Search NASA⌕ Search

Engineering topics

Karlsson, Toni Y

Publications and source records attributed to Karlsson, Toni Y.

MSTEC: Molten Salt Thermophysical Examination Capability

Description – shielded modular hotcell with an inert argon atmosphere, housing characterization equipment for determining thermophysical and thermochemical properties of high temperature liquids not limited to but focusing on TRU and irradiated fuel salts

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MSTEC: Molten Salt Thermophysical Examination Capability

Technical Description – a shielded modular hotcell with an inert argon atmosphere, housing characterization equipment for determining thermophysical and thermochemical properties of high temperature liquids not limited to but focusing on irradiated fuel salts Location – MFC, FCF, rm 35 Compatible Materials: Chloride, fluoride salts Fresh fuel salts and irradiated fuel salts Pyrophoric material - U, Pu metal Gases – H2, HCl, Cl2, HF, F2, NF3 Beryllium containing salts Many others

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrorefiner Speciation and Phase Model for Prediction of Operation Lifetime

The Mk IV electrorefiner (ER) at Idaho National Laboratory has recovered uranium metal from used nuclear fuels for 27 years. Thus, large quantities of fission product chlorides more electropositive than uranium have accumulated in the ER salt, increasing the complexity of phase equilibria and salt speciation. Importantly, the melt temperature of the salt increases with ER operation and will ultimately exceed design limits without intervention. Methods to remove fission products from molten chloride salt are known, but their implementation at scale is not yet demonstrated. In this work, historical ER composition and differential scanning calorimetry (DSC) are utilized to develop coupled speciation and chloride salt solution thermochemistry models, which enable accurate present-day analysis of ER salt as well as forecast its future disposition. The developed thermochemical models are applicable to chloride salts generally and have been made available in the Molten Salt Thermal Properties Database – Thermochemical.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Sampling Techniques and Analytical Approaches

Recent global interest in pyroprocessing and molten salt reactors has brought salt sampling methods and techniques back to the forefront of nuclear safeguards concerns. Issues with uranium supplies have also encouraged various countries to pursue advanced nuclear fuel cycles. Tracking nuclear material in molten salt has proven to be a challenge and updating molten salt sampling will greatly help in this endeavor. Molten salt is problematic to sample due to salt stratification, lack of homogeneity, solids, and difficulty with hot cell adaptations. Various salt sampling techniques have been used since before the 1960s including surface, spoon/spatula, and bar solidification. Since then, new types of sampling techniques have been developed to improve sampling results. These include rod/dip, pipet, suction, filtered sampling along with devices such as the Valve Core Sampler and the Multi-Level Sampler. These different approaches are being analyzed and improved upon along with developing requirements for an improved salt sampling device. Work continues to develop salt samplers that are more robust, easier to segment, collect at a specific depth, can work with filters, and can collect fines. Sampling parameters are also being narrowed in terms of stirring, settling time, filtration, depth, etc. In the future, we hope to address deficiencies for process control and nuclear material accountancy control by determining the best way to collect samples that minimizes contaminants and is representative. A compilation of salt sampling approaches, analyses techniques, and an evaluation of findings will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis and Thermal Property Investigations into Ternary Actinide Chloride Salt Systems Containing UCl3 and PuCl3

While regulators, the scientific community, and MSR developers still lack access to literature data on the thermal properties of clean fuel salts, even less information is available on the properties of fuel salts containing impurities. It is essential to understand, benchmark, and predict crucial data on the changes in thermal properties of fuel salt systems due to impurities arising from moisture, corrosion, and reactor operation (i.e., fission products). This research focuses on two actinide fuel salts (1) to investigate a worst-case scenario buildup of actinide fission product in a NaCl-UCl3 eutectic fuel salt and (2) to investigate NaCl-PuCl3 eutectic salt after 1000 hours of operation in a natural circulation flow loop flow to determine if corrosion or atmospheric (moisture/oxygen) products are present. For the first salt, a conservative assumption or worst-case scenario, for fission product buildup in a fuel salt was investigated by adding PuCl3 to eutectic 67 mol% NaCl – 33 mol% UCl3 salt resulting in a ternary salt having a composition of 61 mol% NaCl – 30 mol% UCl3 – 9mol% PuCl3. Addition of PuCl3 to eutectic NaCl-UCl3 resulted in a ternary salt that had a higher melting temperature than either the NaCl-PuCl3 or NaCl-UCl3 binary eutectic mixture. Addition of PuCl3 also resulted in an increase in density which was expected. The second salt was extracted from a micro loop. The composition of the fuel (primary) salt prior to flow loop operations was determined to be 64 mol% NaCl – 36 mol% PuCl3, however, the post-flow loop salt showed increased levels of MgCl2 and NaCl changing the salt composition to 10 mol% MgCl2 – 63mol% NaCl – 26mol% PuCl3) indicating the primary salt interacted with the rinse salt. Analysis of the post flow loop salt detected low concentrations of Al, Ni, Co, Nb, and Zr, most likely corrosion products from the flow loop material of construction. Contamination of the fuel salt (with the rinse salt NaCl-MgCl2) decreased the density by approximately 10% and reduced the onset of melting temperature by 50 °C, from 451 °C to approximately 400 °C. Results from the fission product simulated salt (61 mol% NaCl – 30 mol% UCl3 – 9mol% PuCl3) and the corrosion product salt (10 mol% MgCl2 – 63mol% NaCl – 26mol% PuCl3) will be included in two separate manuscripts for submission to peer-reviewed journals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TMS 2023 - Methodology and Density of PuCl3-NaCl Mixtures

