Search NASA⌕ Search

Engineering topics

Kelley, R. L.

Publications and source records attributed to Kelley, R. L..

At least 91 records · Page 5

X ray microcalorimeters: Principles and performance

Microcalorimeters operating at cryogenic temperatures can be excellent X-ray spectrometers. They simultaneously offer very high spectral resolving power and high efficiency. These attributes are important for X-ray astronomy where most sources have low fluxes and where high spectral resolution is essential for understanding the physics of the emitting regions. The principles of operation of these detectors, limits to their sensitivity, design considerations, techniques of fabrication, and their performance as X-ray spectrometers, are reviewed.

Moseley, S. H.↗

Thermal detectors for X-ray astronomy - Current performance and limitations

We have been developing thermal detectors for X-ray astronomy. These detectors have the advantages of both high energy resolution and high quantum efficiency. A practical detector operating at a temperature of 0.1 K could ideally have a resolution as good as 1 eV (FWHM). We have produced a detector with a measured resolution of 7 eV (FWHM) for 6 keV X-rays. The detailed behavior of the detector thermistor and thermal links impose limits on performance. Techniques for improving detector behavior will be discussed. We are currently constructing an instrument for launch on a sounding rocket to observe the soft X-ray emission from the interstellar medium.

Juda, M.↗

Detection of coherent 7.6 Hz oscillations during a burst from Aquila X-1

The results are reported of timing and spectral analysis of the X-ray source Aql X-1 (X1908 + 005) using data obtained with the Einstein SSS and MPC instruments. A classic type I burst was observed from Aql X-1 in both detectors, and a coherent modulation with a period of 131.66 + or - 0.02 (7.6 Hz) and a pulsed fraction of 10 percent was detected in the SSS data (0.64-4.5 keV) during the period of enhanced emission. The signal has a random occurrence probability of less than 5 x 10 to the -5th. The sensitivity of the MPC for high-resolution timing during the burst is greatly reduced because of the low-duty cycle during the burst, and the modulation is not detected. There is no evidence for a loss of coherence during the 80 s or so when it is observable. It is argued that an asymmetrical burst occurring on a neutron star rotating at 7.6 Hz offers a plausible explanation for the oscillation.

Schoelkopf, R. J.↗

Einstein SSS and MPC observations of Aql X-1 and 4U1820-30

The results of timing and spectral analyses of the X-ray sources Aql X-1 (X1908+005) and 4U1820-30 (NGC6624) are reported using data obtained with the Einstein SSS (Solid State Spectrometer) and MPC (Monitor Proportional Counter) instruments. A classic type I burst was observed from Aql X-1 in both detectors and a coherent modulation with a period of 131.66 + or - 0.02 ms and a pulsed fraction of 10 percent was detected in the SSS data. There is no evidence for a loss of coherance during the approximately 80 sec when the burst is observable. The 2 sigma upper limit on the rate of change of the pulse period is 0.00005s/s. It is argued that an asymmetrical burst occurring on a neutron star rotating at 7.6 Hz offers a plausible explanation for the oscillation. The data from 4U1820-30 show that the amplitude of the 685 sec modulation, identified as the orbital period, is independent of energy down to 0.6 keV. The SSS data show that the light curve in the 0.6 to 4.5 keV band is smoother than at higher energies.

Kelley, R. L.↗

MOXE: An X-ray all-sky monitor for Soviet Spectrum-X-Gamma Mission

A Monitoring Monitoring X-Ray Equipment (MOXE) is being developed for the Soviet Spectrum-X-Gamma Mission. MOXE is an X-ray all-sky monitor based on array of pinhole cameras, to be provided via a collaboration between Goddard Space Flight Center and Los Alamos National Laboratory. The objectives are to alert other observers on Spectrum-X-Gamma and other platforms of interesting transient activity, and to synoptically monitor the X-ray sky and study long-term changes in X-ray binaries. MOXE will be sensitive to sources as faint as 2 milliCrab (5 sigma) in 1 day, and cover the 2 to 20 KeV band.

