Search NASASearch

Engineering topics

Kemp, W. B., Jr.

Publications and source records attributed to Kemp, W. B., Jr..

At least 19 records

Wall interference assessment and corrections

Wind tunnel wall interference assessment and correction (WIAC) concepts, applications, and typical results are discussed in terms of several nonlinear transonic codes and one panel method code developed for and being implemented at NASA-Langley. Contrasts between 2-D and 3-D transonic testing factors which affect WIAC procedures are illustrated using airfoil data from the 0.3 m Transonic Cryogenic Tunnel and Pathfinder 1 data from the National Transonic Facility. Initial results from the 3-D WIAC codes are encouraging; research on and implementation of WIAC concepts continue.

Newman, P. A.

Emerging technology for transonic wind-tunnel-wall interference assessment and corrections

Several nonlinear transonic codes and a panel method code for wind tunnel/wall interference assessment and correction (WIAC) studies are reviewed. Contrasts between two- and three-dimensional transonic testing factors which affect WIAC procedures are illustrated with airfoil data from the NASA/Langley 0.3-meter transonic cyrogenic tunnel and Pathfinder I data. Also, three-dimensional transonic WIAC results for Mach number and angle-of-attack corrections to data from a relatively large 20 deg swept semispan wing in the solid wall NASA/Ames high Reynolds number Channel I are verified by three-dimensional thin-layer Navier-Stokes free-air solutions.

Newman, P. A.

Computer simulation of a wind tunnel test section with discrete finite-length wall slots

A computer simulation of a slotted wind tunnel test section which includes a discrete, finite-length wall slot representation with plenum chamber constraints and accounts for the nonlinear effects of the dynamic pressure of the slot outflow jet and of the low energy of slot inflow air was developed. The simulation features were selected to be those appropriate for the intended subsequent use of the simulation in a wall interference assessment procedure using sparsely located wall pressure measurements. It is demonstrated that accounting for slot discreteness is important in interpreting wall pressure measured between slots, and that accounting for nonlinear slot flow effects produces significant changes in tunnel-induced velocity distributions and, in particular, produces a longitudinal component of tunnel-induced velocity due to model lift. A characteristic mode of tunnel flow interaction with constraints imposed by the plenum chamber and diffuser entrance is apparent in simulation results and is derived analytically through a simplified analysis.

Kemp, W. B., Jr.

User's guide to STIPPAN: A panel method program for slotted tunnel interference prediction

Guidelines are presented for use of the computer program STIPPAN to simulate the subsonic flow in a slotted wind tunnel test section with a known model disturbance. Input data requirements are defined in detail and other aspects of the program usage are discussed in more general terms. The program is written for use in a CDC CYBER 200 class vector processing system.

Kemp, W. B., Jr.

Wall-interference assessment in three-dimensional slotted-wall wind tunnels

The development of the slotted tunnel simulator code and lessons learned from its use are summarized. The high order panel method was selected as the basic procedure for aerodynamic computations. The panel singularities are supplemented by line sources to represent discrete wall slots.

Kemp, W. B., Jr.

TWINTN4: A program for transonic four-wall interference assessment in two-dimensional wind tunnels

A method for assessing the wall interference in transonic two-dimensional wind tunnel tests including the effects of the tunnel sidewall boundary layer was developed and implemented in a computer program named TWINTN4. The method involves three successive solutions of the transonic small disturbance potential equation to define the wind tunnel flow, the equivalent free air flow around the model, and the perturbation attributable to the model. Required input includes pressure distributions on the model and along the top and bottom tunnel walls which are used as boundary conditions for the wind tunnel flow. The wall-induced perturbation field is determined as the difference between the perturbation in the tunnel flow solution and the perturbation attributable to the model. The methodology used in the program is described and detailed descriptions of the computer program input and output are presented. Input and output for a sample case are given.

Kemp, W. B., Jr.

A slotted test section numerical model for interference assessment

A numerical model of a slotted wind tunnel test section, intended for use with sparsely measured wall pressures in a wall interference assessment procedure, is described. The numerical model includes a discrete finite length wall slot representation and accounts for the nonlinear effects of the dynamic pressure of the slot outflow jet and of the low energy of slot inflow air. By using th numerical model in a wall interference prediction mode, it is demonstrated that accounting for slot discreteness is important in interpreting wall pressures measured between slots, and that accounting for finite slot length and nonlinear effects in the slot boundary condition can yield significant departures from the wall interference predicted using the classical linear homogeneous infinite-length wall representation.

Kemp, W. B., Jr.

An inerference assessment approach for a three-dimensional slotted tunnel with sparse wall pressure data

The various procedures referred to as wall interference assessment and correction procedures presume the existence of a surface distribution of data (usually static pressure) measured over a surface on or near the tunnel walls for each test point to be assessed. An alternative approach in which a reasonably sophisticated computer model of the test section flow would be fitted parametrically to a sparse set of measured data is presented. The measurements provides line distributions of static pressure near the center lines of the top, side and bottom walls. The development of a test section model incorporating explicit recognition of discrete slots of finite length with controlled flow reentry into the solid wall downstream portion of the tunnel is shown.

