Search NASA⌕ Search

Engineering topics

Kaufman, Morris I.

Publications and source records attributed to Kaufman, Morris I..

Optical Relays for Imaging Scintillators

Presentation at the "Multi-Probe Radiography IV: Detectors and Image Analysis" workshop, to be held at LANL, in the Rosen Auditorium. Host is Bob Reinovsky, LANL, 505-699-1127. LANL Point of Contact: Mariana Alvarado Alvarez, LANL, 505-665-7994.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Topics in Optical Design, Manufacturing, and Analysis

Presentation to be given at the LANL Detectors and Analysis Workshop December 5-6, 2023. This STIP is a resubmission of STIP 35977839 (an incorrect version of the document was sent through the STIP process previously).

42 ENGINEERING↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (ΔT ∙ Δα) should be less than 189 ppm, where ΔT is the temperature excursion and Δα is the difference in glass coefficient of thermal expansion. If the product (ΔT ∙ Δα) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets.

47 OTHER INSTRUMENTATION↗

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (∆T ∙ ∆α) should be less than 189 ppm, where ∆T is the temperature excursion and ∆α is the difference in glass coefficient of thermal expansion. If the product (∆T ∙ ∆α) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets

42 ENGINEERING↗

New Optical Designs for Radiation Imaging Systems [Slides]

Presentation to be presented during the first annual Prompt Radiation Detection and Imaging Workshop, hosted by the NNSS Dynamic Instruments Team, April 25–28, 2022, at NLV C-01 Auditorium and via Webex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