Priedhorsky, W.↗

MOXE - An X-ray all-sky monitor for the Soviet Spectrum-X-Gamma mission

A Monitoring X-Ray Equipment (MOXE) is being developed for the Soviet Spectrum-X-Gamma Mission. MOXE is an X-ray all-sky monitor based on array of pinhole cameras, to be provided via a collaboration between Goddard Space Flight Center and Los Alamos National Laboratory. The objectives are to alert other observers on Spectrum-X-Gamma and other platforms of interesting transient activity, and to synoptically monitor the X-ray sky and study long-term changes in X-ray binaries. MOXE will be sensitive to source as faint as 2 milliCrab (5 sigma) in 1 day, and cover the 2 to 20 KeV band.

Priedhorsky, W.↗

Progress in kinetic inductance thermometers for X-ray calorimeters

Conventional X-ray microcalorimeters have so far used ionimplanted resistors for thermometers. Recently, however, several new methods for sensing small temperature changes have been suggested that are nondissipative. Such devices may have intrinsically better energy resolution by eliminating the Johnson noise present in resistive devices. The use of kinetic inductance thermometers for X-ray microcalorimeters is being investigated. This technique exploits the strong temperature dependence of magnetic penetration depth of thin superconducting films. The prototype system, designed for operation at 1.5 K, uses films of aluminum and tin. Once the expected temperature sensitivity and alpha particle detection have been demonstrated, aluminum will be replaced with titanium or another material with a suitable critical temperature and the device will be operated at 0.3 K. At this temperature, the energy resolution from thermal noise should be sufficiently good to allow X-ray detection.

Rawley, G. L.↗

Long-term temporal variability of Cygnus X-2

Observations of the low-mass binary X-ray source Cyg X-2 taken over a five-year period using instruments on OSO 8, HEAO 1, and Einstein are presented. Irregular changes in intensity of up to 60 percent on time scales ranging from minutes to days are seen. The source appears to have long-term low-luminosity states during which dips lasting about three days occur. When these long dips occur, they always appear at the same phase in the optically determined 9.8-day orbital period. There are three distinct types of short-term dips distinguished by differing correlations between spectral hardness and intensity.

Vrtilek, S. D.↗

Advances toward high spectral resolution quantum X-ray calorimetry

Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

Moseley, S. H.↗

High resolution X-ray spectroscopy using microcalorimeters

The use of microcalorimeters for high-resolution, high quantum efficiency, nondispersive X-ray spectroscopy has been demonstrated over the past few years. In this paper, the principles of X-ray calorimetry are reviewed, and the results of ongoing X-ray tests using microcalorimetry are summarized. An approach to building an X-ray calorimeter spectrometer is discussed.

Kelley, R. L.↗

Orbital elements of the binary X-ray pulsar GX 301-2

X-ray outbursts from GX 301-2 were observed with Hakucho on two occasions during April and May 1982 and with Tenma in April 1984. Pulse arrival times measured with Hakucho were combined with those previously measured with Ariel 5 and SAS 3. The joint timing analysis of these data sets yields an orbital period of 41.5 days as the only acceptable solution; this is consistent with the period derived from the X-ray flaring events of the source. The orbital elements of the binary system, established from the joint timing analysis, are presented. The orbital solution suggests that all the peaks of X-ray flares observed during the past 10 yr occur at the orbital period, but consistently appear about 1.4 days before the time of periastron passage of the X-ray star.

Sato, N.↗

Thermal detectors for high resolution spectroscopy

Cryogenic microcalorimeters can be made sensitive enough to measure the energy deposited by a single particle or X-ray photon with an accuracy of about one electron volt. It may also be possible to construct detectors of several-kilograms mass whose resolution is only a few times worse than this. Data from relatively crude test devices are in good agreement with thermal performance calculations, and a total system noise of 11 eV FWHM has been obtained for a silicon detector operating at 98 mK. Observations of 35 eV FWHM for 6-keV X-rays with a different device have been made.

Mccammon, D.↗

The GSFC/Wisconsin X-ray spectroscopy investigation for AXAF

A novel device is described which combines the high quantum efficiency of a photoelectric detector with the high energy resolution of a dispersive spectrometer in a system that operates simultaneously over the whole AXAF bandpass. It is basically an X-ray calorimeter, in which the temperature rise of an X-ray absorber following the deposition of energy from a single X-ray photon can be measured to an accuracy expected to be of order one part in 1000 at 6 keV.

