Search NASA⌕ Search

Engineering topics

Kato, Seigo

Publications and source records attributed to Kato, Seigo.

High-precision three-dimensional field mapping of a high resolution magnetic spectrometer for hypernuclear spectroscopy at JLab

The High Resolution Kaon Spectrometer (HKS), which consists of two quadrupole magnets and one dipole magnet, was designed and constructed for high-resolution spectroscopy of hypernuclei using the (e,e'K+) reaction in Hall C, Jefferson Lab (JLab). It was used to analyze momenta of around 1.2 GeV/c K^+ s with a resolution of 2 ×10^-4 (FWHM). To achieve the target resolution, a full three-dimensional magnetic field measurement of each magnet was successfully performed, and a full three-dimensional magnetic field map of the HKS magnets was reconstructed. Using the measured field map, the initial reconstruction function was generated. The target resolution would be achieved via careful tuning of the reconstruction function of HKS with the p(e,e'K+)Lambda,Sigma^0 and C-12 (e,e'K+)12_Lambda B_g.s. reactions. After tuning of the initial reconstruction function generated from the measured map, the estimated HKS momentum resolution was 2.2×10^-4 (FWHM).

Fujii, Yuu (ORCID:0000000166252241)↗

Observation of the Λ ⁷He Hypernucleus by the (e, e'K⁺) Reaction

An experiment with a newly developed high-resolution kaon spectrometer and a scattered electron spectrometer with a novel configuration was performed in Hall C at Jefferson Lab. The ground state of a neutron-rich hypernucleus, He Λ ⁷, was observed for the first time with the (e, e'K⁺) reaction with an energy resolution of ~0.6 MeV. This resolution is the best reported to date for hypernuclear reaction spectroscopy. The He Λ ⁷ binding energy supplies the last missing information of the A=7, T=1 hypernuclear isotriplet, providing a new input for the charge symmetry breaking effect of the ΛN potential.

Nakamura, S. N.↗

R&D for the Post-EP Processes of Superconducting RF Cavity

The Electro-Polishing (EP) process is the best candidate of final surface treatment for the production of ILC cavities. Nevertheless, the broad distribution of the gradient caused by field emitters in cavities is sitll a serious problem for the EP process. A candidate source of field emitter is the sulfur component which is produced in the EP process and remains the inner-surface of cavities. We studied the effect of Ethanole- and degreaser-rinse processes after the EP process by a unique method. Moreover, we tried to test the sponge cleaning as the post-EP process to remove the field emitter inside the cavcity. This article describe the results of series tests of the post-EP process at KEK.

36 MATERIALS SCIENCE↗

Studies on the Electro-Polishing process with Nb sample plates at KEK

In this article, two subjects would be described. the first subject is on the production of stains on the surface of Nb sample plates in Electro-polishing (EP) process and the second subject is on the development of defects/pits in the EP process on the surface of a Nb sample plate. Recently, some 9-cell cavities were treated with new EP acid at KEK and the performance of these cavities were limited by heavy field emissions. On the inside surface of these cavities, brown stains were observed. We made an effort to reproduce the brown stains on Nb sample plates with an EP setup in laboratory with varying the concentration of Nibium in the EP acid. We found that the brown stains would appear only when processed with new EP acid. In the second subject, we made artificial pits on the surface of a Nb-sample plate and observed the development of the pits after each step of 30um-EP process where 120um was removed in total by the EP process. This article describes these series EP-tests with Nb sample plates at KEK.

36 MATERIALS SCIENCE↗

Hypernuclear spectroscopy program at JLab Hall C

DOI: http://dx.doi.org/10.1016/j.nuclphysa.2008.01.029 Hypernuclear production by the (e,e?K+) reaction has unique advantages in hypernuclear spectroscopy of the S=?1 regime. The second-generation spectroscopy experiment on 12C, 7Li and 28Si targets has been recently carried out at JLab Hall C with a new experimental configuration (Tilt method) and also using a new high-resolution kaon spectrometer (HKS). The experiment is described and preliminary results are presented together with the empasis of significance of the (e,e?K+) reaction for ? hypernuclear spectroscopy and its future prospects.

Hashimoto, Osamu↗