improve the efficiency of turbomachinery, higher turbine inlet temperatures are necessary, introducing the need for internal cooling channel features, such as pin fin arrays. These solutions are necessary to avoid material failure at higher operating conditions by enhancing the heat transfer of the blade. Over the past decade, a shift toward applying supercritical carbon dioxide or sCO2 cycles has shown increased potential compared to the industry standard air cycles. Promising higher cycle ef¬ficiency, smaller footprints, and zero greenhouse gas emissions, sCO2 has become an attractive alternative to well-established air cycles. This alternative cycle introduces the need to re-visit the heat transfer capabilities of internal cooling geometries within this novel operating fluid environment. The first objective of this paper is to experimentally demonstrate the heat transfer charac-teristics of sCO2 as the secondary internal cooling fluid environ¬ment through testing a pin fin array in a closed loop at 200 bar and 400 Celsius inlet conditions, which stands well within the supercritical region of sCO2. Secondly, the experimental process aims to validate numerical simulation methodology for studying sCO2 environments for internal cooling of turbine blades in a matching pin fin geometry.

Wardell, Ryan J↗

Development of a 300 MWe Utility Scale Oxy-Fuel sCO2 Turbine

A 300 MWe direct-fired supercritical carbon dioxide (sCO2) oxy-fuel turbine is being developed that will burn natural gas-fired, coal syngas and even hydrogen mixtures capable of 1,150ºC turbine inlet temperature at 300 bar. This design will significantly improve the state-of-the-art for thermal efficiency and results in a high-pressure stream of CO2 with 98%+ carbon capture, making the power plant near emission-free and more efficient than Natural Gas Combined Cycle (NGCC) plants with carbon capture. This power plant will be capable of burning coal through gasification and cleanup of the synthesis gas (syngas). sCO2 power cycles are a transformational technology for the energy industry, providing higher efficiency heat source energy conversion for conventional and alternative energy sources. This novel cycle significantly reduces capital costs because of smaller equipment footprints, design modularity, and allows for rapid cyclic load and source following to balance solar and wind energy power swings. Oxy-fuel sCO2 cycles take these advantages even further, utilizing higher firing temperatures, improved efficiency, and simpler carbon capture strategies. This turbine will require cooled turbine nozzles and blades as well as advanced thermal management systems to accommodate these high temperatures. The cooled blade heat transfer correlations required new test programs at higher Reynolds number than air-breathing gas turbines for impingement, serpentine, and pin-fin regions. Novel blade optimization was performed to maximize aerodynamic efficiency, while minimizing cooling flows. A turbine layout was generated utilizing individual combustor cans with cooled liners feeding into a 6-stage axial flow turbine with cooled stator nozzles and turbine blades. The case design and thermal management preliminary design will be described.

Moore, Jeffrey↗

Neutron Characterization of 3D Printed Gas Turbine Alloy With Internal Cooling Structure

The objective of this research work is to investigate the residual strains induced by the presence of a exit hole and internal hollow geometry present in a 3D printed IN718 similar to that seen in a gas turbine blade. The specimens were manufactured with an internal hollow structure that ended with an exit hole, and fabricated by direct metal laser sintering additive manufacturing technique. Using this technique, metal powder was melted by a laser source and rapidly cooled to form the part layer by layer. Rapid heating and cooling generate large thermal gradients and residual stresses in the 3D printed material. To be aligned with industry standards, specimens were heat-treated to relieve most of the residual stresses as well as to investigate whether IN718 still preserved a nonhomogeneous stress state after the thermal treatment. Roughness and microstructure analysis was performed to understand the heat-treated sample properties. To investigate the volumetric residual strain, the neutron diffraction technique was used with a definite neutron wavelength. Bragg’s law was used to determine lattice spacing. Interplanar lattice spacing and stress-free state lattice spacings were measured to calculate the strains. Residual strains were measured in the x and y direction to understand the impact of the presence of a exit hole and internal hollow geometry. The results of volumetric residual strain in the x and y directions showed no significant variations in the distribution of the strain due to the presence of a hollow structure as well as the exit hole. Overall, no significant stress concentration was observed in the heat treated sample. Sample geometry, instrumentation for neutron diffraction, and material properties are discussed in detail in this paper.

Raju, Nandhini↗

Residual Strains in an Additively Processed Ni-based Superalloy Transpiration-Cooled Aerodynamic Leading Edge Structure using Neutron Diffraction

Selective Laser Melting (SLM) is a well-known additive manufacturing method based on a layer-by-layer building process that is capable of fabricating gas turbine Ni-based superalloy parts with complex and integrated cooling geometries that are typically not achievable using conventional casting methods. However, the impact of residual stress concentration on SLM component life is a concern. In this work, residual strains present at room temperature in an SLM Inconel 718 generic aerodynamic leading edge segment with transpiration cooling were investigated using neutron diffraction at Oak Ridge National Laboratory. This study reveals that areas of the part where complex cooling holes were printed exhibit residual tensile strains that can be detrimental to its integrity. The study paves the way for future studies of the design of cooling hole geometries and manufacturing parameters that achieve improved cooling while minimizing stress concentration effects.

