Search NASASearch

Engineering topics

Kellogg, E. M.

Publications and source records attributed to Kellogg, E. M..

At least 19 records

Dynamic Evolution in the Symbiotic R Aquarii

We report on multiple Chandra observations spanning a period of 5 years as well as a more recent XMM observation of the nearby symbiotic binary R Aqr. Spectral analysis of these four observations reveals considerable variability in hardness ratios and in the strength and ionization levels of emission lines which provides insight into white dwarf accretion processes as well as continuum and line formation mechanisms. Chandra imaging of the central source also shows the formation and evolution of a new south west jet. This growing body of high-resolution X-ray data of R Aqr provides a unique glimpse into white dwarf wind-accretion processes and jet formation.

DePasquale, J. M.

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.

Precision of the calibration of the AXAF Engineering Test Article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.

Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation

We are developing a system to calibrate reflectances of witness coupons to the AXAF flight mirrors at the National Synchrotron Light Source over the 0.05-12 keV energy range. These witness coupons will be coated in the same process as the AXAF mirror elements. One of the key issues is the accurate determination of mirror efficiencies across the absorption edges of the mirror coating elements. We present a series of reflectance measurements with 2 eV resolution of a nickel-coated flat mirror in the region of the Ni L-II (870 eV) and L-III (853 eV) absorption edges. Scans of reflectance versus grazing angle at fixed energies in this region show distinct interference fringes at grazing angles larger than the critical angle which are extinguished as the photon energy is increased beyond the low point of the L-III edge, indicating total absorption of the evanescent wave within the Ni film. At 51 arc minutes grazing angle, measured reflectance decreases smoothly by 35 percent and then recovers in an 8 eV band at the L-III edge. We have also measured reflectances in the M absorption edge region for gold, platinum, and iridium coated mirrors. We derive optical parameters n and k specific to the film for comparison to the existing data tables.

Graessle, D. E.

VETA-I x ray test analysis

This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report.

Brissenden, R. J. V.

Feasibility study of the use of synchrotron radiation in the calibration of AXAF - Initial reflectivity results

The 1-percent calibration accuracy goal of the Advanced X-ray Astrophysics Facility is being approached by way of an experiment at the National Synchrotron Light Source that will demonstrate the accuracy achievable in reflectance measurements conducted on coated flat mirrors in the 50 eV-12 keV energy range. The coatings will be of commercially produced Au, Ni, and Ir, deposited either by sputtering or by e-beam deposition. Optical constants will be estimated via the reflectance vs. angle-of-incidence method.

Graessle, D. E.

Primeval gas clouds and the low-energy X-ray background

A model for the appearance of the all-sky low-energy X-ray background on a fine angular scale is presented which is based on primeval hot gas clouds associated with the formation of clusters of galaxies according to the Sunyaev-Zel'dovich (1972) model. It is noted that the background could have both granular and diffuse components if it is due to such gas clouds. The observed appearance of the granular component is predicted along with the observable characteristics of collapsing protoclusters. The effects of distant X-ray-emitting QSOs, radio galaxies, and normal galaxies on the observations are considered, and these sources are shown not to interfere with the possibility of observing the protoclusters. It is concluded that if sufficient heating occurred in an intracluster medium within some clusters of galaxies at the protocluster epoch, the ensemble properties of protoclusters could be observed with an X-ray telescope, and the time at which protoclusters formed could perhaps be estimated.

Kellogg, E. M.

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.

X-ray astronomy in the Uhuru epoch and beyond /Newton Lacy Pierce Prize Lecture/

A review of results from the Uhuru satellite is presented. An intensive treatment of two subjects is given, rather than a broad review. First, Cyg X-1, a stellar X-ray source and a candidate for a black hole, is discussed; second, the X-ray source in the Perseus cluster of galaxies, which may be a cloud of hot intergalactic gas, is treated. In both cases, the train of logic used in establishing the nature of these objects is presented and evaluated. For both, while alternative explanations cannot be completely eliminated, they become more difficult to sustain when examined in detail, suggesting that the candidate explanations are more likely correct.

