Ke, Li

Publications and source records attributed to Ke, Li.

Optical properties of implanted Xe color centers in diamond

Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. Here in this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at 794 nm and 811 nm, which can be effectively excited using both green and red excitation, however, its emission in the nitrogen rich diamond is brighter. Near resonant excitation is performed at cryogenic temperatures and luminescence is probed under strong magnetic field. Finally, our results are important towards the understanding of the Xe related defect and other near infrared color centers in diamond.

36 MATERIALS SCIENCE↗

Small angular displacement measurement based on an autocollimator and a common-path compensation principle

A novel method for small angular displacement measurement based on an autocollimator and a common-path compensation principle by using single CCD detector was proposed. The principles of the angular displacement measurement and the common-path compensation were analyzed. The feasibility of measurement method was verified and the experimental results revealed that the linear correlativity between the relative displacement of the measuring beam spot and the angular displacement is 0.99996. And the measurement resolution is about 0.03 arcsec. To test the compensation's effect, a series of experiments introducing three different interferences from system and external environment were performed. The experimental results indicated that the standard deviations of the measuring beam spot's angular drift were improved by at least 25.0% to at most 80.0% in x direction while by at least 28.2% to at most 95.6% in y direction. Thus, the stability of the system and the measurement resolution were improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping

Purpose: The purpose of this work is to demonstrate that multicontrast computed tomography (CT) imaging can be performed using a Talbot-Lau interferometer without phase stepping, thus allowing for an acquisition scheme like that used for standard absorption CT. Methods: Rather than using phase stepping to extract refraction, small-angle scattering (SAS), and absorption signals, the two gratings of a Talbot-Lau interferometer were rotated slightly to generate a moire pattern on the detector. A Fourier analysis of the moire pattern was performed to obtain separate projection images of each of the three contrast signals, all from the same single-shot of x-ray exposure. After the signals were extracted from the detector data for all view angles, image reconstruction was performed to obtain absorption, refraction, and SAS CT images. A physical phantom was scanned to validate the proposed data acquisition method. The results were compared with a phantom scan using the standard phase stepping approach. Results: The reconstruction of each contrast mechanism produced the expected results. Signal levels and contrasts match those obtained using the phase stepping technique. Conclusions: Absorption, refraction, and SAS CT imaging can be achieved using the Talbot-Lau interferometer without the additional overhead of long scan time and phase stepping.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography

Purpose: The noise variance versus spatial resolution relationship in differential phase contrast (DPC) projection imaging and computed tomography (CT) are derived and compared to conventional absorption-based x-ray projection imaging and CT. Methods: The scaling law for DPC-CT is theoretically derived and subsequently validated with phantom results from an experimental Talbot-Lau interferometer system. Results: For the DPC imaging method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both in theory and experimental results, in DPC-CT the noise variance scales with spatial resolution following an inverse linear relationship with fixed slice thickness. Conclusions: The scaling law in DPC-CT implies a lesser noise, and therefore dose, penalty for moving to higher spatial resolutions when compared to conventional absorption-based CT in order to maintain the same contrast-to-noise ratio.

60 APPLIED LIFE SCIENCES↗

Matter-Wave Self-Imaging by Atomic Center-of-Mass Motion Induced Interference

We demonstrate matter-wave self-imaging resulting from atomic center-of-mass motion-based interference. We show that non-negligible atomic center-of-mass motion and an instantaneous Doppler shift can drastically change the condensate momentum distribution, resulting in a periodic collapse and the recurrence of condensate diffraction probability as a function of the stationary light-field pulsing time. The observed matter-wave self-imaging is characterized by an atomic center-of-mass motion induced population amplitude interference in the presence of the light field that simultaneously minimizes all high (n{>=}1) diffraction orders and maximizes the zeroth diffraction component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal estimation of an unknown maximally entangled state with local operations and classical communication

We consider the optimal measurement procedures for estimating an unknown maximally entangled state with local operations and classical communications (LOCC). By the 'optimal', we mean that there is no other LOCC measurements that can provide a higher estimation fidelity. In fact, we first use the positive partial transpose constraint to obtain an upper bound of the fidelity; then, we show there exists a kind of LOCC measurement that can attain such a bound. The estimation fidelity of the optimal LOCC estimation procedures is (D+2/(D+1)D{sup 2}) with D denoting the dimension of the relevant quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limitation of decoy-state Scarani-Acin-Ribordy-Gisin quantum-key-distribution protocols with a heralded single-photon source

For the Bennett-Brassard 1984 (BB84) quantum key distribution, longer distance and higher key generating rate is shown with a heralded single-photon source (HSPS) [Phys. Rev. A. 73, 032331 (2006)]. In this paper, the performance of the Scarani-Acin-Ribordy-Gisim (SARG) protocol utilizing the HSPS sources is considered and the numerical simulation turns out that still a significant improvement in secret key generating rate can also be observed. It is shown that the security distance for HSPS+SARG is 120 km. However, compared with the HSPS+BB84 protocols, the HSPS+SARG protocol has a lower secret key rate and a shorter distance. Thus we show the HSPS+BB84 implementation is a preferable protocol for long distance transmittance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