Fouliard, Quentin↗

Combustion Kinetics Model Development & Fluid Property Experimental Investigation For Improved Design Of Supercritical CO 2 Power Cycle Components

Supercritical carbon dioxide (sCO 2 ) cycles are being investigated for the future of power generation and will contribute to a carbon-neutral future to combat the effects of climate change. These direct-fired closed cycles will produce power without adding significant pollutants to the atmosphere. For such cycles to be efficient, they will need to operate at significantly higher pressures (e.g., 300 atm for Allam Cycle) than existing systems (typically less than 40 atm). There is limited knowledge on combustion at these high pressures and with a high dilution of carbon dioxide. Also, various experimental and computational investigations and model developments have been performed by the University of Central Florida (UCF), Embry-Riddle Aeronautical University (ERAU), and Stanford University (S.U.) to improve the current knowledge base and support the design and development of sCO 2 combustors. This project's technical aspects include chemical kinetics development, fundamental sCO 2 combustion, combustion model and sub-model development, supercritical fluid injection characterization, and heat transfer characterization.

20 FOSSIL-FUELED POWER PLANTS↗

Techno-Economic Analysis of a Cryogenic Flux Capacitor for Grid Storage

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. The high energy density of CFC-stored hydrogen allows long durations of storage, such as daily to monthly cycling, which corresponds to approximately 10 to 100 hours of duration, respectively. The techno-economic analysis examines different types of hydrogen storage for commercial viability. The assessment includes the use of hydrogen blended with natural gas in a combined cycle gas turbine. The study provides results for a range of blends from 100% natural gas to 100% hydrogen. The required fuel usages are estimated for the intended application in a grid scenario that features large amounts of renewable penetration, 10 hours, and as a baseload, 100 hours. The study presents preliminary estimates of the capital cost of storage and operating cost of storage. In addition, the cost of firing natural gas and capturing the carbon dioxide (CO2) in a carbon capture and sequestration (CCS) system is assessed. Based on the study, it is shown that CFC can competitively meet performance and cost needs for grid-based energy storage.

08 HYDROGEN↗

Measurements of the Flow in the Vicinity of an Additively Manufactured Turbine Leading-Edge Using X-Ray Particle Tracking Velocimetry

X-ray particle tracking velocimetry (PTV) is performed, for the first time, to measure the velocity field inside a leading-edge of a turbine blade made by laser-additive-manufacturing (LAM) process. The traditional showerhead holes were replaced by a porous matrix in the leading-edge. The flow through such a leading-edge piece cannot be faithfully recreated by traditional prototype testing methods due to the surface roughness and imperfections caused by LAM process. Hence, direct measurement is the only option. However, it is difficult to measure flow inside such pieces with traditional velocimetry measurements due to the existence of metallic walls. Moreover, small internal size and high flow speeds call for a measurement technique with high spatial and temporal resolutions. To address these issues, we performed time-resolved X-ray PTV using the Advanced Photon Source (APS) synchrotron facility at the Argonne National Laboratory (ANL). A hydraulic system was constructed to run water, mixed with seeding particles, through the leading-edge piece. A high-speed camera captured the images of the seeding particles, which were later processed to create particle tracks. The time-averaged velocity field showed distinct pairs of vortices located in front of the porous outlet inside the leading-edge piece. The inlet channel showed reversed flow due to partial obstruction by the porous inlet of the test piece. Such knowledge of the flow field inside a leading-edge of a turbine blade will help us to design better cooling paths leading to higher cooling efficiency and increased life-span of a turbine blade.

42 ENGINEERING↗

Revision of Paschen's Law Relating to the ESD of Aerospace Vehicle Surfaces

The purpose of this work is to develop a version of Paschen's law that takes into account the flow of ambient gas past electrode surfaces. Paschen's law does not consider the flow of gas past an aerospace vehicle whose surfaces may be triboelectrically charged by dust or ice crystal impingement while traversing the atmosphere. The basic hypothesis of this work is that the number of electron-ion pairs created per unit distance between electrode surfaces is mitigated by the electron-ion pairs removed per unit distance by the flow of gas. The revised theoretical model must be a function of the mean velocity vxm of the ambient gas and reduce to Paschen's law when the mean velocity is zero. A new theoretical formulation of Paschen's law, taking into account the Mach number and compressible dynamic pressure, derived by the authors, will be discussed. This equation has been evaluated by wind tunnel experimentation. Initial data of the baseline wind tunnel experiments show results consistent with the hypothesis. This work may enhance the safety of aerospace vehicles through a redefinition of electrostatic launch commit criteria. It is also possible for new products, such as antistatic coatings, to be formulated based on this data.

electrostatic↗

Revision of Paschen's Law Relating to the ESD of Aerospace Vehicle Surfaces

The purpose of this work is to develop a version of Paschens law that takes into account the flow of ambient gas past electrode surfaces. Paschens law does not consider the flow of gas past an aerospace vehicle whose surfaces may be triboelectrically charged by dust or ice crystal impingement while traversing the atmosphere. The basic hypothesis of this work is that the number of electron-ion pairs created per unit distance between electrode surfaces is mitigated by the electron-ion pairs removed per unit distance by the flow of gas. The revised theoretical model must be a function of the mean velocity vxm of the ambient gas and reduce to Paschens law when the mean velocity is zero. A new theoretical formulation of Paschens law, taking into account the Mach number and compressible dynamic pressure, derived by the authors, will be discussed. This equation has been evaluated by wind tunnel experimentation. Initial data of the baseline wind tunnel experiments show results consistent with the hypothesis. This work may enhance the safety of aerospace vehicles through a redefinition of electrostatic launch commit criteria. It is also possible for new products, such as antistatic coatings, to be formulated based on this data.

discharge↗