Kemp, W. B., Jr.

Adaptation of a four-wall interference assessment/correction procedure for airfoil tests in the 0.3-m TCT

Based upon limited, initial observations of wall interference corrections obtained for one airfoil test, there is a need for assessing the upstream flow direction. If there is no direct measurement then a two-pass correction procedure similar to the one described here is required. Questions have arisen pertaining to the correct interpretation of the pressure coefficients measured on the slats of a slotted tunnel wall, the interpretation of just what the calculated equivalent body encompasses or should include, and what can or should be considered as quantitative criteria for data correctability. Further studies using this modified procedure will address these questions. Hopefully, a meaningful WIAC procedure can be validated for the airfoil tests in the 0.3-m TCT.

Gumbert, C. R.

Combined four-wall interference assessment in two-dimensional airfoil tests

Two different procedures are examined for combining the correction method developed by Barnwell and Sewall for the effects of the sidewall boundary layer in two-dimensional wind-tunnel tests with the assessment and correction method due to Kemp for the effects of the upper and lower tunnel walls. One procedure utilizes the similarity transformation defined by Sewall to eliminate velocity perturbations induced by the sidewall boundary layer from consideration in the assessment and correction method as sources of error. The other procedure combines perturbations from all four walls before assessment and correction. In general, the two procedures yield different corrections to Mach number and angle of attack, either of which can be considered valid. Pressure distributions corrected for higher order interference effects are provided by either procedure.

Kemp, W. B., Jr.

Wall interference effects: Status review

The interference technology incorporated into the NTF design (hardware) and the emerging transonic wall interference assessment correction procedures (software) to be employed when the NTF becomes operational was reviewed. It is anticipated that the early experiments will provide data relevant to wall interference effects.

Newman, P. A.

TWINTAN: A program for transonic wall interference assessment in two-dimensional wind tunnels

A method for assessing the wall interference in transonic two dimensional wind tunnel test was developed and implemented in a computer program. The method involves three successive solutions of the transonic small disturbance potential equation to define the wind tunnel flow, the perturbation attriburable to the model, and the equivalent free air flow around the model. Input includes pressure distributions on the model and along the top and bottom tunnel walls which are used as boundary conditions for the wind tunnel flow. The wall induced perturbation fields is determined as the difference between the perturbation in the tunnel flow solution and the perturbation attributable to the model. The methodology used in the program is described and detailed descriptions of the computer program input and output are presented. Input and output for a sample case are given.

Kemp, W. B., Jr.

A vector-continuous loading concept for aerodynamic panel methods

An approach to the reduction of discretization errors in aerodynamic panel methods is presented. The approach is based on preventing the occurence of induced velocity singularities at panel slope discontinuities by maintaining continuity of the velocity jump vector across the panels. The approach was implemented in a two-dimensional incompressible panel method formulation and evaluated by application to several external and internal flow problems. The method is shown to exhibit a second order accuracy trend and to produce smaller errors with velocity component boundary conditions imposed on the real flow than with equipotential boundary conditions imposed on the imaginary flow behind the panels. For flows around airfoil sections with either sharp or blunt trailing edges, the method gives excellent agreement with results from a well developed finite difference method. The method is well behaved and is insensitive to irregularities in panel size distribution.

Kemp, W. B., Jr.

Transonic assessment of two-dimensional wind tunnel wall interference using measured wall pressures

A method is described for assessing wall interference in two dimensional wind tunnels with better realism and accuracy than is achieved with methods based on classical wall interference theory. Measured pressure distributions were imposed as boundary conditions on a nonlinear transonic form of the potential equation to obtain an accurate computational reproduction of the actual tunnel flow. Wall-induced velocity perturbations were then extracted to yield both corrections to the tunnel test conditions and a measure of the adequacy of these corrections to account for tunnel interference. Application of the method to a transonic tunnel with variable porosity walls is illustrated.

Kemp, W. B., Jr.

Transonic wind-tunnel wall interference

A method for analyzing wall interference is described which avoids the assumption of linear superposition of perturbations in extracting the wall induced velocity field. Measurements of pressure distribution on or near the tunnel walls during the actual wind tunnel test, are imposed as boundary values to be matched. Instead of applying wall interference corrections to the wind tunnel data, some property of the wall is adjusted until a calculated interference free criterion is satisfied for each tunnel data point. The mode of operation for the National Transonic Facility, envisioned as a correctable interference transonic tunnel, combines the capability for accurate assessment of wall interference with a limited capability for wall control.

Kemp, W. B., Jr.

Toward the correctable-interference transonic wind tunnel

The concept of a correctable-interference transonic wind tunnel combining a capability for wall-interference assessment with a limited capability for wall control is introduced. Recent progress toward achieving the interference assessment capability is described. The feasibility of using experimentally measured data directly as boundary values for the assessment in lieu of more generally formulated but less accurate wall boundary conditions is demonstrated for two-dimensional subsonic flows. Also, a procedure for transonic analysis of wall interference which leads to a rational definition of the wall-induced perturbation field within the context of nonlinear transonic flow computations is outlined in principle.

Kemp, W. B., Jr.