Search NASA⌕ Search

Engineering topics

Kazakov, S

Publications and source records attributed to Kazakov, S.

Concept em design of the 650 MHz cavities for the Project X

Concept of the 650 MHz cavities for the Project X is presented. Choice of the basic parameters, i.e., number of cells, geometrical {beta}, apertures, coupling coefficients, etc., is discussed. The cavity optimization criteria are formulated. Results of the RF design are presented for the cavities of both the low-energy and high-energy sections.

43 PARTICLE ACCELERATORS↗

High power couplers for Project X

Project X, a multi-megawatt proton source under development at Fermi National Accelerator Laboratory. The key element of the project is a superconducting (SC) 3GV continuous wave (CW) proton linac. The linac includes 5 types of SC accelerating cavities of two frequencies.(325 and 650MHz) The cavities consume up to 30 kW average RF power and need proper main couplers. Requirements and approach to the coupler design are discussed in the report. New cost effective schemes are described. Results of electrodynamics and thermal simulations are presented.

43 PARTICLE ACCELERATORS↗

Cavity loss factors of non-relativistic beams for Project X

Cavity loss factor calculation is an important part of the total cryolosses estimation for the super conductive (SC) accelerating structures. There are two approaches how to calculate cavity loss factors, the integration of a wake potential over the bunch profile and the addition of loss factors for individual cavity modes. We applied both methods in order to get reliable results for non-relativistic beam. The time domain CST solver was used for a wake potential calculation and the frequency domain HFSS code was used for the cavity eigenmodes spectrum findings. Finally we present the results of cavity loss factors simulations for a non-relativistic part of the ProjectX and analyze it for various beam parameters.

43 PARTICLE ACCELERATORS↗

A proof-of-principle experiment of the ferroelectric tuner for the 1.3 GHz gun cavity

A novel ferroelectric frequency tuner was developed by the Ornega-P company and was tested at the Brookhaven National Laboratory on a 1.3 GHz RF cavity at room temperature. The tuner is based on the ferroelectric property of having a permittivity variable with an applied electric field. The achievable frequency tuning range can be estimated from the reactive impedance change due to an applied voltage via a S{sub 11} measurement at the tuner port. The frequency shift can be measured directly with a S{sub 21} measurement across the gun cavity with the tuner connected and activated. The frequency change due to an applied 5 kV obtained from the two methods is in reasonable agreement. The reactive impedance measurement yields a value in the range between 3.2 kHz and 14 kHz, while 9 kHz is the result from the direct measurement. The detail description of the experiment and the analysis will be discussed in the paper.

43 PARTICLE ACCELERATORS↗

Low Beam Voltage, 10 MW, L-Band Cluster Klystron

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

43 PARTICLE ACCELERATORS↗