Optimizing Transition-Edge Sensor Design for High Count-Rate Applications

We are developing transition-edge sensor (TES) X-ray detectors optimized for high count-rate applications. These devices are fabricated on thick (300 {mu}m) Si substrates, resulting in a 20 times increase in thermal conductance to the heat sink compared to our conventional membrane isolated TES's. Operating a TES with higher heat sink conductance requires 4.5 times more bias current. This results in a 2.7 times increase in {beta}, the logarithmic derivative of resistance with respect to current. Noise measurements show a lower limit on the TES excess noise scales as (2{beta}){sup 1/2}, consistent with the near-equilibrium, non-linear expansion of the Ohmic Johnson noise. This is consistent with our membrane devices though the increased {beta} means the theoretical best attainable resolution is degraded by 25-35%. We have tested devices with different contact geometries between the absorber, and the TES and substrate. This allows us to investigate the loss of athermal phonons to the substrate, which can degrade the resolution. Results show a correlation between the stem contact area and a low-energy tail in the spectral response at 5.9 keV due to the athermal phonon loss. In several devices tested we demonstrate a resolution of 4.1-5.6 eV, coupled with detector time constants as fast as 44 {mu}s, representing an increase in detector response by 7 times compared to the membrane devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Results and Modeling of Low-Heat-Capacity TES Microcalorimeters for Soft-X-ray Spectroscopy

Transition-edge-sensor (TES) X-ray microcalorimeters have mostly been targeted at mid-band energies from 0.05-10 keV and high energies to above 100 keV. However, many other optimizations are possible. Here we present results from devices optimized for soft X-ray applications. For spectroscopy below 1 keV, the X-ray stopping power and heat capacity (C) of the TES itself are high enough that we can omit a separate absorber. The resulting devices have low C and the best-achievable energy resolution should be under 1 eV. We are interested in pursuing such devices primarily for astrophysical applications and laboratory astrophysics at LLNL's Electron-Beam Ion Trap. To this end, we have studied arrays in which 'bare' TESs are interspersed with broad-band pixels that have absorbers. By extending the absorbers to cover the area where the leads contact the low-energy pixels, we have eliminated a significant source of non-Gaussian detector response. The bare devices are in a different regime from our typical devices in that C is ten times lower and the conductance to the bath is four times lower. We have explored this regime through simultaneous fitting of noise and impedance data. These data cannot be fit by the simple model we employ to describe our typical broad-band devices. In this contribution we present X-ray spectra and the results from modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Astro-H Soft X-ray Spectrometer (SXS)

The Soft-X-ray Spectrometer (SXS) is a high spectral resolution, cryogenic x-ray spectrometer that will fly on the Japan/U.S. Astro-H observatory in 2014. The SXS is composed of a 36 pixel, imaging, x-ray calorimeter array that will operate at 0.05 K utilizing a 2-stage adiabatic demagnetization refrigerator and a redundant pre-cooler design using both a 40 liter liquid helium tank and a 1.7 K Joule-Thomson (JT) cryocooler. Additional redundant Stirling cycle coolers provide pre-cooling for the (JT) and cool the outer thermal shields for the JT and the helium tank. The detector system, while similar to that flown on Suzaku, is composed of larger 0.81x0.81mm pixels, but has significantly better performance, currently predicted to be better than 4 eV FWHM at 6 keV with 95% quantum efficiency. This instrument is the result of a close collaboration between many institutions in the U.S. and Japan over the last 25 years. Here we will present an overview of the SXS instrument, the SXS cooling system, and recent laboratory improvements to the detector system.0.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Measurement of the K-Shell Spectrum from Highly Charged Xenon with an Array of X-Ray Calorimeters

We present a measurement of the K-shell spectrum from highly charged xenon ions recorded with a high-energy x-ray calorimeter spectrometer array that can distinguish between various theories for the atomic structure of the two electron system. The array was designed to provide high resolution with high quantum efficiency in the 10-60 keV x-ray range which allows us to resolve blends that afflicted previous measurements. A precision of better than 2 eV was achieved in the measurement of the Xe{sup 52+} and Xe{sup 53+} K-shell transitions located near 31 keV, which is an order of magnitude better than previously reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