Search NASA⌕ Search

Engineering topics

Kawakami, S.

Publications and source records attributed to Kawakami, S..

Evolution of the two-neutron configuration from 11 Li to 13 Li

In this work we investigate the two-neutron decay of 13 Li and of the excited states of 11 Li populated via one-proton removal from 14 Be and 12 Be, respectively. A phenomenological model is used to describe the decay of 11 Li and 13 Li. While the first one displays important sequential components, the second one appears dominated by the direct two-neutron decay. A microscopic three-body model is used to extract information on the spatial configuration of the emitted neutrons before the decay and shows that the average distance between the neutrons increases going from 11 Li to 13 Li.

Dineutron decay↗

Variability in Ozone in the Tropical Upper Troposphere-Lower Stratosphere from the 1998-2000 SHADOZ (Southern Hemisphere Additional Ozonesondes) Data

The first view of lower stratospheric and upper tropospheric structure from sondes is provided by a 3-year, 10-site record from the Southern Hemisphere ADditional OZonesondes (SHADOZ) network: . Observations covering 1998-2000 were made over Ascension Island; Nairobi, Kenya; Irene, South Africa; Reunion Island; Watukosek, Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil. Taking the UT/LS (upper troposphere- lower stratosphere) as the region between 12 and 17 km, we examine ozone variability in this region on a week-to-week and seasonal basis. The tropopause is lower in September-October-November than in March-April-May, when ozone is a minimum at most SHADOZ stations. A zonal wave-one pattern (referring to ozone mixing ratios greater over the Atlantic and adjacent continents than over the Pacific and eastern Indian Ocean), persists all year. The wave, predominantly in the troposphere and with variable magnitude, appears to be due to general circulation - with subsidence over the Atlantic and frequent deep convection over the Pacific and Indian Ocean. The variability of deep convection most prominent at Java, Fiji, Samoa and Natal - is explored in time-vs-altitude ozone curtains. Stratospheric incursions into the troposphere are most prominent in soundings at Irene and Reunion Island.

Thompson, A. M.↗

Impact of Lightning and Convection on Reactive Nitrogen in the Tropical Free Troposphere

Latitudinal distributions of NO, NO(y), O3, CO, CH3I, and H2O mixing ratios at 8.9-12 km were obtained between 30deg N and 1deg S by DC-8 aircraft measurements made in February 1994 during Pacific Exploratory Mission-West B (PEM-West B). Very low NO(y), mixing ratios with a median value of 51 parts per trillion by volume (pptv) were observed at 9.5-12 km at 1deg N-14deg N during two flights made within 3 days. A very low median O3 mixing ratio of 19 parts per billion by volume (ppbv) and high mixing ratios of H2O and CH3I were simultaneously observed, suggesting that the low NO(y), values were probably due to the convective transport of air from the tropical marine boundary layer to this altitude. The median NO(y)/O3 ratio being a factor of 2 smaller than in the air masses in the tropical marine boundary layer might suggest the possibility that the heterogeneous removal of HNO3 during convective transport further reduced NO(y) levels. In addition to the measurements between 9.5 and 12 km, low values of NO(y) and O3 were observed between 4 and 12 km at 1deg N. Divergent wind fields at 200 and 1000 hPa and infrared (IR) cloud images show that there was large scale convection (greater than 1000 km x 1000 km) in the northeast of New Guinea Island centered around Odeg S and 150deg E as part of systematic convective activity of the Intertropical Convergence Zone (ITCZ) and the South Pacific Convergence Zone (SPCZ). This type of large scale convection could have transported air with low levels of NO(y) and O3 to the middle and upper troposphere over a wide area in the tropics. On the other hand, NO mixing ratios of 50-200 pptv and high NQ,/NOY ratios of 0.4-0.6 were observed at 9.5 km between 4deg S and 10deg S. High H2O Mixing ratios of 600-1200 parts per million by volume (ppmv) and low CO mixing ratios of 65 ppbv observed in the air mass indicated that the high NO values were probably due to NO production by lightning. Satellite observations showed relatively frequent lightning flashes over the New Guinea Island for 3 days prior to the aircraft measurements. These results are considered to be consistent with the idea that, in general, marine convection is not accompanied by lightning activity, whereas convection over land is. Because of the large areal extent of the influences from these processes, the convective transport of low NO(y) air and NO production by lightning should play critical roles in controlling the abundance of reactive nitrogen in the equatorial region.

