Search NASA⌕ Search

Engineering topics

Kaye, Willy

Publications and source records attributed to Kaye, Willy.

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Multimodal Data Fusion with 3D Gamma-Ray Imaging for Safeguards (2023 Annual Report)

Improve the quantitative results obtained from 3D gamma-ray imagers for use in safeguards inspections. In FY23 the work focused on continuing to improve the numerical results obtained with gamma-ray imagers and explore approaches to project such data onto 3D structures mapped with Self Localization and Mapping (SLAM) hardware and software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NDA Tech: Multimodal Data Fusion with 3D Gamma-Ray Imaging for Safeguards

The ultimate project goal is to improve quantitative results obtained by the IAEA with the H420 gamma ray imager. Distribution to the IAEA will be through incorporation of project results into the software provided with the device by our commercial partner, H3D, Inc. Toward achieving that goal, we have started discussions with H3D to identify the requisite software components and how they will mesh with their own internally developed contextual data systems and other extant software components. We have identified the coded-aperture response data cube as a key structure. Discussions on contextual imaging were informative but somewhat inconclusive as the project lead on contextual data (LBNL) has not been available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drone Video Platform—Collision Avoidance, Situational Awareness, and Communications

Small unmanned aerial systems are ideal for delivering sensors into areas that are inaccessible or too dangerous for human entry or manned aircraft over-flights. The systems can fly low and slow for enhanced sensitivity and in tight spaces where ordinary aircraft could never fit. We have configured and flown sensor payloads for radiation, chemical, and optical detection on small fixed-wing and rotary-wing aircraft. All the sensor packages provide telemetry, GPS coordinates, LIDAR distance ranging, and absolute time of day to microsecond accuracy. Payload weights range from less than 1 kg up to 5.5 kg. Currently, communications are over 2.4 GHz and 915 MHz radios, as well as over 4G LTE cellular data links. Real-time data feeds from the sensor payloads to web browser clients anywhere in the world are possible via a virtual EC2 server on the Amazon AWS cloud. In FY 2019, the Nevada National Security Site teamed with Virginia Tech, H3D Corp., and Unmanned Systems, Inc. to accomplish the four flight missions described in this report. A large part of this year’s mission goals were to demonstrate the ability to fly beyond visual line of sight (BVLOS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensor payloads for small unmanned aerial vehicles

Small unmanned aerial systems (sUAS) are ideal for delivering sensors into areas that are inaccessible or too dangerous for human entry or manned aircraft over-flights. The systems can fly low and slow for enhanced sensitivity, and they can get into tight spaces where ordinary aircraft would never attempt to fly. We have configured and flown sensor payloads for radiation, chemical, and optical detection on small fixed wing and rotary wing aircraft. For radiation detection we have flown packages consisting of sodium iodide (NaI), lanthanum bromide (LaBr3), and cadmium-zinc-telluride (CZT) gamma spectrometers, and we have also flown a CZT gamma imaging detector. The chemical sensing package consists of surface catalytic detectors for real-time chemical sensing, and a multi-tube chemical sampler that can be post-flight analyzed with a gas chromatograph mass spectrometer (GCMS). The optical package comprises a small spectrometer with wavelength sensitivity from 200 nm to 900 nm, and it has successfully collected burst light spectra from small explosive detonations. All the sensor packages provide telemetry, GPS coordinates, LIDAR distance ranging, and absolute time of day to microsecond accuracy. Payload weights range from less than 1 kg up to 5.5 kg, and they have flown on Sandstorm and T-28 fixed wing drones, on a custom-built heavy-lift hex-copter, a 3DR Solo quad-copter, and a T-Rex 700 helicopter. Communications are over 2.4 GHz, 915 MHz radios, and 4G LTE cellular data links. Real time data feeds from the sensor payloads to web browser clients anywhere in the world are possible via a virtual server on the Amazon AWS cloud.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drone Video Platform—Collision Avoidance, Situational Awareness, and Communications STL-039-17, Year 2 of 2

At the beginning of FY 2018, the collision avoidance task of this project was dropped because it had become a “commercial off-the-shelf” product for rotary drones, but it was still considered a very difficult problem for fixed wing drones. In the second quarter of FY 2018, R. Trainham took over the project and decided to redirect efforts into testing a variety of sensors on a variety of platforms. The core module task was also dropped from the project because it duplicated what was already available commercially. Since last year’s SDRD final review, we have conducted flight tests in Idaho, Montana, Nevada, and Wisconsin. We have flown five different gamma detectors, a chemical detector and sampler, an optical spectrometer, and a point LIDAR on quadcopters, hexcopters, and the fixed wing T-28 and Sandstorm. We have collaborated with H3D, USI, Virginia Tech, and ORNL. In the coming year, we will continue those collaborations, and will add BYU and INL as collaborators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nevada National Security Site Site-Directed Research and Development Report (FY 2018 Annual Report)

This report compiles multiple articles describing activities developed and performed under the Site-Directed Research and Development Program for the benefit the Nation during Fiscal Year 2018. Sustained investment and ongoing core innovation are the keys to successful research and development programs. These elements drive the Site-Directed Research and Development (SDRD) Program and provide solutions to some of the most challenging problems our nation and our allies face. Our Nevada enterprise, consisting of both our management and operating entity and our NNSA field office, is aggressively investing in SDRD and injecting innovation through strategic partnerships. Our partnerships with universities, industry, and our sister institutions within the National Nuclear Security Administration (NNSA) build upon our core capabilities and allow us to create innovative solutions to support our mission requirements. In 2018, we raised the investment level of SDRD for only the second time in the history of the program. Nearly at our congressionally authorized limit, SDRD has substantial resources to successfully address numerous issues. Investment is only one part of the equation; innovation is generated through collaborations that bring discovery and provide the “technical differentiation” and the return on investment we seek. This report demonstrates an enduring theme of how partnerships help us drive the best outcomes and provide the maximum impact possible, while using our resources efficiently.

36 MATERIALS SCIENCE↗