Kellogg, E. M.

Correlation analysis of X-ray emission from Cygnus X-1

Normalized autocorrelation and cross-correlation coefficients have been calculated for the X-ray emission of Cygnus X-1 in two energy bins, 2.1-5.1 keV and 5.1-12 keV. The analysis shows a strong correlation between the pulsations in the two energy bins, with the low-energy pulsations lagging behind the high-energy ones, or alternatively a shorter duration of the pulse trains in the high-energy bin. The power spectral density derived from the autocorrelation functions indicates a larger contribution of the high-frequency components for the higher-energy X-rays.

Brinkman, A. C.

On the nature of the unidentified high latitude UHURU sources

It is found that the unidentified high latitude UHURU sources can have either of two very different explanations. They must either reside at great distances with luminosity equivalent to or greater than 10 to the 46th power ergs/sec, or be contained in the galaxy with luminosity equivalent to or less than 10 to the 34th power ergs/sec. The two possibilities are indistinguishable with the available data.

Holt, S. S.

Radio stars and X-ray sources.

Limits on the X-ray emission from the known radio stars that can be studied with Uhuru are of interest because of the possible association between X-ray binaries and radio star binaries, and because limits or measurements of the X-ray fluxes can help determine the source of the radio emission. It is shown that if, for the moment, HDE226868 is ignored, none of the radio stars was detected as an X-ray source. It appears that there are two types of radio binary stars, one which is a strong X-ray source and one which is not.

Bahcall, J. N.

Observations of Cygnus X-3 by Uhuru.

Report on the X-ray intensity observations of Cygnus X-3 performed with the aid of the X-ray satellite, Uhuru, before and during the radio flare of early September 1972. An analysis of 32 transits of the source, obtained during the period August 19 to September 6, is presented. There is no indication of an intensity change coincident with the radio flare. It is concluded that whatever precipitated the radio flare did not have a significant impact on the X-ray emitting region. Other characteristics of Cyg X-3 are also discussed.

Parsignault, D. R.

Discovery of a periodic pulsating binary X-ray source in Hercules from Uhuru.

We have discovered a new pulsating X-ray source with a 1.24-sec period in the constellation Hercules. Analysis of 5 months of data has shown the existence of periodic variations in the intensity of the source and correlated sinusoidal variations in the period of the 1.24-sec pulsations. As in the case of the pulsating X-ray source Cen X-3, we interpret this effect as due to an occulting binary system, with the intensity changes due to occultation of the X-ray source by its companion and with the sinusoidal variations in the period of the 1.24-sec pulsations due to the Doppler effect. In addition, we have observed a longer-time scale cycle in which the source is bright and pulsing for approximately 9 days during which we can observe the 1.7-day occulting, followed by approximately 27 days during which the source is not detected above background on individual 20-sec scans.

Tananbaum, H.

A new transient source observed by Uhuru.

A strong X-ray source appeared sometime between March 25 and August 17, 1971. On August 23, its intensity, as observed by the Uhuru satellite, was about twice that of the Crab Nebula, corresponding to about 3 times 10 to the -8th power ergs per sq cm per sec, in the range 2-6 keV. On December 20, 1971, its intensity had declined to one-tenth of that value in the same energy range. Its spectrum was quite steep, and fit a power law with an average energy spectral index of 3.0. The variation of X-ray intensity over a 5-month period shows qualitative differences from the previously observed transient X-ray sources, Cen XR-2 and Cen XR-4.

Matilsky, T. A.

X-ray emission from rich clusters of galaxies.

Evaluation of the newly published Uhuru catalog, revealing significant number of rich clusters associated with X-ray sources. Combined with earlier observations of X-ray emission from the Virgo, Coma, and Perseus clusters, this suggests that most, if not all, rich clusters include an X-ray emission region of large size and of net luminosity from 10 to the 43rd to 10 to the 44th ergs/sec.

Gursky, H.