The development of molten salt reactors and their associated components demands reliable and accurate thermophysical property data for design and validation. A candidate fuel salt, PuCl3-NaCl (36 mol% PuCl3) has been synthesized and studied at the Idaho National Laboratory. This study has determined the density of PuCl3-NaCl at multiple compositions and temperatures, providing data for validation of modeling efforts and making improvements on the buoyancy method for density measurements of actinide-bearing molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wetting Properties of Molten Salts

Wettability is a key piece of information in understanding the behavior of molten salts at material interfaces. Wettability is most easily characterized by contact angle which is measurable using the sessile drop method. A modified sessile drop method was used to measure the contact angle of the LiCl-KCl eutectic at varying temperatures on Nickel 200, Hastelloy C276, Glassy Carbon, and MACOR machinable ceramic. The contact angle was used with existing surface temperature data to find the work of adhesion at various temperatures. Finally, problems encountered during the experiment are listed and possible improvements are provided.

36 MATERIALS SCIENCE↗

Synthesis and Thermophysical Property Determination of NaCl-PuCl3 Salts

Currently, a knowledge gap exists in the available data and understanding of thermophysical properties relating to fresh fuel salts, especially those containing plutonium. Determination of this data is necessary for the design and construction of test reactors, as well as the licensing of future commercial molten salt reactors. Thermophysical properties such as melting temperature, salt stability, density, and heat capacity were determined on synthesized eutectic NaCl-PuCl3 and a more sodium rich composition containing 25 mol% PuCl3. These measurements document the baseline properties of the salt as a function of temperature for future experiments on irradiated fuel salt which will provide a holistic perspective on the change of thermophysical properties during reactor operations. It was determined that the NaCl-PuCl3 ingot synthesized for this study contained 63.4 mol% NaCl, 36.3 mol% PuCl3, and was 99.7% pure. Upon heating it was shown that the NaCl- PuCl3 eutectic was stable at temperatures of 800°C. The onset of melting occurred at 541°C and the enthalpy of fusion was determined to be 140.7 ± 8.4 J/g. Specific heat capacity measurements showed a slightly decreasing trend with respect to temperature in the liquid phase ranging from 0.67 to 0.57 J/g·K, with an average value of 0.637 ± 0.03 J/g·K (104 ± 5 J/mol·K) between 500 to 720°C. Three independent trials of the molten NaCl-PuCl3 eutectic salt found the density to be ?(T) = 3.8589 – 9.5342·10-4 T(°C), validated between 500 to 800°C. In addition to salt synthesis and experimentally determining thermodynamic properties, Ab Initio molecular dynamic (AIMD) simulations were used to calculate density and heat capacity values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

US NIC MFC Tour Posters

The United States Nuclear Industry Council will be visiting MFC.

99 GENERAL AND MISCELLANEOUS↗

Suggestions on the Vapor Pressure Determination of Molten Salts

The knowledge of the thermophysical properties of coolant and fuel in molten salts nuclear reactors (MSRs), such as thermal stability and vapor pressure, are of remarkable interest, particularly for simulating safe reactor operations. Molten salt reactorsMSRs use molten salt mixtures as the primary coolant and/or fuel and are expected to operate up to 800 °C. With the revival of interest in deploying MSRs, complete thermophysical and thermochemical characterization of these materials is of interest to industry, regulators, and researchers. Vapor pressure data for molten salts are scarce in the literature, both for pure salts but especially for eutectic mixtures. This report describes the effusion method, which consist of measuring the rate of escape of vapor molecules through a small orifice for the determination of the vapor pressure of compounds and may be useful on compounds such as molten salts. Thermogravimetric analysis records the mass loss as a function of time and temperature. There are two equations that can be used to relate the mass loss rate with the vapor pressure: (1) the Knudsen equation and (2) the Langmuir equation. To apply these equations, the system needs to reach a pseudo (or near) equilibrium condition. Therefore, the experimental conditions must be such that allow the condensed and the vapor/gas phases to be in equilibrium. In order to accomplish equilibrium like conditions, the sample must be in an almost-sealed cell except for a small orifice, from where the vapor escapes. In the Knudsen method vacuum is applied to eliminate the effect that the presence of other gas molecules could have on the evaporation rate of the sample. However, Langmuir alleged that in certain conditions, such as at low temperatures and/or when the vapor pressure is low, the rate of evaporation of a substance is independent of the presence of vapor around it. For that reason, some researchers, when measuring the mass loss of a substance with a predictable low vapor pressure, do not apply vacuum when using the Langmuir equation. However, they use a standard substance to parameterize the experimental setup. The use of one equation or the other will depend on the characteristics of the sample and the availability of an appropriate standard. Some important aspects related to the nature of the samples and vapor pressure measurements are described for future consideration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review—Electrochemical Measurements in Molten Salt Systems: A Guide and Perspective

Practical information is provided on electrochemical measurements in molten salt systems. The emphasis is on chloride and fluoride systems, but the principles are applicable to any high temperature molten salt or molten oxide electrolyte system. Considerations are given to topics such as the functionality of electrochemical measurement equipment, reference electrodes, materials selection and chemical compatibility, interpretation of electrochemical measurement signals, molten salt properties, and laboratory practices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