Multiparameter measurement utilizing poloidal polarimeter for burning plasma reactor

The authors have made the basic and applied research on the polarimeter for plasma diagnostics. Recently, the authors have proposed an application of multiparameter measurement (magnetic field, B, electron density, n{sub e}, electron temperature, T{sub e}, and total plasma current, I{sub p}) utilizing polarimeter to future fusion reactors. In this proceedings, the brief review of the polarimeter, the principle of the multiparameter measurement and the progress of the research on the multiparameter measurement are explained. The measurement method that the authors have proposed is suitable for the reactor for the following reasons; multiparameters can be obtained from a small number of diagnostics, the proposed method does not depend on time-history, and far-infrared light utilized by the polarimeter is less sensitive to degradation of of optical components. Taking into account the measuring error, performance assessment of the proposed method was carried. Assuming that the error of Δθ and Δε were 0.1° and 0.6°, respectively, the error of reconstructed j{sub φ}, n{sub e} and T{sub e} were 12 %, 8.4 % and 31 %, respectively. This study has shown that the reconstruction error can be decreased by increasing the number of the wavelength of the probing laser and by increasing the number of the viewing chords. For example, By increasing the number of viewing chords to forty-five, the error of j{sub φ}, n{sub e} and T{sub e} were reduced to 4.4 %, 4.4 %, and 17 %, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new method for determining the plasma electron density using optical frequency comb interferometer

A new method of plasma electron density measurement using interferometric phases (fractional fringes) of an optical frequency comb interferometer is proposed. Using the characteristics of the optical frequency comb laser, high density measurement can be achieved without fringe counting errors. Simulations show that the short wavelength and wide wavelength range of the laser source and low noise in interferometric phases measurements are effective to reduce ambiguity of measured density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separation of finite electron temperature effect on plasma polarimetry

This study demonstrates the separation of the finite electron temperature on the plasma polarimetry in the magnetic confined fusion plasma for the first time. Approximate solutions of the transformed Stokes equation, including the relativistic effect, suggest that the orientation angle, {theta}, and ellipticity angle, {epsilon}, of polarization state have different dependency on the electron density, n{sub e}, and the electron temperature, T{sub e}, and that the separation of n{sub e} and T{sub e} from {theta} and {epsilon} is possible in principle. We carry out the equilibrium and kinetic reconstruction of tokamak plasma when the central electron density was 10{sup 20} m{sup -3}, and the central electron temperatures were 5, 10, 20, and 30 keV. For both cases when a total plasma current, I{sub p}, is known and when I{sub p} is unknown, the profiles of plasma current density, j{sub {phi}}, n{sub e}, and T{sub e} are successfully reconstructed. The reconstruction of j{sub {phi}} without the information of I{sub p} indicates the new method of I{sub p} measurement applicable to steady state operation of tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new method for determining the plasma electron density using three-color interferometer

A new method for determining the plasma electron density using the fractional fringes on three-color interferometer is proposed. Integrated phase shift on each interferometer is derived without using the temporal history of the fractional fringes. The dependence on the fringe resolution and the electrical noise are simulated on the wavelengths of CO{sub 2} laser. Short-time integrations of the fractional fringes enhance the reliability of this method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