Kawakami, S.↗

Reactive Nitrogen and its Correlation with O3 and CO Over the Pacific in Winter and Early Spring

Measurements of NO, NO(y), O3, and CO were made during NASA's Global Tropospheric Experiment/Pacific Exploratory Mission-West B (GTE/PEM-West B) carried out over the western Pacific in February and March 1994. NO(x) was calculated from NO using a photostationary state model ((NO(x)(sub mc)). Correlations between these species are presented, and some insights into the sources of NO(x) and NO(y) are described. The boundaries between the lower, middle, and upper troposphere have been defined at potential temperatures of 311 K and 328 K, which correspond to the geometric altitudes of about 5 and 9 km at 30degN. Enhancements in the mixing ratios of NO(y) and CO were observed in the lower and middle troposphere. A positive correlation was found between these two species suggesting that the high NO(y) values were due to anthropogenic emissions over the continental surface. On the other hand, O3 increased little with increase in CO. As a result, NO(y)/O3 ratios were higher in air more influenced by pollution. NO(y), values in 55 and 28% of the air masses sampled in the lower and middle troposphere, respectively, were higher than the clean free tropospheric NO(y)-O3 range when O3 values simultaneously observed were used. High (NOx)mc/NOy ratios between 0.15 and 0.3 were found in the boundary layer with relatively low mixing ratios of CO and NOy during the three flights. These air masses were transported from a higher altitude (approximately 5 km) and a higher latitude (approximately 50degN) within a few days. The peroxyacetyl nitrate (PAN)/NO(y) ratios were generally high (approximately 0.4) in these air masses, and the thermal decomposition of PAN was a probable source of NO(x). In the middle troposphere the (NO(x))mc mixing ratio did not generally increase with NO(y) or CO, suggesting that the transport of air masses affected by anthropogenic emissions did not increase the NO(x) level significantly. In the upper troposphere, very minor effects from the continental surface sources were seen in the CO mixing ratio. By contrast, NO(y) values in 33% of the air masses were higher than those expected when stratospheric air intrusion is assumed to be a single source of NO(y) based on NO(y)-O3 correlation analyses. This result suggests significant free tropospheric NO(y) sources, namely exhaust from the aircraft and NO production by lightning activity. In fact, spikes in the (NO(x))(sub m)c mixing ratios were observed near the aircraft corridor south of Tokyo at an altitude of 10 km. These two free tropospheric NO(x) sources were considered to be important in determining the levels of the upper tropospheric NO(x) and NO(y) during PEM-West B.

Koike, M.↗

Muon and neutrino results from KGF experiment at a depth of 7000 hg/square cm

The KGF nucleon decay experiment at a depth of 7000 hg/sq cm has provided valuable data on muons and neutrinos. The detector comprised of 34 crossed layers of proportional counters (cross section 10 x 10 sq cm; lengths 4m and 6m) sandwiched between 1.2 cm thick iron plates can record tracks of charged particles to an accuracy of 1 deg from tracks that traverse the whole of the detector. A special two-fold coincidence system enables the detector to record charged particles that enter at very large zenith angles. In a live time of 3.6 years about 2600 events have been recorded. These events include atmospheric muons, neutrino induced muons from rock, stopping muons, showers and events which have their production vertex inside the detectors. The results on atmospheric muons and neutrino events are presented.

Krishnaswamy, M. R.↗

Limits on monopole fluxes from KFG experiment

The nucleon decay experiment at KGF at a depth of 2.3 Km is eminently suited for the search of Grand Unified theory (GUT) monopoles, whose velocities at the present epoch are predicted to be around 0.001C. At this depth the cosmic ray background is at a level 2/day in the detector of size 4m x 6m x 3.7m and one can look for monopoles traversing the detector in all directions, using three methods, i.e., (1) dE/dx (ionization); (2) time of flight and (3) catalysis of nucleon decay. The detector is composed of 34 layers of proportional counters arranged in horizontal planes one above the other in an orthogonal maxtrix. Each of the 1594 counters are instrumented to measure ionization in the gas (90% Argon + 10% Methane) as well as the time of arrival of particles.

Krishnaswamy, M. R.↗

Results on nucleon life-time from the Kolar gold field experiment

The KGF nucleon decay experiment has been in operation since October 1980 with a 140 ton calorimetric detector at a depth of 2.3 Km underground. The detector comprises 34 layers of proportional counters arranged in an orthogonal geometry with 12 mm thick iron plates in between successive layers. The proportional counters are made up of square (10 x 10 square centimeters) iron plates of wall thickness 2.3 mm. Each of the 1600 counters is instrumented to provide data on ionization, DE/dx and arrival time. The visible energy of a particle is determined to an accuracy of approximately 20% from the ionization and range of its track. The end point ionization of a stopping track provides the direction of motion as well as the nature of the particle (mu/pi,k,p). Decay of mu is recorded with an overall efficiency of only 20% in view of the thickness of 13 g/square centimeters between successive layers.

Krishnaswamy, M. R.↗

Data acquisition system for phase-2 KGF proton decay experiment

Phase-2 of KGF proton decay experiment using 4000 proportional counters will start operating from middle of 1985. The detection systems, in addition to measuring the time information to an accuracy of 200 n see, also records ionization in the hit counters. It also monitors different characteristics of the counters like pulse height spectrum, pulse width spectrum and counting rate. The acquisition system is discussed.

Krishnaswamy, M. R.↗