Search NASA⌕ Search

Engineering topics

Kaufman, M. I.

Publications and source records attributed to Kaufman, M. I..

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

Characterization of the Mercury pulsed power x-ray source spectrum using multichannel density aerogel Cherenkov detectors

The Aerogel Cherenkov Detector for Cygnus (ACD/C) is a time-dependent, x-ray spectral detector that uses SiO 2 aerogels spanning an index of refraction (n = 1.02–1.07) corresponding to a 1.1–2.3 MeV x-ray energy threshold. The ACD/C was developed for pulsed power x-ray sources like Cygnus located at the Nevada National Site and Mercury located at the Naval Research Laboratory (NRL). Aerogels sit between the measurement capabilities of gas (>2 MeV) and solids such as fused silica (>0.3 MeV). The detector uses an aluminum converter to Compton scatter incoming x-rays and create relativistic electrons, which produce Cherenkov light in an aerogel or a fused silica medium. The ACD/C was fielded at the NRL when Mercury was tuned to produce up to 4.8 MeV endpoint bremsstrahlung. Despite a high radiation and electromagnetic interference background, the ACD/C was able to achieve high signal over noise across five aerogel densities and fused silica, including a signal to noise for a 1.1 MeV aerogel threshold. Previous experiments at Cygnus observed a signal that was comparable to the noise (1×) at the same threshold. The ACD/C observed time-resolved rise and fall times for different energy thresholds of the photon spectrum. Finally, Monte Carlo simulations of the ACD/C’s aerogel response curves were folded with a simulation of Mercury’s photon energy spectrum and agree within the error to the observed result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Measurements of Cygnus X-ray Production Using Aerogel Cherenkov Detector

Aerogel Cherenkov Detector for Cygnus (ACD/C) has been developed to provide time-dependent x-ray spectral information from Cygnus – an intense flash x-ray source operated at the Nevada National Security Site. Time-resolved Cygnus x-ray signals were measured at three energy thresholds: 1.3 MeV (by 197 mg/cc aerogel), 1.1 MeV (by 260 mg/cc aerogel), and 0.3 MeV (by quartz). ACD/C data qualitatively suggest that the high-energy x-ray peak exists on a shorter timescale than the Cygnus voltage or current pulse. A time-dependent, x-ray spectral information can improve the understanding of the physics of dense objects radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrum

An aerogel Cherenkov detector is proposed to measure the X-ray energy spectrum from the Cygnus—intense flash X-ray source operated at the Nevada National Security Site. An array of aerogels set at a variety of thresholds between 1 and 3 MeV will be adequate to map out the bremsstrahlung X-ray production of the Cygnus, where the maximum energy of the spectrum is normally around 2.5 MeV. In addition to the Cherenkov radiation from aerogels, one possible competing light-production mechanism is optical transition radiation (OTR), which may be significant in aerogels due to the large number of transitions from SiO{sub 2} clusters to vacuum voids. To examine whether OTR is a problem, four aerogel samples were tested using a mono-energetic electron beam (varied in the range of 1–3 MeV) at NSTec Los Alamos Operations. It was demonstrated that aerogels can be used as a Cherenkov medium, where the rate of the light production is about two orders magnitude higher when the electron beam energy is above threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ejecta Particle-Size Measurements in Vacuum and Helium Gas using Ultraviolet In-Line Fraunhofer Holography

An Ultraviolet (UV) in-line Fraunhofer holography diagnostic has been developed for making high-resolution spatial measurements of ejecta particles traveling at many mm/μsec. This report will discuss the development of the diagnostic including the high-powered laser system and high-resolution optical relay system. In addition, the system required to reconstruct the images from the hologram and the corresponding analysis of those images to extract particles will also be described. Finally, results from six high-explosive (HE), shock-driven Sn ejecta experiments will be presented. Particle size distributions will be shown that cover most of the ejecta velocities for experiments conducted in a vacuum, and helium gas environments. In addition, a modification has been made to the laser system that produces two laser pulses separated by 6.8 ns. This double-pulsed capability allows a superposition of two holograms to be acquired at two different times, thus allowing ejecta velocities to be measured directly. Results from this double pulsed experiment will be described.

36 MATERIALS SCIENCE↗

Ejecta Particle-Size Measurements in Vacuum and Helium Gas using Ultraviolet In-Line Fraunhofer Holography

An ultraviolet (UV) in-line Fraunhofer holography diagnostic has been developed for making high-resolution spatial measurements of ejecta particles traveling at many mm/μsec. This report will discuss the development of the diagnostic, including the high-powered laser system and high-resolution optical relay system. In addition, we will also describe the system required to reconstruct the images from the hologram and the corresponding analysis of those images to extract particles. Finally, we will present results from six high-explosive (HE), shock-driven Sn-ejecta experiments. Particle-size distributions will be shown that cover most of the ejecta velocities for experiments conducted in a vacuum, and helium gas environments. In addition, a modification has been made to the laser system that produces two laser pulses separated by 6.8 ns. This double-pulsed capability allows a superposition of two holograms to be acquired at two different times, thus allowing ejecta velocities to be measured directly. Results from this double-pulsed experiment will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

Telecentric Zoom Lens Designed for the Cygnus X-Ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm. All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure and can be used in either a vertical or horizontal orientation.

Cygnus, telecentric zoom lens↗

Mach-Zehnder recording systems for pulsed power diagnostics

Fiber-optic transmission and recording systems, based on Mach-Zehnder modulators, have been developed and installed at the National Ignition Facility (NIF), and are being developed for other pulsed-power facilities such as the Z accelerator at Sandia, with different requirements. We present the design and performance characteristics for the mature analog links, based on the system developed for the Gamma Reaction History diagnostic at the OMEGA laser and at NIF. For a single detector channel, two Mach-Zehnders are used to provide high dynamic range at the full recording bandwidth with no gaps in the coverage. We present laboratory and shot data to estimate upper limits on the radiation effects as they impact recorded data quality. Finally, we will assess the technology readiness level for mature and developing implementations of Mach-Zehnder links for these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