Holt, S. S.↗

Thermal detectors as single photon X-ray spectrometers

In a thermal detector employed for X-ray spectroscopy applications, the energy of an X-ray is converted to heat in a small mass, and the energy of that X-ray inferred from the size of the temperature rise. The present investigation is concerned with the possibility to make an extremely low heat capacity calorimeter which can be employed as a thermal detector. Several types of calorimeters were fabricated and tested at temperatures as low as approximately 0.05 K. The obtained devices make use of thermistors constructed of melt-doped silicon, nuclear transmutation doped (NTD) germanium, and ion-implanted silicon with a variety of materials for the support and electrical leads. The utility of these microcalorimeters as X-ray spectrometers could be verified.

Moseley, S. H.↗

Discovery of 9.3 s X-ray pulsations from 2S 1553-542 and a determination of the orbit

X-ray pulsations with a period of 9.3 s from the transient galactic X-ray source 2S 1553-542 were detected. The data were obtained with SAS 3 during the only known outburst of the source in 1975 June. Pulse-timing analyses of the data, which span an interval of 20 days, show that there were large changes in the pulse period that are readily attributable to binary orbital motion. The inferred orbital period is 30.6 + or - 2.2 days and the X-ray mass function is 5.0 + or - 2.1 solar masses. These orbital parameters, the transient nature of the source, and the probable lack of an early-type giant companion star, lead to the tentative conclusion that 2S 1553-542 is a Be/X-ray binary system.

Kelley, R. L.↗

Orbital period changes in Centaurus X-3

Two new times of mid-X-ray eclipse for Cen X-3 are presented on the basis of pulse arrival time analyses of pointed observations with SAS 3. When combined with all other published eclipse times based on Doppler delay measurements, the results show that the 2.1d binary period is decreasing at an average rate of 1.8 x 10 to the -6th/yr. The decrease, however, is seen as having significant fluctuations about a smooth, linear decrease. The changes observed in the orbital period can be accounted for by mass loss from the system through the L2 point, although the rates required are implausibly high. It is also shown that the long-term overall orbital decay can readily be interpreted as the result of torques exerted by the tidally distorted companion star (Krzeminski's star) on the orbiting neutron star. It is noted that the inferred asynchronism between the orbital frequency and the rotation frequency of the companion star may be maintained by mass and angular momentum loss in a stellar wind or by a tidal instability related to the Darwin effect. However, this would not provide a natural explanation for any short-term deviations from a constant rate of orbital decay.

Kelley, R. L.↗

Discovery of 13.5 s X-ray pulsations from LMC X-4 and an orbital determination

X-ray pulsations with a 13.5-sec period have been detected from the 1.4-d X-ray binary LMC X-4. By measuring the apparent pulse period at several binary orbital phases, and assuming the orbit to be nearly circular, the semimajor axis of the orbit is determined to be 30 + or - 5 ly-sec. This result, together with a revised orbital velocity amplitude of 37.9 + or - 2.4 km/sec, and other available information, suffice for the determination of the component masses of the binary system and the radius of the companion star. The mass of the neutron star is found to be 1.6 +1.0 -0.5 solar masses, while the mass, radius, and effective temperature of the companion star indicate that it may be undermassive for its luminosity.

Kelley, R. L.↗

A search for apsidal motion in 4U0115+63

The measurement of apsidal motion provides one of the few experimental tests of models of stellar interiors. Binary X-ray pulsars are suited for a potentially important application of the apsidal motion test because of their generally close orbits and the precision with which their orbits can often be measured. The orbit of the X-ray pulsar 4U0115+63 was determined by Rappaport et al. (1978). The orbital parameters were determined with sufficient precision to make possible a measurement of apsidal motion if a second observation of the source could be made. However, 4U0115+63 has not been observed to be active since its 1978 outburst. An analysis has, therefore, been conducted of the archival Uhuru data of the first recorded outburst of this source in early 1971. The results of this analysis are combined with the 1978 observations. It is concluded that apsidal motion would have been detectable if the companion were a rapidly rotating star with a mass not less than 30 solar masses.

Kelley, R. L.↗