Search NASA⌕ Search

Engineering topics

Karki, Krishna

Publications and source records attributed to Karki, Krishna.

Lasing in 15 atm CO 2 cell optically pumped by a Fe:ZnSe laser

10 µm lasing is studied in a compact CO 2 -He cell pressurized up to 15 atm when optically pumped by a ∼50 mJ Fe:ZnSe laser tunable around 4.3 µm. The optimal pump wavelength and partial pressure of CO 2 for generating 10 µm pulses are found to be ∼4.4 µm and 0.75 atm, respectively. Without cavity optimization, the optical-to-optical conversion efficiency reached ∼10% at a total pressure of 7 atm. The gain lifetime is measured to be ∼1 µs at pressures above 10 atm, indicating the feasibility of using high-pressure optically pumped CO 2 for the efficient amplification of picosecond 10 µm pulses.

Tovey, Dana↗

High energy (0.8 J) mechanically Q-switched 2.94 μm Er:YAG laser

We report a flashlamp pumped mechanically Q-switched (MQS) 2.94 μm Er:YAG laser based on a spinning mirror with a highest output energy of 805 mJ at a pulse duration of 61 ns and 13 MW of peak power at 1 Hz repetition rate. This record output energy was achieved with the use of 300 mm long MQS Er:YAG laser cavity consisting of a 70% output coupler, 7 × 120 mm AR coated Er(50%):YAG crystal, and 4200 rad/s angular speed of the spinning mirror. The pulse jitter was also measured by using optical triggering and was smaller than 10 ns for 150 ns Q-switched pulses, which could be applicable to many laser applications where precise synchronization of pulses is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Room temperature, nanosecond, 60 mJ/pulse Fe:ZnSe master oscillator power amplifier system operating at 3.8-5.0 µm

We report on a RT gain-switched Fe:ZnSe master oscillator power amplifier (MOPA) system tunable over 3.8–5.0 µm pumped by radiation of Er:YAG laser operating at 2.94 µm. The mechanically Q-switched Er:YAG laser with output energy up to 220 mJ was used as a pump source for a master oscillator and three-stage power amplifier. The maximum output energies in 200 ns pulses exceeded 60, 56, and 48 mJ at 4.4, 4.3, and 4.1 µm, respectively, under 220 mJ of pump energy. The extraction energy efficiencies were measured to be 25, 30, and 40% at the first, second, and third stages, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hot-pressed ceramic Fe:ZnSe gain-switched laser

We report the first room temperature gain-switched Fe:ZnSe hot-pressed ceramic laser pumped by 2.94 µm radiation of mechanically Q-switched Er:YAG laser. The maximum output energy at 4.2 µm was 41 mJ at 3 Hz repetition rate and 120 ns pulse duration. The measured slope efficiency was 25% with respect to the absorbed energy. This technique could be attractive for the future development of high-energy short-pulse solid-state mid-IR systems.

36 MATERIALS SCIENCE↗